Model No. LS013B7DH01 Notice Liquid Crystal Display Group SHARP CORPORATION No. LCP-2110019B Date 16th Aug 2010 The technical Literature is subject to change without any prior notice for the purpose of product improvement. Please contact Sharp or its representative before designing your product based on this literature.

REF.PAGE PARAGRAPH DRAWING No. REVISED No. SUMMARY 1st July 2010 First issue P7 Table3-1 Weight was filled in. (Mass: 3.0g) P14 Table6-4 Power consumption of condition1 typ and condition2 typ were added. P 1 9 6-5-5 COM Inversion EXTMODE="H" mode of ※1 : The description of LC inversion polarity was corrected. 16th Aug 2010 P 2 3 8-1) Outline dimension B The black mask shape and size was revised.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE NOTICE <<Precautions>> ○ These specification sheets are the proprietary prod uct of SHARP CORPORATION ("SHARP") and include materials protected under copyright of SHARP. Do not reproduce or cause any third party to reproduce them in any form or by any means, electronic or mechanical, for any purpose, in w hole or in part, without the express written permission of SHARP. ○ The application examples in these spec ification sheets are provided to explain the representative applications of the device and are not intended to guarantee any industrial prop erty right or other rights or license you to use them. SHARP assumes no responsibility for any problems related to any industrial property right of a third party resulting from the use of the device. ○ SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structures and other contents described herein at any time without notice in orde r to improve design or reliability. Contact SHARP in order to obtain the latest specification sheets before using any SHARP's device. Manufacturing locations are also subject to change without notice. Observe the following points when in using any device in this publication. SHARP takes no responsibility for damage caused by improper use of the devices. The devices in this publication are designed for use in general electronic equipment designs, such as: ・Personal computers ・Office automation ・Telecommunication equipment ・Test and measurement equipment ・Industrial control ・Audio visual and multimedia equipment ・Consumer electronics The appropriate design measures should be taken to ens ure reliability and safety when SHARP's devices are used for equipment such as: ・Transportation control and safety equipment(i.e.,aircraft,trains,automobiles,etc.) ・Traffic signals ・Gas leakage sensor breakers ・Alarm equipment ・Various safety devices etc. ○ SHARP's devices shall not be used for equipment that requires extremely high level of reliability, such as: ・Military and space applications ・Nuclear power control equipment ・Medical equipment for life support ○ SHARP assumes no responsibility for any damage resulting from the use of t he device which does not comply with the instructions and the precautions specified in these specification sheets. ○ Contact and consult with a SHARP sales representative for any questions about this device.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE [For handling and system design] (1) Handle with care as glass is used in this LCD panel. Dropping or contact against hard object may cause cracks or chips. (2) Be careful to handle this LCD panel in order to avoid inju ry yourself by panel\`s edge as this panel is made of glass and might be a sharp edge. (3) Do not scratch the surface of the polarizer as it is easily damaged. (4) Water droplets on the polarizer must be wiped off immedi ately as they may cause color changes, or other defects if remained for a long time. (5)Do not leave the LCD panel in direct sun or under ultraviolet ray. (6) To clean LCD panel surface, wipe cl ean with absorbent cotton or soft cloth. If further cleaning is needed, use IPA (isopropyl alcohol) and wipe cle an lightly on surface only. Do not use or ganic solvents as it may damage the LCD panel terminal area which uses organic material. Also, do not directly touch with finger. When the terminals cleaning are needed, those should be wiped by a soft cloth or a cotton swab without directly touching by hand. (7) Do not expose gate driver, etc. on t he panel (circuit area outside panel display area) to light as it may not operate properly. Design that shields gate driver, etc. from light is required when mounting the LCD module. (8) To avoid circuit failure, do not touch panel terminal area. (9) Support for the LCD panel should be carefully designed to avoid stress that exceeds specification on glass surface. (10) When handling LCD module and assembling them into cabi nets, be noted that storage in the environment of oxidization or deoxidization gas and the use of such materials as reagent, solvent, adhesive, resin, and etc. which generate these gasses, may cause corrosion and discoloration of LCD modules. (11)To avoid picture uniformity failure, do not put a seal or an adhesive material on the panel surface. (12) Do not use chloroprene rubber as it generates chlorine gas and affects reliability in LCD panel connective area. (13) Protective film is attached to the surface of pol arizer on LCD panel to prevent scratches or other damages. Remove this protective film before use. In addition, do not attach the protecti ve film which is removed from LCD module again. When the LCD panel which has the reattached protective film is needed to storage for a long time, the polarizer might have a damage with picture quality failure. (14) Panel is susceptible to mechanical stress and such stress may affect the display. Place the panel on flat surface to avoid stress caused by twist, bend, etc. (15) When transporting LCD panels, secure them in LCD panel tray to avoid mechanical stress. The tray should be conductive to protect LCD panels from static charge. Material used in set or epoxy resin (amine type hardening agent) from packaging, and silicon adhesive (dealcoholized or oxime) all release gas which may affect quality of polarizer. Do confirm compatibility with user materials. (16) As this LCD module is composed electronic circuits, it is sensitive to electrostatic discharge of 200V or more. Handle with care using cautions for the followings: z Operators Operators must wear anti-static wears to prevent electrostatic charge up to and discharge from human body.