LCVE-060X125 LINKCOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

LinkCom Manufacturing Co., Ltd *,# =SEE NOTES BELOW MODEL SPECIFICATION (6)Load regulation measured from 20% to Full load. (7)Line regulation measured from 100VAC to 277VAC. (8)Preset accuracy measured at normal load, 120VAC input. ※Reference ◆ ROHS Compliant ◆ Satety: Meet UL / Meet TUV ◆ EMC: Meet CE / FCC ◆ Comply with Indoor/Outdoor Waterproof (IP 67) ◆ Dimension (L*W*H): 170 * 53 * 32 mm ◆ Dimension (L*W*H): 6.69 * 2.09 * 1.26 inch ◆ AC Input 90~305Vac ◆ Protection: SCP / OVP / OTP / OCP ◆ High Operating ambient Temp: -20 ℃ ~ +60 ℃ (Refer to output derating curve) ◆ Power Factor:>0.98@115Vac;>0.92@230Vac;@full load max. I/P-O/P :3.75KVAC, O/P-Grnd :0.5KVAC, I/P-Grnd :1.88KVAC I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25 ℃ / 70% RH 170 * 53 * 32 mm 【6.69 * 2.09 * 1.26 inch 】 Meet UL879 & Meet UL60950-1 / Meet TUV EN61347-2-13 Meet CE EN55015 / FCC Part15 DIMENSIONS (L*W*H) (9)100% Production Tested. (5)Minimum load is NOT required for proper operation . NOTES: (1)All parameters not specially mentioned are measured 230VAC input. (2)All specifications Typical @25 ℃, unless otherwise noted, at normal line and load. (3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4)Specified for free-air convection cooling. ISOLATION RESISTANCE OPERATING TEMP.*(4) HOLD UP TIME OVER TEMP. PROTECTION SAFETY EMI WITHSTAND VOLTAGE OVER CURRENT PROTECTION LEAKAGE CURRENT OVER V, PROTECTION SHORT CIRCUIT PROTECTION 1A/115VAC COLD START 50A @ 230VAC AC CURRENT INRUSH CURRENT (typ) 10 to +90%, non-cond. *(9) <0.7mA/230VAC Module : LCVE-060 /square7125

FEATURES

Range:47-63Hz, Normal :50-60Hz PF>0.98 @115VAC, PF>0.92@230VAC at full load and rated output voltage OUTPUT CURRENT(A) *(5) O/P NOISE (P-P, mV) *(3) LOAD REGULATION (%) *(6) PRESET ACCURACY (%) *(8) > 25ms at full load 115VAC/230VAC ACTIVE POWER FACTOR SETUP,RISE TIME(typ.) INPUT VOLTAGE RANGE INPUT FREQUENCY 90-305VAC, 127-431VDC, Normal :100-277VAC 85% 60 W 200 SIZE DC OUTPUT VOLTAGE (V) LINE REGULATION (%) *(7) 1300ms,500ms at full load 115VAC/230VAC DC OUTPUT POWER EFFICIENCY(typ @Full Load) LCVE-060 /square7125 min. norm. Model NO. Part NO. LED Power Supply 170 * 53 * 32 mm 【6.69 * 2.09 * 1.26 inch 】 LCVE-060 /square7125 PLCVE0060 /square7125 Model Name shut down and latch off o/p voltage , re-power on to recover The SCP and OVP will restart automatically after the fault condition is removed TEMP. COEFFICIENT STORAGE TEMPERATURE 130%~160% rated output power ; Hiccp mode -20 to +60 ℃@full load (Refer to output derating curve) -40 to +80 ℃ RELATIVE HUMIDITY

LinkCom Manufacturing Co., Ltd SIZE Model NO. Part NO. LED Power Supply 170 * 53 * 32 mm 【6.69 * 2.09 * 1.26 inch 】 LCVE-060 /square7125 PLCVE0060 /square7125 Model Name ※Reference DERATE Unit :mm 【inch 】 Dimensions