[Applicable objects]

  • Semiconductor device
  • Electronic component
  • Printed circuit board
  • Ceramic
  • Plastic component
  • Die casting
  • Metal component GNon-destructive inspection GX-ray CT GFocal spot size: 5 µm (at 4 W) The focal spot of 5 µm of the sealed type X-ray tube offers sharp and clear X-ray images even at a high magnification. GHigh power: Maximum output 75 W GExternal control via RS-232C interface GHigh speed ramping-up Ramping-up speeded up to 3 times faster than conventional 150 kV microfocus X-ray source. GNo high voltage cable connection required High voltage power supply is integrated.
  • This microfocus X-ray source generates X-rays harmful to the human body. Use sufficient caution when handling the equipment to avoid direct or inadvertent exposure to X-rays. Install the X-ray source or the X-ray tube unit in an X-ray shielded cabinet or room equipped with safety interlock functions t o prevent accidental exposure to X-rays. OPERATIONAL CAUTION
  • This microfocus X-ray source generates X-rays and must therefore be used only under the supervision of qualified personnel.
  • This microfocus X-ray source shall be used in compliance with health and safety regulations enforced in order to prevent healt h hazards problems due to ionizing radiation. IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 SPECIFICATIONS GENERAL X-RAY TUBE UNIT X-RAY CONTROL UNIT 1See the graph of the X-ray tube voltage / current operation range. 2Reference value: With 50 % of maximum X-ray emission. 3This weight includes the accessories of approx. 1.5 kg. 4The control software is provided as a sample software for the purpose of MFX operation. The performance of the software is not guaranteed. NOTE: X-ray tube voltage setting range X-ray tube current setting range X-ray tube voltage operational range X-ray tube current operational range 1 Maximum output X-ray focal spot size (Nominal value) X-ray beam angle 2 Focus to object distance (FOD) Rated output Communication method Small Focus Mode Middle Focus Mode Large Focus Mode Small Focus Mode Middle Focus Mode Large Focus Mode 0 to 150 0 to 500 40 to 150 10 to 500 7 (5 µm at 4 W) Approx. 43 Approx. 17 Continuous rating Interface: RS-232C (9-pin D-sub connector) kV µA kV µA W µm degree mm Description / Value UnitParameter X-ray output window material / Thickness Target naterial Operating ambient temperature Storage ambient temperature Operating and storage humidity Weight Beryllium / 0.2 Tungsten +10 to +40 0 to +50 20 to 85 (No condensation) Approx. 13.5 µm kg Description / Value UnitParameter Input voltage (AC) Power consumption Operating ambient temperature Storage ambient temperature Operating and storage humidity Weight Single phase 100 to 240 (50 Hz / 60 Hz) Less than 220 +10 to +40 0 to +50 20 to 85 (No condensation) Approx. 6 V W kg Description / Value UnitParameter REGULATION AND STANDARDS RoHS directive EMC Safety EN 50581 Category 9 IEC/EN 61010-1 Description UnitParameter CONTROL SOFTWARE Applicable PC Applicable OS Interface PC / AT compatible Windows ® XP, 7 RS-232C interface Description UnitParameter

X-RAY TUBE VOLTAGE / CURRENT OPERATION RANGE DIMENSIONAL OUTLINES (Unit: mm) TXPRB0021EB X-RAY CONTROL UNIT C12163 X-RAY TUBE UNIT L8122-01 TXPRA0015EA TXPRA0014EB POWER INTER LOCK X-RAY ON ERROR X-RAY150 CONTROL UNIT INTER LOCK 2 CONTROL OUTPUT POWER AC INPUT FUSL 14 .0/250V INTER LOCK 1RS-232C MONITOR RS-232C CONTROL 426 ± 2 482 ± 2 99 ± 212 AC POWER INPUT CONNECTOR COOLING FUN 100 MIN. 33 Max. (CONNECTOR) 40 300 ± 23 0 CONNECTION CABLE LENGTH: 5 m 100 ± 0.5 100 MIN. 140 ± 2 11 100 ± 0.5 298 ± 2 200 ± 0.5 23 70 ± 2 228 ± 2 FOD 17 200 ± 0.532 43°43°

19.5 COOLING FAN

300 ± 2 3 × M3 DEPTH 5 X-RAY BEAM ANGLE X-RAY FOCAL SPOT COOLING FAN PROTECTIVE EARTH TERMINAL 4 × M6 DEPTH 8 (MOUNTING SCREW HOLES) 4 × M6 DEPTH 8 (MOUNTING SCREW HOLES) CONTROL CONNECTOR 600 400 500 200 300 100 * The X-ray tube voltage guaranteed range is 40 kV to 150 kV. * Operation is not guaranteed when the tube current is below 10 µA. 60 80 100 120 14050 70 90 110 130 150 MIDDLE FOCUS MODE SMALL FOCUS MODE LARGE FOCUS MODE TUBE CURRENT (µA) TUBE VOLTAGE (kV)

NOV. 2015 IP

RELATED PRODUCTS

Windows® is a registered trademark of Microsoft Corporation in the United States and/or other countries. Other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners. FOS (Fiber optic plate coated with X-ray scintillator) IStructure The FOS is an optical device for X-ray imaging, fabricated by coating an X-ray scintillator material over a fiber optic plate consisting of more than tens of million glass fibers each a few micrometers in diameter. The FOS provides higher sensitivity and resolutio n than currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commerciall y available CCD. The fiber optic plate used in the FOS has excellent X-ray absorption characteristics, so that X-rays penetrating the X-ray scintillator and directly entering the CCD are minimized to less than 1 %. This protects the CCD from the deterioration and in- creased noise caused by X-ray irradiation, assuring a long service life and maintaining high image quality. Various sizes and shapes of FOS are available to meet your particular needs, including tapered FOP types. X-RAY IMAGE INTENSIFIER DIGITAL CAMERA UNIT C7336-05/-52 The C7336 series consist of a high resolution, high contrast 4-inch X-ray image in- tensifier (X-ray I.I.) and a 2.8 megapixel CMOS image sensor. The X-ray I.I. used has a fixed field-of-view of 100 mm diameter or a 4 inches/2 in- ches adjustable field-of-view and an input window made of thin aluminum which is excellent in X-ray transmission and causes less scattering of X-rays. These features allow real-time detection at X-ray energy levels from about 20 keV. The captured images can be transferred to PC directly by interface of IEEE1394b. X-CUBE™ (COMPACT X-RAY CCD CAMERA) H8480, H8481, H8953 X-CUBEs are compact X-ray CCD camera designed for non-destructive inspection, which make X-ray imaging as easy as an ordinary CCD camera in handling. The H8480 and H8953 use a 2/3 type CCD coupled to large-diameter tapered FOPs which are coated with CsI. The H8481 uses a straight type FOP instead of the large FOP, achieving a high resolution of 20 Lp/mm. Left: H8480 Center: H8953 Right: H8481 2D Image-Device Protection Film FOP (Fiber optic plate) Scintillator : CsI(Tl) TXPRF0020 TMCPF0072 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2015 Hamamatsu Photonics K.K. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. HAMAMATSU PHOTONICS K.K. HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se