OPERATION & MAINTENANCE INSTRUCTIONS GC11/18 - ISS 2 ORIGINAL INSTRUCTIONS SUBMERSIBLE WATER PUMPS MODEL NO: CSE2,CSD3,CSV1A,CSV2A PART NO: 7230560, 7230610, 7230580, 7230600
Thank you for purchasing this CLARKE Submersible Water Pump. CSE pumps are designed for pumping clean water only and will pump down to a water level of 20mm. This pump is designed for pumping clean water or water containing solids in suspension and is ideally suited for draining ponds, pools, sumps etc. It is not designed for pumping slurry, sludge, mud or heavily polluted water, or any water containing chemicals or other acidic contaminants including salt water. Pumps fitted with float switches are suitable for permanent or semi-permanent installations where it is necessary to maintain water at a particular level. As the water level rises, the float switch will rise and start the pump. As the water level falls, so will the float switch until it stops the pump. Float switches are factory set to provide the correct on/off switching mode, however, you can adjust the level at which the pump cuts out by sliding the float switch cable in its clip attached to the handle, to either shorten or lengthen as required. The shorter the cable, the earlier it will cut out and therefore, the deeper the water will remain at this point. PUMP SPECIFICATION CSE2 CSD3 CSV1A CSV2A Dimensions excluding the elbow 140 x 302mm 149 x 400mm 143 x 300mm 143 x 35mm Weight 4.3kg 8.0 kg 4.6 kg 5.6 kg Cable Size 10 x 0.75 x mm2) 15 x 1.0 (m x mm2) 10 x 0.75 (m x mm2) 10 x 0.75 (m x mm2) Max. Capacity 253 L/min 95 L/min 118 L/min 236 L/min Head Max 10 m 45 m 5 m 9 m Motor Output 750 W 900 W 330 W 650 W Outlet Diameter 1¼”/ 32mm 1”/ 25mm 1¼”/ 32mm 1¼”/ 32mm S
- These pumps are designed to pump WATER ONLY. Never use for pumping flammable liquids or chemicals. 2. Never run the pump dry. 3. An approved Residual Current Device (RCD) which has a tripping current of less than 30mA must be used when pumping from ponds or swimming pools. 4. Never carry the pump by the mains lead or float switch. 5. Never pull the mains lead to disconne ct the pump from the mains socket. 6. Your submersible pump may only be used for pumping water from a swimming pool when there is no person or animal in the pool. 7. Always disconnect the pump from the electrical supply before placing it into, or removing it from the water and before any cleaning or maintenance. 8. Always use the moulded handle (or lifting eye), with a rope or cable attached when lifting the pump. NEVER lift the pump by the mains cable or, where fitted, the float switch cable. 9. DO NOT run the pump with the body exposed for longer than 10 minutes. 10. DO NOT install the pump on sand or ground which is likely to shift. 11. Do not use the pump if the water is liable to freeze, as this can cause damage to the pump. Remove the pump from the water and store it in a frost free location. 12. If the pump is to be used where there may be silt or mud (for example, garden ponds), keep the pump clear of any sediment by standing it on a platform or brick. 13. Do not allow children to touch the pump, cables or connections. 14. Disconnect the pump from the mains supply when not in use. 15. Have the pump repaired by a qualified person. 16. Keep the mains cable away from heat, oil and sharp edges. 17. Always check the plug, mains cable and float switch cable for damage before use. Do not use the pump if damaged. Refer to qualified service personnel for repair. 18. If you have to use an extension lead with this product, it must be designed for outdoor use and incorporate a cable suitable for use with Class I appliances.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch. If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions shown below. The old plug must be discarded safely, as insertion into a power socket could cause an electrical hazard. If the colours of the wires in the power cable do not agree with the markings on the plug. The BLUE wire must be connected to the terminal which is marked N or coloured black. The BROWN wire must be connected to the terminal which is marked L or coloured red. The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green. AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING CURRENT OF LESS THAN 30 mA MUST BE USED. If you are not sure, consult a qualified electrician. DO NOT try to do any repairs. WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOR OUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY. WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH Plug must be BS1363/A approved. Always fit Ensure that the outer sheath of Neutral (Blue) Live (Brown) Earth (Green and a 13 Amp the cable is firmly held by the clamp fuse. Yellow)
Fit the elbow adaptor to the pump outlet as shown in the diagram o pposite. 2. Screw the multi-hose adaptor onto the elbow The multi hose adaptor is ca pable of accepting 1”, ¾”and ½” hoses. Simply cut the multi hose connector to the required size and attach a suitable hose using with a worm drive clip. For maximum efficiency, we strongly recommend that you connect a 1¼” diameter hose to the multi hose adapter. Alternatively, you may remove the multi adapter altogether, and screw on a 1¼” BSP hose adapter. The pump is completely submersible and should be placed in a vertical position on a solid flat surface, placing the pump on a couple of house bricks if required. SUITABLE HOSES AND SPARE/REPLACEMENT MULTI HOSE ADAPTERS ARE AVAILABLE FROM YOUR CLARKE DEALER. WARNING: DISCONNECT THE PUMP FROM THE MAINS POWER SUPPLY BEFORE CONNECTING THE MULTI HOSE ADAPTOR.