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE z Equipment and containers Process equipment such as conveyer, soldering iron, working bench and containers may possibly generate electrostatic charge up and discharge. Equipmen t must be grounded through 100Mohms resistance. Use ion blower. z Floor Floor plays an important role in leaking static electricity generated in human body or equipment. If the floor is made of insulated material (such as polymer or rub ber material), such static electricity may charge. Proper measure should be taken to avoid static electricity charge (electrostatic earth: 100Mohms).There is a possibility that the static electricit y is charged to them without leakage in case of insulating floor, so the electrostatic earth:1×108Ω should be made. z Humidity Humidity in work area relates to surface resist ance of the persons or objects that generate electrostatics, and it can be manipulated to prevent electrostatic charge. Humidity of 40% or lower increases electrostatic earth resistance and promotes electrostatic charging. Therefore, the humidity in the work area should be kept ab ove 40%. Specifically for film peeling process or processes that require human hands, humidit y should be kept above 50% and use electricity removal blower. z Transportation/Storage Containers and styroform used in transporation and storage may charge electrostatic (from friction and peeling) or electrostatic charge from human body, etc. may cause containers and styroform to have induced charge. Proper electrostatic measure should be taken for containers and storage material.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE [For operating LCD module] (1) Do not operate the LCD panel under outside of electrical specification. Otherwise LCD panel may be damaged. (2) Do not use the LCD panel under outside of specifi ed driving timing chart. Otherwise LCD panel may not have proper picture quality. (3) A still image should be displayed less than two hours, if it is necessary to display still image longer than two hour, display image data must be refreshed in order to avoid sticking image on LCD panel. (4) If LCD module takes a static electric ity, as the display image which is wr itten into pixel memory might not be displayed, Data update should be executed frequently. (5) It is neither a breakdown nor a defective indication thoug h very slight change in black level might be periodically seen in a black part on the black display image according to the source of light (angle of the luminance and the source of light). [Precautions for Storage] (1) After opening the package, do not leave the LCD panel in direct sun or under strong ultraviolet ray. Store in dark place. (2) In temperature lower than specified rating, liquid crysta l material will coagulate. In temperature higher than specified rating, it isotropically liquifies. In either condi tion, the liquid crystal may not recover its original condition. Store the LCD panel in at or around room temperature as much as possible. Also, storing the LCD panel in high humidity will damage the polarizer. Store in normal room temperature as much as possible. (3) Keeping Method a. Don't keeping under the direct sunlight. b. Keeping in the tray under the dark place.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE [Other Notice] (1) Operation outside specified environment al conditions cannot be guaranteed. (2) As power supply (VDD-GND 、VDDA-GND) impedance is lowered during use, bus controller should be inserted near LCD module as much as possible. (3) Polarizer is applied over LCD panel surface. Liquid cr ystal inside LCD panel deteriorates with ultraviolet ray. The panel should not be left in direct sun or under strong ultraviolet ray for prolonged period of time even with the polarizer. (4) Disassembling the LCD module will cause permanent dam age to the module. Do not disassemble the module. (5) If LCD panel is broken, do not ingest the liquid crystal from the broken panel. If hand, leg, or clothes come in contact with liquid crystal, wash off immediately with soap. (6) ODS (specific chlorofuorocarbon, specific halon, 1-1- 1 trichloroethane, carbon tetrachloride) are not used or contained in material or all production processes of this product. (7) Observe all other precautionary requirement s in handling general electronic components. Discarding liquid crystal modules LCD Panel : Dispose of as glass waste. This LCD module contains no harmful substances. The liquid crystal panel contains no dangerous or harmful substances. This liquid crystal panel contains only an extremely small amount of liquid crystal (approximately 100mg) and therefore it will not leak even if the panel should break. Its median lethal dose (LD50) is greater than 2,000 mg/kg and a mutagenetic (Aims test: negative) material is used.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE

