NEW Calibrated Xenon Light Source L7810

FEATURES

l Light Intensity Drift (Typ.) l Comparison of Spectral Irradiance (Reference data) : 50 cm away from light source Stability is one of the important characteristics of calibrated light sources. Hamamatsu’s excellent cathode technology and optimized lamp housing realize high stability and good repeatability. n High Power A Xenon lamp emits high intense UV, visible and IR light so that a reliable measurement can be possible even in the range of 300 nm to 400 nm, where either a deuterium lamp or a tungsten lamp doesn’t deliver enough light. is a logo mark for an accreditation system based on Japanese Meas- urement Law. Our Planning & Engi- neering Division is accredited in accordance with ISO/IEC Guide 25: 1990 in the field of photometry cali- bration. (Our accreditation number is 0081.) [JCSS: Japan Calibration Service System (The Japanese Goverment accreditation scheme for calibration laboratories and a signatory of APLAC Mutual Recognition Arrange- ment)] s LEFT: LAMP HOUSING, RIGHT: POWER SUPPLY OPERATING TIME (h) RELATIVE INTENSITY (%) 10 200 110 100 30 40 50 60 70 80 90 100 110 CONVENTIONAL HALOGEN LAMP CONVENTIONAL DEUTERIUM LAMP CALIBRATED XENON LIGHT SOURCE 200 250 300 350 400 450 500 550 600 650 700 750 800 0.001 0.01 0.1 100 WAVELENGTH (nm) SPECTRAL IRRADIANCE ( µW·cm -2·nm-1) TLSOB0065EA TLSOB0063EA

JUN. 2000 SI Printed in Japan(1000) Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2000 Hamamatsu Photonics K.K Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. SPECIFICATIONS DIMENSIONAL OUTLINES (Unit: mm) HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: Lough Point, 2 Gladbeck Way, Windmill Hill, Enfield, Middlesex EN2 7JA, United Kingdom, Telephone: 44(20)8-367-3560, Fax: 44(20)8-367-6384 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it HOMEPAGE URL http://www.hamamatsu.com Lamp Input Wattage Spectral Distribution Calibrated Range A Type of Calibration Calibration Unit Stability Window Material (Lamp Housing) Warm-up Time Recommended Calibration Period B Guaranteed LifeC Fluctuation (p-p) Drift NOTE: AThe calibrated value is the light power at 50 cm away from front surface of lamp housing. BThis is the recommended calibration period when high reliability is required. Please contact to our sales office for re-calibration fee. CThis is the guaranteed time the unit satisfies requirements as calibrated light source. DThis is an accessory coming with the unit. Xenon Lamp 150 W 185 nm to 2000 nm 250 nm to 800 nm Spectral Irradiance µW .cm -2.nm -1 1.0 % Max. ±0.5 %/h Max. Synthetic Silica 10 min 100 hours or 1 year whichever comes first 500 hours Input Voltage (switched manually) Power Consumption Cooling (Lamp Housing, Power Supply) Ambient Temperature Humidity Dimensions (W × H × D) Weight Lamp Housing Power Supply Case D Lamp Housing Power Supply Case D

100 Vac/115 Vac/200 Vac/230 Vac

(±10 %), 50/60 Hz 500 VA Forces Air Cooling (cooling fan is included) 0 °C to 40 °C 30 % to 90 % 100 mm × 280 mm × 100 mm 144 mm × 176 mm × 280 mm 595 mm × 425 mm × 345 mm Approx. 3.5 kg Approx. 10 kg Approx. 7.8 kg 100 COOLING FAN M37 P=1 OUTPUT WINDOW ( 28) 140 280 5 100 5 [FRONT VIEW] [BOTTOM VIEW] [SIDE VIEW] CONNECTOR * SIDE COVER MOUNTING SCREW 4-M3 HEX SOCKET HEAD BOLT SIDE COVER (REMOVE THIS COVER WHEN REPLACING LAMP) 4-M4 PLASTIC FEET ARE ATTACHED TO THE BOTTOM OF THE UNIT BUT CAN BE REMOVED TO USE THEIR HOLES FOR INSTALLATION OF THE LAMP HOUSING. REFERENCE SURFACE OF CALIBRATION * For cable to connect lamp housing with power supply, length: 2000 CURRENT SEL M 1A/125V TIME COUNTER 0.0 XENON LAMP POWER SUPPLY hours LAMP ON 7.5 8.0 8.5 POWER [Adc] POWER INTER LOCK OVER HEAT [FRONT VIEW] [SIDE VIEW] [REAR VIEW] OUTPUT SN. VOL. SEL100/115/200/230 50/60 HZ 144 176 280 CONNECTOR * AC INPUT CONNECTOR TLSOA0066EA TLSOA0067EA LAMP HOUSING POWER SUPPLY