- Place the pump on a flat surface in the area that you want to drain. If there is sediment in the operating area the pump should be placed on house bricks or similar. Ensure the pump is positioned with adequate space so that the movement of the float switch is not restricted - recommended minimum area of 40 x 40cm. ALWAYS raise and lower the pump using a rope attached to the lifting handle. Take all necessary precautions as described on page 3 before plugging in and switching ON. 2. Connect the mains plug to a high sens itivity residual current device (RCD) which has a tripping current of less then 30mA. 3. Switch the mains power supply on. The pump incorporates a float sw itch which automatically switches the pump ON when the water is above a pre-determined level. The pump will begin to drain water. As the water level falls, so will the fl oat switch until it stops the pump. 4. Disconnect the pump from the mains power supply when finished. These pumps are fitted with automatic thermal overload protection. If the pump overheats due to an obstruction in the pump or pumping warm water for example, it will shut off automatically. Switch the pump OFF and disconnect from the mains supply. Check for blockages and allow the motor to cool (at least 5 minutes) before attempting to re-start. WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE. DO NOT USE THE PUMP IF IT IS DAMAGED IN ANY WAY. WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES. WARNING: NEVER CARRY THE PUMP USING THE MAINS POWER CABLE. DAMAGE TO ELECTRICAL CABLES CAN BE HAZARDOUS. ALWAYS USE THE HANDLE WHEN MOVING THE PUMP. CAUTION: DO NOT ALLOW THE PUMP TO RUN DRY
These pumps should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. Do not use the pump if there is any damage to the mains supply cable or to the float switch or its cable. Do not attempt to repair the pump yourself as you may damage the waterproof seal and invalidate your guarantee. Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400. If the troubleshooting on page 8 does not solve your problem please contact the Clarke service department. CLEANING 1. Check the pump installation regularly to ensure the base inlet is clear of leaves or other debris. These pumps have screwless fittings at their base, allowing the removal of the plastic cover by prising the two release clips apart in the direction of the arrows. This allows better a ccess to the cavity at the bottom, should the pump become badly clogged. Flush the cavity and the impeller housing with clean water. To replace the cover, ensure the release clips line up with the holes on the base of the pump and press the cover home. NOTE: Do not attempt to strip the pump further as this will invalidate the guarantee. WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT IS UNPLUGGED FROM THE MAINS SUPPLY.
- Check to ensure power is switched on. 2. Check fuse (consult an electrician if in doubt). 3. If extension lead is fitted, check connections (consult an electrician if in doubt). 4. Internal thermal cut-out has not re-set. Leave for 5 min utes and try again. 5. The impeller may be jammed. Disconnect from the mains supply, remove the bottom strainer and remove any objects that may be obstructing the impeller. Replace the strainer and try again. 6. If the pump still fails to star t consult your CLARKE dealer for advice. 7. Floatswitch may be jammed against side wall or pre vented from moving. 8. Water level too low - float swit ch in OFF position - lift float to check switch. PUMP WILL ST ART BUT NOT PUMP 1. Check to ensure strainer is not blocked. 2. Discharge tube clogged or obstructed. 3. The head may be too great, i.e. you are trying to lift the w ater too great a distance for the pump to cope with. (See specifications on page 2). 4. Air bubble in the pump, produced during the plunge. Plun ge the pump again at an angle and shake it whilst lowering to remove any air trapped in the system. 5. Impeller may be damaged - Consult you r CLARKE dealer. PUMP WILL NOT STOP 1. Float switch may be prevented from moving to the fully down position. 2. Float switch may be faulty. Consult your CLARKE dealer for advice. PUMP STOPS RUNNING 1. Thermal overload has operated. If this condition persists, investigate the cause. Are you attempting to pump liquid which is too heavy for the pump (mud, slurry etc.) 2. Pump has run dry or float switch has cut in. 3. A foreign object ha s jammed the impeller.