Contents

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 1. Outline This TFT-LCD module is a reflective active-matrix with sli ghtly transmissive memory liquid crystal display module with CG silicone thin film transistor. Module outline is indicated in fig 8-1. 2. Characteristics ・ Transflective panel of white and black ・ 1.26” screen has 144x 168 resolusion. (24192 pixels stripe array) ・ Display control by serial data signal communication. ・ Arbitrary line data renewable. ・ 1bit internal memory for data storage within the panel. ・ Thin, light-weight and compact module with monolithic technology. ・ Super low power consumption TFT panel. ・ Zebra connecter 3. Mechanical Specification Table 3-1 Item Specification unit Screen size 3.2 (1.26”) cm Viewing Area 20.88 (H) × 24.36 (V) mm Dot configuration 144 (H) × 168 (V) Dot Dot pitch 0.145 (H) × 0.145 (V) mm Pixel Array Stripe Array - Outline Dimension Mass 3.0 g Surface Hardness 3H Pencil hardness (Note) Detail dimension and tolerance are shown in fig. 8-1

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 4. Input terminal names and functions Table4-1 Terminal symbol I /O Function Remark

1 TEST1 - Test terminal 【Remark4-1】

2 TEST2 - Test terminal 【Remark4-1】

3 SCLK INPUT Serial clock signal

4 SI INPUT Serial data input signal

5 SCS INPUT Chip select signal

6 EXTCOMIN INPUT External COM inversion signal input (H: enable)

7 DISP INPUT Display ON/OFF signal 【Remark4-3】

8 VDDA POWER Power supply (Analog)

9 VDD POWER Power supply (Digital)

10 EXTMODE INPUT COM inversion select terminal 【Remark4-2】

11 VSS GND GND(Digital)

12 VSSA GND GND(Analog)

13 TEST3 - Test terminal 【Remark4-1】

14 TEST4 - Test terminal 【Remark4-1】

【Remark4-1】Test terminal should be OPEN. 【Remark4-2】When EXTMODE is ”H”, EXTCOMIN signal is enable. When EXTMODE is ”L” ,sirial input flag is enable. “H”mode; connect the EXTMODE toVDD, ”L” mode; connect the EXTMODE to VSS. 【Remark4-3】The display ON/OFF signal is only for display. Data in the memory will be saved at the time of ON/OFF. When it’s ”H”, data in the memory will display, when it’s ”L”, white color will diaplay and data in the memory will be saved. 4-2)Recommended Circuit COM signal serial input External COM signal input EXTMODE=”L” EXTMODE=”H”

