It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Technical Data: LB10003PNLME/PSNME LB12503PNLME/PSNME AC-22 Enclosed Door Interlocked Switch-Disconnector R Bureau Vertitas R KEMA Certified R EN60947-1&3 R IP65 Data Range Units LBD10003PNLME LBD10003PSNME LBD12503PNLME LBD12503PSNME Rated thermal current Ith at 40°C Amps A 1000 1250 Rated insulation voltage Ui Volts V 1000 Rated dielectric strength Volts kV 8 Rated impulse voltage Uimp Volts kV 12 Rated operational current Ie at 400V AC-22A Amps A 1000 1250 Rated operational current Ie at 400V AC-23A Amps A 1000 Rated operational power Pe at 400V AC-23A Watts kW 554 Rated breaking capacity at 400V AC23A Amps A 8000 Rated making capacity at 400V AC23A Amps A 10000 Rated short circuit making capacity (peak value) Icm Amps kA 60 Rated short-time withstand current (1 sec) rms Icw Amps kA 25 Minimum number of mechanical operations - Cycles 10000 Terminal Capacity (rigid copper cable) - mm² 2x300 Lug bolt size - - M14 Tightening torque - Nm 45
Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Terminal Configuration Enclosure Dimensions Technical Data: LB10003PNLME/PSNME LB12503PNLME/PSNME AC-22 Enclosed Door Interlocked Switch-Disconnector 1 3 5 N 2 4 6 N LB 3 Pole + Switched Neutral 1 3 5 2 4 6 LB 3 Pole LB10003PNPS_Layout 1 18/06/2014 14:07 Page 2
Technical Data: LB10003PNLME/PSNME LB12503PNLME/PSNME AC-22 Enclosed Door Interlocked Switch-Disconnector Padlock Operation: Door Interlock Defeat Mechanism (For Authorised Personnel Only): WARNING! ACCESS TO LIVE PARTS . Ensure that the door is closed and the handle is in the on position . Locate the hole on the right side of the handle, then push and hold a small pin into the hole to activate the defeat mechanism . The door can now be opened in the on position. Remove pin and close the door to reset the mechanism Handle Assembly: 1. Ensure that the handle is in the off position and locate the handle on to the door with the handle showing the off position at 9 o’clock 2. Tighten the four M5 flange nuts to 1.5Nm Shaft Assembly: 3. Ensure that the switch is in the off position and fully insert the shaft into the switch with the cross pin in a horizontal position 4· Tighten the M5 shaft grub screw to 1.2Nm using a 2.5mm A/F allen key Fuse Shroud Assembly: (SWITCH FUSE ONLY) 5/6. Install the four upright shrouds into the corresponding clips 7. Install fuse shroud into the corresponding clips Press hereLift here Press here 1. 2. 3. 4. 5. 6. LB10003PNPS_Layout 1 18/06/2014 14:07 Page 3 Europa House. Airport Way, Luton. Beds, LU2 9NH Tel 01582 692 440 I Fax 01582 692 450 e-mail sales@Juropacomponents corn website http//www europacomponents corn