30-LCVE LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
- EMI: Meets FCC / Meets CE
- Comply with Indoor/Outdoor Waterproof (IP 67)
- Warranty: 5 years (refer to LinkCom warranty policy) AC CURRENT INRUSH CURRENT (typ) OVER TEMP. PROTECTION OVER VOLTAGE PROTECTION Shut down and latch off o/p voltage, re-power on to recover
- Safety: Meets UL 81% 0.3±5% 81% Range: 47-63 Hz, Normal: 50-60 Hz TURN ON DELAY TIME O/P NOISE(P-P,V)DC OUTPUT VOLTAGE(V) 0.3 EFFICIENCY ±5% 30W LED Power Supply Constant Voltage Mode 1.2524
- Surge Protection: L-N 1 kV, L/N-FG 2 kV
- AC Input 90~305 Vac Nominal 2.5
- AC Inrush current: 50 A @ 230 Vac Cold start
- Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac 30-LCVE Series OUTPUT VOLTAGE TOLERANCE
- RoHS Compliant PRODUCT SPECIFICATION DC OUTPUT POWER(W) OUTPUT CURRENT(A)MODEL FEATURES:
- Protection: SCP / OVP / OTP / OCP
- High Operating Ambient Temp.: -20 ℃ ~ +60 ℃ > 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load and Rated Output Voltage SCP will restart automatically after the fault condition is removed Cold Start 50 A @ 230 Vac NA 2000 ms, 500 ms at Full Load 115 Vac / 230 Vac
0.6 A / 115 Vac
Meets FCC Part 15 / Meets EN 55015 I/P-O/P: 4.242 kVdc I/P-CASE: 4 kVdc (1) All parameters specified at 230 Vac input unless otherwise noted. WITHSTAND VOLTAGE I/P-O/P: 100M Ω / 500 Vdc / 25℃ / 70% RH EMI 134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】DIMENSION (L*W*H) *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information ISOLATION RESISTANCE LEAKAGE CURRENT < 0.7 mA / 240 Vac OVER CURRENT PROTECTION OCP will restart automatically after the fault condition is removed 90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac SHORT CIRCUIT PROTECTION ACTIVE POWER FACTOR THD INPUT VOLTAGE RANGE LCVE-030U125-00 INPUT FREQUENCY ELECTRICAL SPECIFICATION LCVE-030U240-00 (4) Specified for free-air convection cooling. (2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load. *REFERENCE: www.linkcom.com.tw (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth. (5) Minimum load is NOT required for proper operation . (6) 100% Production Tested. SAFETY -20 ℃ ~ +60 ℃ -40 ℃ ~ +80 ℃ 10% to +90%, non-cond. Meets UL 60950-1 STORAGE TEMP. OPERATING TEMP. RELATIVE HUMIDITY Linkcom Manufacturing Co., Ltd.
Constant Voltage Mode30-LCVE Series *REFERENCE: www.linkcom.com.tw DERATING CURVE DIMENSIONS 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% -20 -10 0 10 20 30 40 50 60 70 LOAD(%) AMBIENT TEMPERTURE(℃) Tc Max. LCVE-030U240 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
Constant Voltage Mode30-LCVE Series Power Factor vs. Load (LCVE-030U125-00) EFFICIENCY vs. LOAD (LCVE-030U125-00) Output Voltage vs. Load (LCVE-030U125-00) 0.50 0.60 0.70 0.80 0.90 1.00 30% 40% 50% 60% 70% 80% 90% 100% 110% Power Factor Load(%) PF vs Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 70% 75% 80% 85% 90% 30% 40% 50% 60% 70% 80% 90% 100% 110% Efficiency (%) Load(%) Efficiency vs Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 11.5 12.5 30% 40% 50% 60% 70% 80% 90% 100% 110% Output Voltage(V) Load(%) Output Voltage vs Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.