15-LCCE LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
- Surge Protection : L-N 1KV
- Safety: UL 60950-1 / PSE
- EMI: CE / FCC
- Comply with Indoor/Outdoor Waterproof (IP 67) 100VA C 120VA C 200VA C 277VA C 100VA C 120VA C 200VA C 277VA Units Vac Hz A A mA Units V s Units Units %RH %RH g N/A 100-230VAC,100% load ±10% Power Factor (Typ.) 0.5 ±10% 1.2 ±10% 16.8 38-48 0.35 ±10% 18 11-15 Min. ±10% 16 14-20 0.8 ±10% 0.7 Max. Conditions/Description ±10% 14.4 14-20 0.72 ±10% 0.516 18.9 16.8 LCCE-015U501 LCCE-017U701 24-32 13-18 19-24 LCCE-017U501 LCCE-017U351 30-36 LCCE-015U721 LCCE-017U142 LCCE-017U112 LCCE-017U801 13-18 Typ. Typ.
- AC Input 100~277VAC
- Built-in Active Power Factor Correction
- Protection: SCP / OVP / OTP
- High Operating Ambient Temp.: -20 ℃ ~ +60 ℃ 9-12 ±10% DC OUTPUT VOLTAGE (V) 5-8
- Warranty: 5 years (refer to LinkCom warranty policy)
- RoHS Compliant Output Specifications Life Time Storage Temperature -40 80 Non-condensing Storage Humidity 10 LCCE-013U721 12.96 13-18 ±10 Dimensions(L*W*H) 95 * 40 * 25 mm Weight 138
95 Non-condensing
Operating Temperature (Ta) -20 60 Non-condensing Operating Case Temperature (Tc) N/A Operating Humidity 10 Over Temp Protection (Tc) The power will derate on the current limit. Environmental Conditions Min. Max. Conditions/Description 105 Short Circuit Protection Auto recovery Over Voltage Protection Latching,See individual models OVP levels Turn-on Delay Time 3 *Measured at 115/230VAC and at full load Protection Functions Min. Max. Conditions/Description Ripple and Noise (pk-pk) 3 20MHz Bandwidth. See note (3) Ripple Current N/A Load Regulation Output Current Regulation Min. Max. Conditions/Description Line Regulation Typ. Power Factor (PF) 0.9 Total Harmonics Distortion (THD) Inrush Current 5 230VAC in,25℃ Cold start Leakage Current 0.7 264VAC in Input Current 110VAC in0.4 Input Frequency Range 47 63 1.05 Input Specifications Input Voltage Range 90 305 Typ. LCCE-017U122 LCCE-015U112 15.75 1.05 ±10% LCCE-015U801 14.4 0.8 ±10% 11-15 ±10% LCCE-013U351 12.6 0.35 ±10% 0.72 ±10% LCCE-013U112 MODEL DC OUTPUT POWER (W) OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE 11.2 1.4 Non-condensing Constant Current Mode EFFICIENCY (Typ.) LCCE-013U501 12 12.6 1.05 FEATURES: N/A 19-24 ±10% Power Supply 15-LCCE Series 30-36 LCCE-013U142 PRODUCT SPECIFICATION 0.5 Linkcom Manufacturing Co., Ltd.
(1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information IEC 61000-4-2 IEC 61000-4-3 UL EN 55015 (CISPR15) , FCC part 15 Class B EN 61000-3-2 Class C EN 61000-3-3 Safety Voltage Dips PSE PSE Notes (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Minimum load is NOT required for proper operation . *REFERENCE: www.linkcom.com.tw UL 60950-1 IEC 61000-4-11 Conducted RF Disturbances Power Frequency Magnetic Field IEC 61000-4-6 IEC 61000-4-8 RF Electromagnetic Field Susceptibility Electrical Fast Transient Surge Immunity IEC 61000-4-4 IEC 61000-4-5 L-N 1KV EMC Compliance and Safety EMC Compliance Conducted and Radiated Emmission Harmonic Current Emissions Constant Current Mode Voltage Fluctuations & Flicker EMS Standards Electrostatic Discharge (ESD) 8 KV air discharge, 4 KV contact discharge Linkcom Manufacturing Co., Ltd.
*REFERENCE: www.linkcom.com.tw DERATING CURVE Constant Current Mode Tc Max. LCCE-015U501 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
Power Factor vs. Load (LCCE-015U112) Efficiency vs. Load (LCCE-015U112) Output Current vs. Load (LCCE-015U112) Constant Current Mode 0.80 0.85 0.90 0.95 1.00 65% 70% 75% 80% 85% 90% 95% 100% 105% Power Factor Load(%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 65.0% 70.0% 75.0% 80.0% 85.0% 65% 70% 75% 80% 85% 90% 95% 100% 105% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 0.900 0.950 1.000 1.050 1.100 65% 70% 75% 80% 85% 90% 95% 100% 105% Output Current (A) Load(%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.