60W-LCCEA LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
- EMI: Meets FCC / Meets CE
- Comply with Indoor/Outdoor Waterproof (IP 67)
- Warranty: 5 years (refer to LinkCom warranty policy)
- RoHS Compliant 4.6 OUTPUT CURRENT TOLERANCE EFFICIENCY O/P NOISE(P-P,V) 84% > 0.95 @ 115 Vac / > 0.9 @ 230 Vac at Full Load 90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac 0.75 mA / 132 Vac / 60 Hz TURN ON DELAY TIME *REFERENCE: www.linkcom.com.tw WITHSTAND VOLTAGE DIMENSION (L*W*H) (2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load. (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Minimum load is NOT required for proper operation . (6) 100% Production Tested. 158 * 58 * 39.4 mm 【6.22 * 2.28 * 1.55 inch】 *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information (1) All parameters specified at 230 Vac input unless otherwise noted. AC CURRENT EMI -20℃ ~ +60℃ ISOLATION RESISTANCE FEATURES: SCP, OVP and OTP will restart automatically after the fault condition is removed Cold Start 50 A @ 230 Vac OVER VOLTAGE PROTECTION LEAKAGE CURRENT Range: 47-63 Hz, Normal: 50-60 Hz ELECTRICAL SPECIFICATION < 20% @ 277 Vac Full Load 3 s at Full Load 115 Vac / 230 Vac INRUSH CURRENT (Max.) INPUT VOLTAGE RANGE Meets FCC Part15 / Meets CE EN55015 NA NA 60W LED Power Supply Constant Current Mode NA SAFETY OPERATING TEMP. STORAGE TEMP. RELATIVE HUMIDITY OVER CURRENT PROTECTION 60-LCC Series 42-48 33-42 33-36 PRODUCT SPECIFICATION 1.7LCCEA060U172-00 LCCEA050U432-00 -40℃ ~ +80℃ 10% to +90%, non-cond. UL 8750 INPUT FREQUENCY ACTIVE POWER FACTOR 9-12 0.8 A / 115 Vac 0.4 A / 230 Vac OVER TEMP. PROTECTION THD SHORT CIRCUIT PROTECTION LCCEA060U132-00 LCCEA060U142-00 4.3 62.4 OUTPUT CURRENT(A)MODEL DC OUTPUT POWER(W) DC OUTPUT VOLTAGE(V) 1.458.8 61.2 51.6
- AC Input 90~305 Vac Nominal
- Power Factor: > 0.95 @ 115 Vac / > 0.9 @ 230 Vac @ Full Load
- Protection: SCP / OVP / OCP 4.2 ±5% 86%1.3 86%
- High Operating Ambient Temp.: -20℃ ~ +60℃
- Surge Protection: L-N 1 kV, L/N-FG 2 kV
- Safety: UL ±5% ±5% 86% 3.6 ±5% Linkcom Manufacturing Co., Ltd.
Constant Current Mode60-LCC Series *REFERENCE: www.linkcom.com.tw DIMENSIONS Tc LCCEA060U142 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
Constant Current Mode60-LCC Series Output Current vs. Load (LCCEA060U132-00) Efficiency vs. Load (LCCEA060U132-00) THD vs. Load (LCCEA060U132-00) 1.290 1.300 1.310 1.320 Output Current (A) Load(%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 80.0% 82.0% 84.0% 86.0% 88.0% 90.0% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 10% 15% 20% THD (%) Load(%) THD vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.
Constant Current Mode60-LCC Series PF vs. Load (LCCEA060U132-00) 0.75 0.80 0.85 0.90 0.95 1.00 Power Factor Load(%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.