45-LCCE LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
- Surge Protection : L-N 1KV, L-FG/N-FG 2KV
- Safety: UL 60950-1
- EMI: CE / FCC
- Comply with Indoor/Outdoor Waterproof (IP 67) 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Units Vac Hz A A mA Units V s Units Units %RH %RH g Typ. Power Factor (Typ.)
- AC Input 100 ~ 277 Vac
- Built-in Active Power Factor Correction
- Protection: SCP / OVP / OTP
- High Operating Ambient Temp.: -20 ℃ ~ +60 ℃ 32-42 18-24 Output Specifications ±2.5 Typ. Life Time Storage Temperature -40 80 LCCE-045U132 46.8 27-36 Dimensions(L*W*H) 163 * 47 * 31.6 mm Weight 403 Non-condensing Storage Humidity 10 95 Non-condensing Operating Temperature (Ta) -20 60 Non-condensing Operating Case Temperature (Tc) N/A Operating Humidity 10 Over Temp Protection (Tc) Auto recovery Environmental Conditions Min. Max. Conditions/Description Short Circuit Protection Auto recovery Over Voltage Protection Auto recovery Turn-on Delay Time 3 *Measured at 110/230VAC and at full load Protection Functions Min. Max. Conditions/Description Ripple and Noise (pk-pk) 4.5 20MHz Bandwidth. See note (3) Ripple Current N/A Load Regulation Output Current Regulation -5 5 Min. Max. Conditions/Description Line Regulation Typ. Power Factor (PF) 0.9 100-230VAC,100% loadTotal Harmonics Distortion (THD) N/A Inrush Current 43 230VAC in,25℃ Cold start Leakage Current 0.75 264VAC in Input Frequency Range 47 63 Input Current 100VAC in0.7 Input Specifications Min. Max. Conditions/Description Input Voltage Range 90 305 Typ. LCCE-045U232 46 2.3 ±5% LCCE-045U302 45 3 ±5% 15-20 11.2-15 LCCE-045U192 45.6 1.9 ±5% 1.3 ±5% OUTPUT CURRENT TOLERANCE DC OUTPUT VOLTAGE (V) 36-48 LCCE-045U112 46.2 1.1 ±5% ±5% Constant Current Mode EFFICIENCY (Typ.) LCCE-045U152 45 23-30 1.5 LCCE-045U951
- RoHS Compliant 45.6 PRODUCT SPECIFICATION FEATURES:
- Warranty: 5 years (refer to LinkCom warranty policy) Non-condensing ±5% Power Supply 45-LCCE Series N/A LCCE-052U132 52.5 31.5-42 1.25 ±5% MODEL 0.95 DC OUTPUT POWER (W) OUTPUT CURRENT (A) Linkcom Manufacturing Co., Ltd.
(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information IEC 61000-4-2 IEC 61000-4-3 Conducted RF Disturbances Safety UL Voltage Dips UL 60950-1 IEC 61000-4-11 EN 55015 (CISPR15) , FCC part 15 Class B EN 61000-3-2 Class C EN 61000-3-3 PSE Comply with PSE Notes (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Minimum load is NOT required for proper operation . *REFERENCE: www.linkcom.com.tw Power Frequency Magnetic Field IEC 61000-4-6 IEC 61000-4-8 RF Electromagnetic Field Susceptibility Electrical Fast Transient Surge Immunity IEC 61000-4-4 IEC 61000-4-5 L-N 1KV, L-FG/N-FG 2KV EMC Compliance and Safety EMC Compliance Conducted and Radiated Emmission Harmonic Current Emissions Constant Current Mode Voltage Fluctuations & Flicker EMS Standards Electrostatic Discharge (ESD) 8 KV air discharge, 4 KV contact discharge Linkcom Manufacturing Co., Ltd.
*REFERENCE: www.linkcom.com.tw DERATING CURVE Constant Current Mode Tc Max. Linkcom Manufacturing Co., Ltd.
Output Current vs. Load (LCCE-045U112) Efficiency vs. Load (LCCE-045U112) PF vs. Load (LCCE-045U112) Constant Current Mode 1.000 1.050 1.100 1.150 70% 75% 80% 85% 90% 95% 100% 105% Output Current (A) Load(%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 75% 80% 85% 90% 70% 75% 80% 85% 90% 95% 100% 105% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 0.60 0.70 0.80 0.90 1.00 70% 75% 80% 85% 90% 95% 100% 105% Power Factor Load(%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.