PXIe Digitizers with Optional Real-Time Sequencing and FPGA Programming

100 MSa/s, 14 Bits, 4/8 Channels

02 | Keysight | M3100A PXIe Digitizer with Optional Real-Time Sequencing and FPGA Programming - Data Sheet Improve Your Measurement Fidelity, Signal Integrity and Measurement Throughput The M3102A are high-performance, high-bandwidth digitizers with an advanced data acquisition system (DAQ). Performance meets simplicity thanks to easy-to- use programming libraries, real-time sequencing technology (HVI Hard Virtual Instrumentation), and graphical FPGA programming technology.

Features

100 MSa/s simultaneous sampling, 14 bits, 4/8 channels, 100 MHz BW √

Advanced data acquisition system (DAQ) – Flexible triggering (HW trigger, HVI trigger, SW trigger) – Programmable cycles and data bursts to avoid PC saturation Optional HW programming for high-performance applications – Real-time sequencing (HVI technology) – FPGA programming – Xilinx Kintex-7, 325T or 410T FPGA Up to 2 GB of onboard RAM (~ 1 Gsamples) Mechanical/interface – 1 slot 3U (PXIe) – Up to 1.6 GB/s transfer BW with P2P capabilities (PCIe Gen 2) – Independent DMA channels for fast and efficient data transfer

Applications

Hardware-in-the-loop (HIL)/automated test equipment (ATE) R&D/scientific research equipment Aerospace & defense (A/D) √ 100 MHz refer to the Front End bandwidth. This digitizer can operate in 1st and 2nd Nyquist zones (using undersampling technique), but its real-time BW is limited by Nyquist to some 50 MHz. As an example for a band-limited signal of 70 MHz with a 10 MHz signal bandwidth the aliased component will appear between 25 to 35 MHz (30 ± 5 MHz).

03 | Keysight | M3100A PXIe Digitizer with Optional Real-Time Sequencing and FPGA Programming - Data Sheet Programming technology and software tools Software programming – Easy-to-use native programming libraries for most common languages: C, C++, Visual Studio, LabVIEW, MATLAB, Python, and more Hardware programming (optional) – Real-time sequencing (Hard Virtual Instrumentation or HVI technology) – Graphical flowchart-style M3601A design environment (-HV1 option required on HW) – Ultra-fast, fully-parallelized hard real-time execution – Ultra-fast, time-deterministic decision-making – Off-the-shelf inter-module synchronization & data exchange – FPGA programming – Graphical M3602A FPGA design environment (-FP1 option required on HW) – No FPGA know-how required – Include high-level to low-level design elements: off-the-shelf DSP blocks, MATLAB/ Simulink designs, Xilinx CORE Generator IP cores, Xilinx VIVADO/ISE projects, VHDL or Verilog code – Ultra-fast, one-click compiling and on-the-fly programming No programming – Ready-to-use SD1 SPF (software front panels) M31XX/M32XX/M33XX family product table Product Type Outputs (AWGs) Inputs (Digitizers) Speed (MSa/s) Bits Ch BW (MHz) Speed (MSa/s) Bits Ch BW (MHz) M3202A AWG 1000 14 2/4 DC-400 M3201A AWG 500 16 2/4 DC-200 M3102A Digitizer 500 14 2/4 DC-200 M3100A Digitizer 100 14 4/8 DC-100 M3302A Combo 500 16 2 DC-200 500 14 2 DC-200 M3300A Combo 500 16 2/4 DC-200 100 14 4/8 DC-100

04 | Keysight | M3100A PXIe Digitizer with Optional Real-Time Sequencing and FPGA Programming - Data Sheet Functional block diagram Figure 1. M3100A input functional block diagram, all channels have identical input structure

Ordering information

M3100A PXIe digitizer: 100 MSa/s, 14 Bits Options Description M3100A-CH4 / -CH8 √ Four channels / eight channels M3100A-CLF √ Fixed sampling clock, low jitter M3100A-M01 / -M12 / -M20 √ Memory 16 MB, 8 MSamples / 128 MB, 60 MSamples / 2 GB, 1 GSamples HW programming options Description M3100A-HVI Enabled HVI programming, requires an HVI design environment license (M3601A) M3100A-FP1 Enabled FPGA programming, requires -K32 or -K41 option and an FPGA design environment license (M3602A) M3100A-K32 / -K41 FPGA, Xilinx 7K325T / 7K410T, required for -FP1 option only (needs memory option -M20) All options must be selected at time of purchase and are not upgradable √ These options represent the standard configuration Related software Description M3601A HVI design environment M3602A FPGA design environment Channel 1 Channel x Channel 1 output Data acquisition (DAQx) Full scale, Z, coupling (as available) Prescaler Analog trigger Channel x output Channel n Input settings Channel n output

  1. Markers available from firmware version v3.0 or later

Table 1. General specifications

06 | Keysight | M3100A PXIe Digitizer with Optional Real-Time Sequencing and FPGA Programming - Data Sheet I/O specifications Analog input characteristics Number of channels CH4 or CH8 Sampling rate 100 MSa/s option CLF Configurable inputs: impedance 50Ω or 1 MΩ (HiZ) Configurable inputs: Coupling AC or DC Input voltage range (50Ω) 400 mVpp to 6Vpp (continue: variable attenuator at input) Input voltage range (HiZ) 200 mVpp to 20Vpp (continue: variable attenuator at input) Bandwidth limit filters 100 MHz Effective number of bits (ENOB) 1 10.8 bits @30MHz (typical) Noise floor −142 dBm/Hz @30 MHz (typical) SINAD 67 dB @30 MHz (typical) Spurious free dynamic range (SFDR) + Total Harmonic Distorsion 79 dBc (typical) 1. measured at -1 DBFS input signal with 1.5 Vpp 50Ω Table 2a. M3100A Parameter Min Typ Max Units Comments Reference clock output Frequency 10 or 100 MHz Generated from the internal clock. User selectable Voltage 800 mVpp On a 50 Ω load Power 2 dBm On a 50 Ω load Source impedance 50 Ω AC coupled External I/O trigger/marker VIH 2 5 V VIL 0 0.8 V VOH 2.4 3.3 V On a high Z load VOL 0 0.5 V On a high Z load Input impedance 10 K Ω Source impedance TTL – Speed 500 Mbps Table 2b.

Table 3. Data acquisition blocks (DAQs) specifications Table 4. Clock system specifications Table 5. Environmental specifications (PXI Express)

Cet appareil ISM est conforme à la norme NMB-001 du Canada. Table 6. Environmental

09 | Keysight | M3100A PXIe Digitizer with Optional Real-Time Sequencing and FPGA Programming - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, February 16, 2017 5992-1806EN www.keysight.com For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-11-29-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Services www.keysight.com/find/service Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system.