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 5. Absolute Maximum Rating Table5-1 ( GND=0V ) Item Symbol MIN. MAX. Unit Remark Analog VDDA -0.3 +5.8 V Power supply voltage Logic VDD -0.3 +5.8 V [Remark5-1] Input signal voltage(high) VDD V [Remark5-2] Input signal voltage(low) -0.3 V Strage Temperature Tstg -30 +80 ℃ [Remark5-3,4] Operation Temperature (at panel surface) Topr1 -20 +70 ℃ [Remark5-5] [Remark5-1] Applies to EXTMODE. [Remark5-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN. [Remark5-3] Do not exceed this temperature in any parts of module. [Remark5-4] Maximum wet bulb temperature is 57℃ or lower. No condensation is allowed. Cndensation will cause electeical leak and may cause the module to not meet this specification. [Remark5-5] Operating temperature is the temperature that guarantees only for the operation. For contrast, response time, and other display quality determination, use Ta=+25℃.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6. Electrical characteristics 6-1) TFT LCD panel drive Table6-1 Recommended operating Condition VSS(GND)=0V、Ta=+25℃ Item symbol MIN. TYP. MAX. Unit Remark Analog VDDA +4.8 +5.0 +5.5 V Power supply Logic VDD +4.8 +5.0 +5.5 V [Remark6-1] Hi VIH +2.70 +3.00 *VDD V Input signal voltage Lo VIL VSS VSS VSS+0.15 V [Remark6-2] *It can be operated below VDD voltage, however, operation around 3V is recommended. [Remark6-1] Applies to EXTMODE=”H” [Remark6-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-2) Power supply sequence ※Refer to timing chart and AC timing characteristics for detail ※1 ③ and ④ may be opposite (however, TCOM polarity inversion will not occur even with EXTCOMIN between DISP=”L”. Also, when DISP and EXTCOMIN are simultaneously started up, allow 30us or more before SCS starts up (It may be less than 60us). ※2 Setting value for pixel memory initialization SCS=Driving accordingly to clear pixel internal memory method (use all clear flag or write all screen white) S1=M2 (all clear flag) = “H” or write white SCLK: Normal Driving [Remark] Precaustions at ehte time of power on and power off. Remark 1)When power on , VDDand VDDA are same timem or VDD should be faster than the VDDA. Remark 2) When power off, VDD and VDDA are same time or VDDA shoud be faster than the VDD. ①② ③※1 ④※1 ⑤⑥⑦ VDD/VDDA(5V) GND GND DISP GND GND EXTCOMIN GND GND SCS GND ※2 ※2 GND Others GND ※2 ※2 GNDNormal operation Normal operation Normal operation Off sequenceNormal operation T2 T3 T4 T5 T6 T7 On Sequence [ON Sequence] (1) 5V rise time (depends on IC) (2) Pixel memory initialization T2: 1V or more Init ialize with M2 (all clear flag) or write all screen white (3) Release time for initialization of TCOM latch T3: 30us or more Time required to release COM related latch circui t initialization which is initializing using DISP signals (4) TCOM polarity initialization time T4: 30us or more Time required initializing TCOM polarity accordingly to EXTCOMIN input [Normal Operation] Duration of normal driving [Off Sequence] (5) Pixel memory initialization time T5: 1V or more (6) VA, VB, VCOM initialization time T6: 1V or more (7) 5V falling time (Depends on IC)

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-3) Input signal characteristics Table6-3-1 VDDA= +5.0V、VDD=+5.0V、GND=0V、Ta=25℃ Item Symbol MIN TYP MAX Unit Remark Frame frequency fSCS 1 - 60 Hz Clock frequency fSCLK 1 2 MHz Vertical Interval tV 16.66 - 1000 ms COM Frequency fCOM 0.5 - 30 Hz Table 6-3-2 VDDA= +5.0V、VDD=+5.0V、GND=0V、Ta=25 Item Symbol MIN TYP MAX Unit Remark SCS Rising time trSCS - - 50 ns SCS Falling Time tfSCS - - 50 ns 92 - - us SCS High duration twSCSH 12 - - us SCS Low duration twSCSL 1 - - us SCS set up time tsSCS 3 - - us SCS hold time thSCS 1 - - us SI frequency fSI - 0.5 1 MHz SI Rising time trSI - - 50 ns SI Folling time tfSI - - 50 ns SI set up time tsSI (120) - - ns SI hold time thSI (125) - - ns SCLK Rising time trSCLK - - 50 ns SCLK Folling time tfSCLK - - 50 ns SCLK High duration twSCLKH 200 450 - ns SCLK Low duration twSCLKL 200 450 - ns EXTCOMIN signal freequency fEXTCOMIN 1 60 Hz [Remark6-3] EXTCOMIN signal rising time trEXTCOMIN - - 50 ns EXTCOMIN signal folling time twEXTCOMIN - - 50 ns EXTCOMIN signalHigh duration thlEXTCOMIN 1 us DISP Rising time trDISP - - 50 ns DISP Folling time tfDISP - - 50 ns 【Remark 6-3】 EXTCOMIN frequency should be made lower than frame frequency.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 10% 90% 10% 90% 10% 90% 10% 90% 10% 90% 50% 10% 90% 50% 50% 10%10% 50% 50% 50% 50% twSCSH twSCSL tfSCSthSCStrSCS tsSCS trSI tsSI thSI tfSI trSCLK tfSCLK twSCLKH twSCLKL SCS SI SCLK 10% 90% 10% 90% trEXTCOMIN 50% 50% 50% twEXTCOMINH fEXTCOMIN tfEXTCOMIN 10% 90% 10% 90% trDISP tfDISP EXTCOMIN DISP SCS, SI, SCLK signal EXTCOMIN signal DISP signal ※SCS,SI,SCLK、DISP、EXTCOMIN: 3V input voltage