- CSV1A/2A
NO DESCRIPTION CSV1/A CSV2/A
1 Floatswitch LDP1380002 LDP1380002
2 Cap LDS3600170 LDS3600170
3 Cable 10m LDP1320016 LDP1320016
4 Grommet CSV2 ONLY
5 Grommet LDP1230003 LDP1230003
6 Flux Capacitor LDP1360030 LDP1360030
7 Lock LDS3500011 LDS3500011
8 Anti-tear Ring-piece LDS3500336 LDS3500336
9 Cable Fastener LDS3500335 LDS3500335
10 Screw LDP1100008 LDP1100008
11 Earth Screw LDP1100003 LDP1100003
12 Spring Washer LDP1120003 LDP1120003
13 Washer LDP1120051 LDP1120051
14 Insulation Disc LDS3500106 LDS3500106
15 Upper Flange LDS3120005 LDS3120005
16 Wave Washer LDP1120002 LDP1120002
17 Ceramic Shaft/Bearings LDS3101001 LDS3101002
18 Bearing LDP1180001 LDP1180001
19 Washer LDP1120007 LDP1120007
20 Lip Seal LDP1210001 LDP1210001
21 Stator LDS3410004 LDS3410017
22 Joint O-ring LDP1200007 LDP1200007
23 Pump Housing LDS3500206 LDS3500207
24 Joint O-ring LDP1200009 LDP1200009
25 Elbow with O-ring LDS3600111 LDS3600111
26 Washer LDP1120006 LDP1120006
27 Nut LDP1110005 LDP1110005
28 Impellor LDS3500013 LDS3500014
29 Joint O-ring LDP1200008 LDP1200008
30 Pedestal LDS3500018 LDS3500018
31 Joint O-ring LDP1200033 LDP1200033
32 Screw LDP1100090 LDP1100090
33 Screw LDP1100014 LDP1100014
34 Washer LDP1120017 LDP1120017
35 Sphere LDP1180003 LDP1180003
36 Twin Lip Seal LDP1210004 LDP1210004
37 Joint O-ring LDP1200002 LDP1200002
38 3-step Fitting with O-ring LDS3600162 LDS3600162 - CSV1A/CSV2A
- CSE2
NO DESCRIPTION PART NO NO DESCRIPTION PART NO
1 Float-switch LDP1380002 21 Stator LDS3410017
2 Cap LDS3600170 22 Joint O-ring LDP1200007
3 Cable 10m LDP1320016 23 Pump housing LDS3600075
4 Grommet LDP1230002 24 Joint O-ring LDP1200009
5 Grommet LDP1230003 25 Elbow with O-ring LDS3600111
6 Capacitor LDP1360030 26 Washer LDP1120006
7 Lock LDS3500011 27 Nut LDP1110005
8 Anti-tear ring LDS3500336 28 Impeller LDS3500559
9 Cable fastener LDS3500335 29 Joint O-ring LDP1200008
10 Screw LDP1100008 30 Filter LDS3500017
11 Earth screw LDP1100003 31 Filter Base LDS3500107
12 Spring-washer LDP1120003 32 Joint O-ring LDP1200033
13 Washer LDP1120051 33 Screw LDP1100090
14 Insulation disc LDS3500106 34 Screw LDP1100014
15 Upper flange LDS3120005 35 Washer LDP1120017
16 Wave washer LDP1120002 36 Ball LDP1180003
17 Ceramic shaft with
LDS3101002 37 Twin Lip Seal LDP1210004
18 Bearing LDP1180001 38 Joint Ring LDP1200002
19 Washer LDP1120007 39 Step Fitting /O-ring LDS3600162
20 Lip seal LDP1210001 40 V-ring Joint LDP1210002
- CSE2 ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste but according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
- CSD3
NO DESCRIPTION PART NO NO DESCRIPTION PART NO
1 Pipe fitting/O-ring LDS3600107 23 Stator LDS3410014
2 Joint O-ring LDP1200002 24 Twin lip seal LDP1210004
3 Non-return valve LDS3600099 25 Joint O-ring LDP1200007
4 Spacer LDP1230003 26 Joint O-ring LDP1200012
5 Power cable LDP1330011 27 Pump housing LDS3500737
6 Float-switch LDP1380002 28 Joint O-ring LDP1200020
7 Cap LDS3600186 29 Joint O-ring LDP1200015
8 Capacitor LDP1360003 30 Screw LDP1100012
9 Grommet LDP1230003 31 Diffuser flange LDS3600156
10 Anti-tear ring LDS3500336 32 Washer LDP1120012
11 Cable fastener LDS3500335 33 Hexagonal shaft LDS3100019
12 Screw LDP1100008 34 V-ring LDP1210005
13 Earth screw LDP1100003 35 Impeller LDS3250028
14 Spring washer LDP1120003 36 Joint O-ring LDP1200014
15 Washer LDP1120051 37 Diffuser LDS3250006
16 Insulation disc LDS3500106 38 Diffuser cap LDS3500611
17 Upper flange LDS3120005 39 Washer LDP1120014
18 Wave washer LDP1120002 40 Nut LDP1110009
19 Bearing LDP1180001 41 Filter ring LDS3220006
20 Shaft with bearings LDS3101004 42 Filter base LDS3500743
21 Washer LDP1120007 43 Screw LDP1100017
22 Lip seal LDP1210001 44 Cap LDP1230006
- CSD3 GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.