- High Operating Ambient Temp: -30℃~+60℃
- Surge protection: L-N 2KV, L-FG/N-FG 4KV (L-N 4KV L-FG/N-FG 6KV For LCVH-150U120)
- Safety: UL 60950 / PSE / CB
- EMI: FCC Part 15 Class B / CE
- IP 67 Compliant
- Warranty: 5 years (refer to warranty policy)
- RoHS Compliant 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Units Vac Hz A A mA Units V s Units Io Units %RH %RH g Over Current Protection 160% Auto recovery ±5% Input Specifications EFFICIENCY (Typ.)
- AC Input 100~277VAC
- Built-in Active PFC Function
- Protection: SCP / OVP / OTP / OCP Power Factor (Typ.) ±5% DC OUTPUT VOLTAGE (V) Constant Voltage Mode OUTPUT CURRENT (A) OUTPUT VOLTAGE TOLERANCE LCVH-150U300 ±5% Non-condensing ±5% Power Supply 150-LCVH Series PRODUCT SPECIFICATION FEATURES: LCVH-150U240 151.2 LCVH-150U480 153.6 3.2 4.2 6.3 MODEL DC OUTPUT POWER (W) 150 5 ±5%30 LCVH-150U120 150 12 12.5 ±5% LCVH-150U420 151.2 42 3.6 Min. Max. Conditions/Description Input Voltage Range 90 305 Input Frequency Range 47 63 Input Current 100VAC in Inrush Current 65 230VAC in,25℃ Cold start Leakage Current 0.45 230VAC in Power Factor (PF) 0.9 100-277VAC,100% loadTotal Harmonics Distortion (THD) 15 Output Specifications Min. Max. Conditions/Description Line Regulation ±3 Typ. Load Regulation ±3 Output Voltage Regulation ±5 Ripple and Noise (pk-pk) 0.5 20MHz Bandwidth. See note (3) Ripple Current N/A Turn-on Delay Time 2 *Measured at 100-277VAC and at full load Protection Functions Min. Max. Conditions/Description Short Circuit Protection Auto recovery Over Voltage Protection Latching,See individual models OVP levels Over Temp Protection (Tc) Latching,re-power on to recover Environmental Conditions Min. Max. Conditions/Description 105 Operating Temperature (Ta) -30 60 Non-condensing Operating Case Temperature (Tc) 95 Case temperature measured at the case hot spot. Operating Humidity 10 Storage Temperature -40 80 Non-condensing Storage Humidity 10 95 Non-condensing Life Time Measured at 277Vac, 45,000 hours at Tc 75°C . Dimensions(L*W*H) 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch Weight 1000 Typ. LCVH-150U360 151.2 36 Typ. Typ. 1.75 Linkcom Manufacturing Co., Ltd.
(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Only for LCVH-150U120 model. Constant Voltage Mode Voltage Fluctuations & Flicker EMS Standards Electrostatic Discharge (ESD) RF Electromagnetic Field Susceptibility Electrical Fast Transient Surge Immunity Safety
8 KV air discharge, 4 KV contact discharge
*REFERENCE: www.linkcom.com.tw (4) Specified for free-air convection cooling. (5) Operating in minimum load is not proper requiremant CB IEC 61000-4-4 IEC 61000-4-5 L-N 2KV, L-FG/N-FG 4KV (L-N 4KV L-FG/N-FG 6KV For LCVH-150U120) Conducted RF Disturbances Power Frequency Magnetic Field UL 60950 IEC 61347-2-13 , IEC 61347-1 IEC 61000-4-11Voltage Dips DERATING CURVE IEC 61000-4-6 IEC 61000-4-8 UL PSE (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. EN 61000-3-3 EMC Compliance and Safety EMC Compliance Harmonic Current Emissions IEC 61000-4-2 IEC 61000-4-3 Conducted and Radiated Emmission EN 55015 (CISPR15) , FCC Part 15 Class B EN 61000-3-2 Class C PSE Notes Linkcom Manufacturing Co., Ltd.
*Other models DIMENSIONS For LCVH-150U120 model. *REFERENCE: www.linkcom.com.tw Constant Voltage Mode Tc Max. Linkcom Manufacturing Co., Ltd.
*Other models Constant Voltage Mode *REFERENCE: www.linkcom.com.tw Linkcom Manufacturing Co., Ltd.
Output Voltage vs. Load (LCVH-150U240) Efficiency vs. Load (LCVH-150U240) Power Factor vs. Load (LCVH-150U240) Constant Voltage Mode 75% 80% 85% 90% 95% 30% 40% 50% 60% 70% 80% 90% 100% 110% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 0.70 0.75 0.80 0.85 0.90 0.95 1.00 30% 40% 50% 60% 70% 80% 90% 100% 110% Power Factor Load(%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 30% 40% 50% 60% 70% 80% 90% 100% 110% Output Voltage (V) Load (%) Output Voltage vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.