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-4) Power consumption (Average) Table6-4 Ta=25℃ Item MIN TYP MAX unit Remark Condition1 - 15 - uW [Remark6-4] Condition2 - 50 - uW [Remark6-4] * Measurement Condition 1 Display mode (no display data update), Display pattern: Vertical stripe display * Measurement Condition 2 Data update mode (with display data update: 1Hz) Common inversion with VDD=5V、VDDA=5V、fSCLK=1MHz、fSCS=1Hz, Display pattern: Vertical stripe display 【Remark 6-4 】 This is value in steady condition, not the falue of peak power at the time of COM operation. Some marging for power supply is recommended. We re commend capacitor for VDD and VDDA. (If VDD and VDDA are on separate systems, we recommend capacitor for each.)

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-5) Input Signal Timing Chart 6-5-1 Data update mode (1 line) Updates data of only one specified line. (M0=”H”、M2=”L”) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※For gate line address setting, refer to 6-6) Input Signal and Display. ※M1: Frame inversion flag is enaled when EXTMODE=”L”. ※When SCS becomes “L”, M0 and M2 are cleared. M0 M1 M2 DMY DMY DMY DMY DMY AG0 AG1 AG2 AG3 AG4 AG5 AG6 AG7 D1 D2 D3 D4 D141 D142 D143 D144 DUMMY DATA(don't care) tsSI thSI tsSCS Data writing period (144ck) Data transfer period (16ck) Mode selection period (3ck+5ckDMY) twSCLKHtwSCLKL twSCSH Gate line address period (8ck) thSCS twSCSL SCS SI SCLK ※ Data write period Data is being stored in 1st latch block of binary driver on panel. ※ Data transfer period Data written in 1st latch is being transferred (written) to pixel internal memory circuit.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-5-2 Data Update Mode (Multiple Lines) Updates arbitrary multiple lines data. (M0=”H”、M2=”L”) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ For gate line address setting, refer to 6-6) Input Signal and Display. ※ Input data continuously. ※ M1: Frame inversion flag is enabled when EXTMODE= ”L”. ※ When SCS becomes “L”, M0 and M2 are cleared. DUMMY DATA(don't care) DUMMY DATA(don't care) DUMMY DATA(don't care) DMY D143 D144D2D1 AG0 AG1 AG2M0 M2 DMY DMYM1 DMY DMY D2AG1D4 AG0D141 D144D142 D143 D1D1 D2 D3 AG7AG6AG3 AG7 AG6AG5AG4 D143 AG7AG6AG5AG0 AG1 AG2D144 tsSI thSI tsSCS GL1st line GL2nd line GL(n)th line Data transfer period (16ck) GL(n-1)th line thSCS twSCLKHtwSCLKL twSCSLtwSCSH twSCSH Data transfer period (8ck(Dummy)+8ck(Address)=16ck) SCS SI SCLK Data writing period (144ck) Mode selection period (3ck+5ckDMY) Gate line address period (8ck) Data writing period (144ck) Data transfer period (8ck(Dummy)+8ck(Address)=16ck) Data writing period (144ck) ※ Data write period Data is being stored in 1st latch block of binary driver on panel. ※ Data transfer period For example, during GL2nd line data transfer period, GL 2 nd line address is latched and GL1st line data is transferred from 1st latch to pixel internal memory circuit at the same time.

