RELATIVE RADIANT INTENSITY (%) 100 0 500 1000 1500 2000 2500 3000 OPERATING TIME (h) L5431 CONVENTIONAL TECHNOLOGY Crystalization of fused silica envelope has occured after 500 hours or so operation, which will reduce the light transmission. HAMAMATSU TECHNOLOGY Double halogen cycle convection will supress the dissipation of the electrodes. CONVENTIONAL LAMP SHORT-ARC TYPE METAL HALIDE LAMP 575W L5431 Long Life / 3000 hours

FEATURES

The Short-Arc Metal Halide Lamp, L5431, suited for the light source for projector, has achieved the average life time of 3000 hours. It will enhance the performance of LCD projector and over-head projector (OHP). LIFE CHARACTERISTICS Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subjected to change without notice. No patent rights are granted to any of the circuits described herein. © 1997 Hamamatsu Photonics K. K. TLSOB0029EA PATENT PENDING

SHORT-ARC TYPE METAL HALIDE LAMP 575W L5431 DIMENSIONAL OUTLINE (Unit:mm) TLSOA0014ED HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205, Telex: 4225-186HAMAHQ Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 United Kingdom:Hamamatsu Photonics UK Limited: Lough Point, 2 Gladbeck Way, Windmill Hill, Enfield, Middlesex EN2 7JA, United Kingdom, Telephone: (44)181-367-3560, Fax: (44)181-367-6384 North Europe: Hamamatsu Photonics Norden AB: Färögatan 7, S-164-40 Kista, Sweden, Telephone: (46)8-703-29-50, Fax: (46)8-750-58-95 Italy: Hamamatsu Photonics Italia S.R.L.: Via Della Moia, 1/E 20020 Arese, (Milano), Italy, Telephone: (39)2-935 81 733, Fax: (39)2-935 81 741 TLSOC0018EA LONG LIFE MECHANISM HAMAMATSU has developed a unique technology (PAT- ENT PENDING), called as double halogen cycle, which extends the average lamp life over 3000 hours. SPECIFICATION Lamp Power 575 W Lamp Voltage AC 95 V Lamp Current AC 6.1 A Luminous Flux 49,000 Im Luminous Efficiency 85 Im/W Color Temperature 6,000 K Arc Gap 7.0 mm Life (Expectancy) 3,000 hours SPECTRAL DISTRIBUTION * PATENT PENDING: JAPAN 17, USA 4, EUROPE 4 QUARTZ GLASS ARC ELECTRODE OUTER EFFECTINNER EFFECT 100 300 400 500 600 700 800 RELATIVE OUTPUT INTENSITY (%) WAVELENGTH (nm) 200 TLSOB0018EA TLSO1011E03 NOV. 1997 Created in Japan UNIQUE “DOUBLE HALOGEN CYCLE” TECHNIQUE Outer gas convection suppresses the thermal reaction with the fused silica envelope thus protect it from crystallization. It maintains the envelope strength and light transmission even after 500 hours of operation. Inner gas convection assures the metal halogen cycle which minimize the electrode dissipation. 135–5 25.0–0.5 115.0–0.2 7.0–0.5 10.0–0.2 21.0–0.5