80-LCCH LINKCOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

  • Surge protection: L-N 2KV, L-FG/N-FG 4KV
  • Safety: UL 60950 / PSE / CB
  • EMI: FCC Part 15 Class B / CE
  • IP 67 Compliant
  • Warranty: 5 years (refer to warranty policy)
  • RoHS Compliant 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Units Vac Hz A A mA Units V s Units Units %RH %RH g
  • AC Input 100~277VAC
  • Built-in Active PFC Function
  • Protection: SCP / OVP / OTP
  • Flicker Free
  • High Operating Ambient Temp: -30℃~+70℃ 100VAC in FEATURES: Max. Conditions/Description 230VAC in,25℃ Cold start 230VAC in LCCH-080U300 81 24-30 Input Frequency Range 47 Input Specifications Power Factor (Typ.)EFFICIENCY (Typ.) Load Regulation Output Specifications Min. Output Current Regulation Line Regulation ±3 Over Temp Protection (Tc) Weight 1000 Storage Humidity 10 95 Non-condensing Life Time Measured at 277Vac, 45,000 hours at Tc 75°C . Dimensions(L*W*H) 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch Operating Temperature (Ta) -30 70 Non-condensing Operating Case Temperature (Tc) 90 Case temperature measured at the case hot spot Operating Humidity Latching,re-power on to recover Environmental Conditions Min. Max. Conditions/Description Typ. Short Circuit Protection Auto recovery Over Voltage Protection Latching,See individual models OVP levels Turn-on Delay Time 2 *Measured at 100-277VAC and at full load Protection Functions Min. Max. Conditions/DescriptionTyp. Ripple and Noise (pk-pk) 0.5 20MHz Bandwidth. See note (3) Ripple Current <30% of rated output current *Measured at electronic load. Typ. Power Factor (PF) 0.9 100-277VAC,100% loadTotal Harmonics Distortion (THD) Leakage Current 0.45 Input Current 0.95 Inrush Current Max. Conditions/Description Input Voltage Range 90 305 Typ.Min. LCCH-080U480 81.6 1.7 ±5%40-48 ±5% 2.7 ±5% 36-42 2.3 ±5% 18-24 LCCH-080U120 80.4 6.7 LCCH-080U420 79.8 1.9 LCCH-080U360 ±5% DC OUTPUT VOLTAGE (V) 8-12 MODEL DC OUTPUT POWER (W) OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE Constant Current Mode 82.8 Power Supply 80-LCCH Series PRODUCT SPECIFICATION 30-36 LCCH-080U240 81.6 3.4 ±5% Non-condensing Storage Temperature -40 80 Non-condensing Linkcom Manufacturing Co., Ltd.

(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information Power Frequency Magnetic Field IEC 61000-4-6 IEC 61000-4-8 Electrical Fast Transient EN 55015 (CISPR15) , FCC Part 15 Class B EMC Compliance and Safety Electrostatic Discharge (ESD) RF Electromagnetic Field Susceptibility EN 61000-3-2 Class C

8 KV air discharge, 4 KV contact discharge

*REFERENCE: www.linkcom.com.tw (5) Minimum load is NOT required for proper operation . L-N 2KV, L-FG/N-FG 4KV CB Surge Immunity IEC 61000-4-4 IEC 61000-4-5 IEC 61347-2-13 , IEC 61347-1 (4) Specified for free-air convection cooling. EN 61000-3-3 IEC 61000-4-2 Conducted and Radiated Emmission PSE PSE Notes (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. Constant Current Mode IEC 61000-4-3 Conducted RF Disturbances Voltage Fluctuations & Flicker EMS Standards Safety UL UL60950 IEC 61000-4-11Voltage Dips Harmonic Current Emissions EMC Compliance Linkcom Manufacturing Co., Ltd.

*REFERENCE: www.linkcom.com.tw DERATING CURVE Constant Current Mode Linkcom Manufacturing Co., Ltd.

PF vs. Load (LCCH-080U480) Efficiency vs. Load (LCCH-080U480) Output Current vs. Load (LCCH-080U480) Constant Current Mode 0.75 0.8 0.85 0.9 0.95 65% 70% 75% 80% 85% 90% 95% 100% 105% Efficiency (%) Load (%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 0.70 0.80 0.90 1.00 65% 70% 75% 80% 85% 90% 95% 100% 105% Power Factor Load (%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.