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-5-3 Display Mode Maintains memory internal data (maintains current display). (M0=”L”、M2=”L”) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ M1: Frame inversion flag is enabled when EXTMODE=”L” ※ When SCS becomes “L”, M0 and M2 are cleared. SCS SI DUMMY DATA(don't care) DUMMY DATA(don't care) SCLK M0 M1 M2M0 M1 M2 tsSI thSI tsSCS Mode selection period (3ck) twSCSH tV thSCS twSCSL Data transfer period (More than 13ck)

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-5-4 All Clear Mode Clears memory internal data and writes white. (M0=”L”、M2=”H”) M0: Mode flag. Set it “L”. M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Set it “H” DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ M1: Frame inversion flag is enabled when EXTMODE=”L”. ※ When SCS becomes “L”, M0 and M2 are cleared. SCS SI DUMMY DATA(don't care) DUMMY DATA(don't care) SCLK M1 M2M0 M1 M2 M0 tsSI thSI tsSCS twSCSH tV thSCS twSCSL Mode selection period (3ck) Data transfer period (More than 13ck)

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6-5-5 COM Inversion There are two types of inputs, COM signal serial input (EXTMODE=”L”) and external COM signal input (EXTMODE=”H”). EXTMODE=“L” M1:LC polarity inversion flag: If M1 is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output. ※1:LC inversion has been changed by M1 flag statement. ※2:The periods of plus polarity and minus polarity should be same length as much as possible. EXTMODE="H" ( COM inversion timing has two conditions ) SCS EXTCOMIN COM ※3:LC inversion polarity has been set by the rising edge of EXTCOMIN. ※4:The period of EXTCOMIN should be constant. fCOM ※4 ※4 fEXTCOMIN twEXTCOMINH ②: the EXTCOMIN input during low period of the SCS signal . SCS EXTCOMIN COM ※1:LC inversion polarity has been set by the falling edge of SCS signal. ※2:The period of EXTCOMIN should be constant. fCOM ※2 ※2 ※1 ※1 fEXTCOMIN twEXTCOMINH ①: the EXTCOMIN input during high period of the SCS signal . SCS SI COM M0 M1 M2 M0 M2 M1 M2 M0 M1 fCOM ※2 ※2 ※1 ※1 ※1

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE GL AG0 AG1 AG2 AG3 AG4 AG5 AG6 AG7 10000000 01000000 11000000 00100000 10100000 01100000 11100000 00010000 10000101 01000101 11000101 00100101 10100101 01100101 11100101 00010101 168 167 166 165 164 163 162 161 6-6) Input Signal and Display, Gate address(Line) Setting Data position in display〔H,V〕 P1,L1 P1,L2 P1,L3 P2,L1 P2,L2 P3,L1 UP Display side up P1,L1 P1,L2 P1,L3 P1,L168 P2,L1 P144,L168 P144,L1 P2,L2 P3,L1 Display side up Gate line address setting

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 7. Optical characteristics Table 7-1 Ta=25 Item Symbol MIN. TYP. MAX. unit Remark H θ21,θ22 (40) (55) °(degree) θ11 (40) (60) °(degree) Viewing angle CR≧2 V θ12 (40) (60) °(degree) [Remark7-1] Contrast ratio CR. (14) [Remark7-2 、3] Reflecivity ratio R (17) % [Remark7-3] Transmissivity ratio T (0.3) % Rise τr 10 ms Response time Fall τd 20 ms [Remark 7-3,4] x (0.307) [Remark7-3] Panel Chromaticity White y (0.330) [Remark7-3] Optical characteristics measurement equipment. Figure 7-2 is for contrast ratio, reflectivity ratio, and panel chromaticity measurement, and figure 7-3 is for response time measurement. Both are to be conducted in a dark or room equipment to a dark room Fig7-2 Contrast ratio, Reflection ratio, Panel chromaticity of white Fig7-3 response time LCD panel Normal line Light receiver Light source -30° Display center Measurement equipment (LCD-5200) Measurement equipment (CM-2002) Normal line Light receiver Light source LCD panel Display center Integrating sphere

