DBFN LINKCOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

  • AC Input 100~277VAC
  • Built-in Active PFC Function
  • Protection: SCP / OVP / OTP
  • 24V Auxiliary Output
  • 0-10V Dimming Control
  • Dimming 1% ~ 100%
  • Flicker Free
  • High Operating Ambient Temp.: -20℃~+50℃
  • Surge protection: L-N 2KV , L-FG/N-FG 4KV
  • Safety: UL 8750 / PSE
  • EMI: FCC Part 15 Class B / CE
  • Comply with Indoor
  • Warranty: 7 years (refer to warranty policy)
  • RoHS Compliant 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Units Vac Hz A A mA Units V s V A Units Units %RH %RH g 24 ± 5% Tolerance (Available for customization) Auxiliary Output Source Current 0 0.1 DBFN-050U222 52.8 12-24 2.2 ±5% Storage Temperature Input Specifications -20 Non-condensing Storage Humidity 10 Life Time Measured at 277Vac, 60,000 hours at Ta 50°C for DBFN-050U222. Dimensions(L*W*H) 370 * 31.2 * 27.2 mm 14.5 * 1.23 * 1.07 inch Max. Conditions/Description Typ. Weight Auxiliary Output Voltage Power Factor (Typ.) Typ. Output Specifications Min. Typ. 24-48 24-56 380

95 Non-condensing

Operating Temperature (Ta) -20 50 Non-condensing Operating Case Temperature (Tc) 75 Case temperature measured at the case hot spot Operating Humidity 10 Over Temp Protection (Tc) will restart automatically after the fault condition is removed Environmental Conditions Min. Max. Conditions/Description Short Circuit Protection will restart automatically after the fault condition is removed Over Voltage Protection will restart automatically after the fault condition is removed Turn-on Delay Time 1 *Measured at 100-277VAC and at full load Protection Functions Min. Max. Conditions/Description Ripple and Noise (pk-pk) 0.5 20MHz Bandwidth. See note (3) Ripple Current <30% of rated output current *Measured at electronic load LED mode and nominal input voltage with DC10V dimming. Load Regulation Output Current Regulation 10 10 Line Regulation Typ. Power Factor (PF) 0.9 100-277VAC,100% loadTotal Harmonics Distortion (THD) 15 Inrush Current 65 230VAC in,25℃ Cold start Leakage Current 0.75 277VAC in Input Frequency Range 47 63 Input Current ±7% 0.8 100VAC in Max. Conditions/DescriptionMin. 15-30 DBFN-050U901 50.4 0.9 ±10% DBFN-050U182 Input Voltage Range 90 305 1.8 ±10% 1.4 ±7% DBFN-040U701 39.2 0.7 ±7%28-56 DBFN-040U142 42 DBFN-040U152 36 1.5 DBFN-040U901 43.2 0.9 15-30 DC OUTPUT POWER (W) OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% DBFN-040U182 43.2 1.8 ±7%12-24 EFFICIENCY (Typ.) DBFN-040U102 36 18-36 1 DC OUTPUT VOLTAGE (V) 12-24 MODEL Non-condensing ±10% Power Supply DBFN Series PRODUCT SPECIFICATION FEATURES: 0-10V Dimmable Linkcom Manufacturing Co., Ltd.

(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information Harmonic Current Emissions FCC Part 15 Class BConducted and Radiated Emmission *REFERENCE: www.linkcom.com.tw Conducted RF Disturbances Voltage Fluctuations & Flicker EMS Standards EMC Compliance and Safety EMC Compliance (5) Minimum load is NOT required for proper operation . UL 8750 (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4) Specified for free-air convection cooling. UL PSE Comply with PSE Notes Electrostatic Discharge (ESD) RF Electromagnetic Field Susceptibility Power Frequency Magnetic Field Electrical Fast Transient Surge Immunity Voltage Dips Safety L-N 2KV , L-FG/N-FG 4KV

8 KV air discharge, 4 KV contact discharge

0~10V Dimmable Linkcom Manufacturing Co., Ltd.

*REFERENCE: www.linkcom.com.tw DERATING CURVE 0~10V Dimmable 0~10V Dimmable Line LED+ Return Dim- Dim+ Aux 24 V+ LED- Neutral DBFN-050U222 as Tc Max. Reference Tc Max. Linkcom Manufacturing Co., Ltd.

  1. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent. 3. When dimming wires +Purple/-Gray are left open, the output current will be at 100%. 1mA─ Notes: Absolute maximum voltageon on the Dim+ 0V 1. Purple and Gray wires on the output side are used for 0-10V dimming. Source current on the Dim+ 0mA 10V─ Parameters Minimum Typical Maximum 0~10V Dimmable Linkcom Manufacturing Co., Ltd.

Output Current vs. Load (DBFN-050U222) Efficiency vs. Load (DBFN-050U222) THD vs. Load (DBFN-050U222) 0~10V Dimmable 70% 75% 80% 85% 90% 40% 50% 60% 70% 80% 90% 100% 110% Efficiency (%) Load (%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 1.600 1.800 2.000 2.200 2.400 40% 50% 60% 70% 80% 90% 100% 110% Output Current (A) Load (%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 10% 15% 20% 25% 30% 40% 50% 60% 70% 80% 90% 100% 110% THD (%) Load (%) THD vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.

PF vs. Load (DBFN-050U222) 0~10V Dimmable 0.80 0.85 0.90 0.95 1.00 40% 50% 60% 70% 80% 90% 100% 110% Power Factor Load (%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.