Technical content
- EMI: FCC / Meets CE
- Comply with Indoor/Outdoor Waterproof (IP 67)
- Warranty:5 years (refer to LinkCom warranty policy) ±3% 88% 1% Vo(max.) < 1s at Full Load 100-277 Vac 1.5 A / 100 Vac 0.6 A / 277 Vac -40 ℃ ~ +80 ℃ 10% to +90%, non-cond. OVER CURRENT PROTECTION 96 ±3%28-36 90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac ±3%96 32-42 100W Power Supply Constant Current Mode OUTPUT CURRENT(A) 1% Vo(max.) 100-LCCEA Series 18-24 FEATURES:
- RoHS Compliant 88.5% MODEL LCCEA100U360-00 1% Vo(max.) PRODUCT SPECIFICATION 89%
- AC Input 90~305 Vac Nominal
- Built-in Active Power Factor Correction O/P NOISE(P-P,V)DC OUTPUT POWER(W) OUTPUT CURRENT TOLERANCE EFFICIENCYDC OUTPUT VOLTAGE(V) FCC Part15 / Meets EN55015 INPUT VOLTAGE RANGE 2.7 LCCEA100U240-00 LCCEA100U420-00 LCCEA100U480-00 ELECTRICAL SPECIFICATION 36-48 shut down and latch off o/p voltage , re-power on to recover 120%~160% rated output power ; Hiccup mode THD UL 8750 STORAGE TEMP. RELATIVE HUMIDITY 1% Vo(max.) ±3% 2.3 89%
- Protection: SCP / OVP / OTP / OCP
- High Operating Ambient Temp.: -30 ℃ ~ +50 ℃
- Surge Protection: L-N 6 kV
- Safety: UL *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information < 20% at 80%-Full Load 100-277 Vac *REFERENCE: www.linkcom.com.tw > 0.9 @ Full Load 100-277 Vac ISOLATION RESISTANCE DIMENSION (L*W*H) Cold Start 65 A @ 230 Vac < 0.75 mA -30 ℃ ~ +50 ℃ @ Full Load 100-277 Vac INRUSH CURRENT (Max.) SCP and OVP will restart automatically after the fault condition is removedOVER VOLTAGE PROTECTION SAFETY 232 * 46.5 * 31 mm【9.13 * 1.83 * 1.22 inch】 (4) Specified for free-air convection cooling. (6) 100% Production Tested. I/P-O/P: 3.75 kVac, O/P-Grnd: 0.5 kVac, I/P-Grnd: 1.88 kVac I/P-O/P, I/P-FG,O/P-FG :100M Ω / 500 Vdc / 25℃ / 70% RH INPUT FREQUENCY Range: 47-63 Hz, Normal: 50-60 Hz ACTIVE POWER FACTOR WITHSTAND VOLTAGE OPERATING TEMP. LEAKAGE CURRENT OVER TEMP. PROTECTION (5) Minimum load is NOT required for proper operation . TURN ON DELAY TIME AC CURRENT SHORT CIRCUIT PROTECTION (1) All parameters specified at 230 Vac input unless otherwise noted. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. EMI Linkcom Manufacturing Co., Ltd.
Constant Current Mode100-LCCEA Series *REFERENCE: www.linkcom.com.tw DIMENSIONS Tc Max. LCCEA100U240 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
Constant Current Mode100-LCCEA Series Output Current vs. Load(LCCEA100U240-00) THD vs. Load(LCCEA100U240-00) Efficiency vs. Load(LCCEA100U240-00) 80.0% 82.0% 84.0% 86.0% 88.0% 90.0% 70% 75% 80% 85% 90% 95% 100% 105% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 10% 15% 20% 70% 75% 80% 85% 90% 95% 100% 105% THD (%) Load(%) THD vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 4.000 4.020 4.040 4.060 4.080 4.100 70% 75% 80% 85% 90% 95% 100% 105% Output Current (A) Load(%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.
Constant Current Mode100-LCCEA Series Power Factor vs. Load(LCCEA100U240-00) 0.80 0.85 0.90 0.95 1.00 1.05 70% 75% 80% 85% 90% 95% 100% 105% Power Factor Load(%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.