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE [Remark7-1] Defintion of Viewing Angle [Remark7-2] Defintion of Contrast Retio Contrast ratio(CR) = [Remark7-4] Respons time (Change in reflection ratio) It’s difined by the time change of optical receiver output when signal is input to display white or black Reflection intensity in white display Reflection intensity in black display Δθ21 Δθ22 Δθ12Δθ11 Normal Line 6 o’clock direction White Black White Optical receiver output (Incremental) Time

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 8. Module outline 8-1) Outline dimension of the 1.26” (144 x 168) panel f i g . 8 - 1 f i g . 8 - 2 fig. 8-3

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 9. External capacitors Fig. 9-1 External capacitor recommendation capacity value < Recommended capacity value> C1:DISP- VSS: rank B 0.1uF Ceramic capacitor C2:VDDA- VSS: rank B 1uF Ceramic capacitor C3:VDD- VSS: rank B 1uF Ceramic capacitor ※Above circuit and parts are only recommendation. For actual use, please evaluate their conformity with your system and design. (Capacitor pressure resistance can be larger than resistance indicated above.)

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 10. External Power Supply Circuit An external power supply circuit is necessary to drive the Pixel Memory LCD with the 3V battery. Table 1-1 shows power supply IC of the recommendation. Table 1-1 Maker Model Number Note SII S-8821 Charge pump type National Semiconductor LM2750 Charge pump type Refer to specifications of each power supply IC for a detailed specification. Set the constant value after it evaluating it sufficiently by an actual application when you use it. Electrical specification Table 2-1 Vin [V] Vout Model Number min max min typ max Iout [A] Refer to specifications of each power supply IC for a detailed specification. Set the constant value after it evaluating it sufficiently by an actual application when you use it. Reference circuit The reference circuit is shown below. S-8821 LM2750

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 11. Zebra connector Contact Resistance :lower than 100Ω 【Recommended zebra connector】 Shin-Etsu Polymer: SX type Recommended compression ratio :15±8% The zebra connector placement position 1.SX Specifications(A figure of reference) F i g 1 1 - 1

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 12. Packaging 12-1) Serial number (Ink-jet print) Will be indicated on serial number label as indicated in Figure 12-1 outline dimension figure. Print structure ABC D Serial number specifications A:a single figure of the year B:month(1,2....9,X,Y,Z) C:day D:serial number Fig. 12-1 Serial number print position 12-2) Forwarding form 1) Piling number of cartons : TBD Package quality in a carton : TBDpcs 2) Storage condition Temperature: 0 ~40° Humidity: 60%RH or lower (at 40°) There should be no condensation at low temperature and high humidity. Atmosphere: No harmful gas, such as acid or alkali, which causes severe corrosion on electronic parts and wiring, are to be detected. Period: About 3 months Opening the package: In order to prevent electrostatic damage to TFT modules, room humidity should be made over 50%RH and take effective measure such as use of earth when opening the package. Model number Print location is TBD

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 12-3) Packaging Packageing size :578mmx382mmx153mm Fig. 12-2 Packaging Form

SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 13. Reliability Test Conditions 13-1) Reliability test items Table13-1 Test Item Test condition Remark

1 High temperature storage test Ta=80degrees Celsius 240h

2 Low temperature storage test Ta=-30degrees Celsius 240h

High temperature and high humidity operating test Tp=40degrees Celsius/95%RH 240h

4 High temperature operating test Tp=70degrees Celsius 240h

5 Low temperature operating test Tp=-20degrees Celsius 240h

(Non operating test) Ta=-30degrees Celsius (1h) ~+80 degrees Celsius (1h) / 5 cycle

7 Electro static discharge test ±200V、200pF(0Ω) each terminai: 1 time

[Remark] Ta = Ambient temperature, Tp = Panel temperature (Evaluation method) In the standard condition, there shall be no practical problems that may affect the display function. 13-2) Panel surface stress spesification Panel surface stress spesification has been defined as a parameter “Force of stress [N]” without no picture failer. Load testing: Minimum 120[N] Test condition ) Test stracture :LCD panel with polarizer Press point :Center of LCD panel Press Jig :φ10mm column Press speed :1mm/minute Support :fixed on stage Press time :5 seconds after achivement of the press strength,then reless it.