200-LCVH LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
- AC Input 100~277VAC
- Built-in Active PFC Function
- Protection: SCP / OVP / OTP
- Flicker Free
- High Operating Ambient Temp.: -30℃~+60℃
- Surge protection: L-N 4KV, L-FG/N-FG 6KV
- Safety: UL 8750 / PSE
- EMI: FCC Part 15 Class B / CE
- IP 67 Compliant
- Warranty: 5 years (refer to warranty policy)
- RoHS Compliant 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Units Vac Hz A A mA Units V s Units Io Units %RH %RH g Life Time Measured at 277Vac, 57,000 hours at Tc 75°C . Dimensions(L*W*H) 246.4 * 74 * 43.55 mm 9.7 * 2.91 * 1.71 inch Weight 1400 Storage Temperature -40 80 Non-condensing Storage Humidity 10 95 Non-condensing Operating Humidity 10 90 Non-condensing Operating Case Temperature (Tc) 90 Case temperature measured at the case hot spot Min. Typ. Max. Conditions/Description Operating Temperature (Ta) -30 60 Non-condensing Over Temp Protection (Tc) 105 Auto recovery Environmental Conditions Short Circuit Protection Auto recovery Over Voltage Protection Auto recovery Protection Functions Min. Typ. Max. Conditions/Description Ripple Current N/A Turn-on Delay Time 3 *Measured at 100-277VAC and at full load Output Voltage Regulation ±5 Ripple and Noise (pk-pk) 0.5 20MHz Bandwidth. See note (3) Line Regulation ±3 Load Regulation ±3 Total Harmonics Distortion (THD) 20 Output Specifications Min. Typ. Max. Conditions/Description Leakage Current 0.7 277VAC in Power Factor (PF) 0.9 100-277VAC,100% load Input Current 2.25 100VAC in Inrush Current 70 230VAC in,25℃ Cold start Input Voltage Range 90 305 Input Frequency Range 47 63 Input Specifications Min. Typ. Max. Conditions/Description LCVH-200U420 201.6 42 4.8 ±5% LCVH-200U480 201.6 48 4.2 ±5% LCVH-200U240 201.6 24 8.4 ±5% LCVH-200U360 201.6 36 5.6 ±5% Power Factor (Typ.) LCVH-200U120 192 12 16 ±5% Power Supply 200-LCVH Series Constant Voltage Mode PRODUCT SPECIFICATION MODEL DC OUTPUT POWER (W) Over Current Protection 160% Auto recovery FEATURES: DC OUTPUT VOLTAGE (V) OUTPUT CURRENT (A) OUTPUT VOLTAGE TOLERANCE EFFICIENCY (Typ.) Linkcom Manufacturing Co., Ltd.
(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Operating in minimum load is not proper requiremant *REFERENCE: www.linkcom.com.tw Safety UL Comply with UL 8750 PSE PSE Notes Power Frequency Magnetic Field Comply with IEC 61000-4-8 Voltage Dips Comply with IEC 61000-4-11 Surge Immunity Comply with IEC 61000-4-5 L-N 4KV, L-FG/N-FG 6KV Conducted RF Disturbances Comply with IEC 61000-4-6 EMS Standards Electrostatic Discharge (ESD) Comply with IEC 61000-4-2 8 KV air discharge, 4 KV contact discharge RF Electromagnetic Field Susceptibility Comply with IEC 61000-4-3 Electrical Fast Transient Comply with IEC 61000-4-4 EMC Compliance and Safety EMC Compliance Constant Voltage Mode Conducted and Radiated Emmission Harmonic Current Emissions Comply with EN 61000-3-2 Class C Voltage Fluctuations & Flicker Comply with EN 61000-3-3 Comply with EN 55015 (CISPR15) , Comply with FCC Part 15 Class B Linkcom Manufacturing Co., Ltd.
*REFERENCE: www.linkcom.com.tw DERATING CURVE Tc Max. LCVH-200U240 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
Power Factor vs. Load (LCVH-200U120) Output Voltage vs. Load (LCVH-200U120) Constant Voltage Mode Efficiency vs. Load (LCVH-200U120) 75% 80% 85% 90% 95% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Efficiency (%) Load (%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Output Voltage (V) Load (%) Output Voltage vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 0.60 0.70 0.80 0.90 1.00 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Power Factor Load (%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.
THD vs. Load (LCVH-200U120) Constant Voltage ModeConstant Voltage Mode 10% 20% 30% 40% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% THD (%) Load (%) THD vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.