DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

[Applicable objects]

  • Electronic component
  • Printed circuit board
  • Plastic component
  • Metal component
  • Food
  • Beverage
  • Medicine & drug
  • Bioproduct
  • Small animal, insect GHigh power: Maximum output 50 W GHigh stability GExternal control via RS-232C interface GNo high voltage cable connection required High voltage power supply is integrated. GIn-line X-ray inspection GNon-destructiveinspection GX-ray CT X-RAY SOURCE
  • This microfocus X-ray source generates X-rays harmful to the human body. Use sufficient caution when handling the equipment to avoid direct or inadvertent exposure to X-rays. Install the X-ray source or the X-ray tube unit in an X-ray shielded cabinet or room equipped with safety interlock functions t o prevent accidental exposure to X-rays. OPERATIONAL CAUTION
  • This microfocus X-ray source generates X-rays and must therefore be used only under the supervision of qualified personnel.
  • This microfocus X-ray source shall be used in compliance with health and safety regulations enforced in order to prevent healt h hazards problems due to ionizing radiation. IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 SPECIFICATIONS GENERAL X-RAY TUBE UNIT X-RAY CONTROL UNIT X-ray tube voltage setting range X-ray tube current setting range X-ray tube voltage operational range X-ray tube current operational range 1 Maximum output X-ray focal spot size (Nominal value) 2 X-ray beam angle 3 Focus to object distance (FOD) Rated output Communication method 0 to 110 0 to 800 40 to 110 10 to 800 15 to 80 Approx. 62 Approx. 16.8 Continuous rating Interface: RS-232C (9-pin D-sub connector) kV µA kV µA W µm degree mm Description / Value UnitParameter X-ray output window material / Thickness Target material Operating ambient temperature Storage ambient temperature Operating and storage humidity Weight Beryllium / 0.5 Tungsten +10 to +40 0 to +50 20 to 85 (No condensation) Approx. 8.5 mm kg Description / Value UnitParameter Input voltage (DC) Power consumption Operating ambient temperature Storage ambient temperature Operating and storage humidity Weight +24 (+2.4, -0) Less than 120 +10 to +40 0 to +50 20 to 85 (No condensation) Approx. 5.5 V W kg Description UnitParameter NOTE: REGULATION AND STANDARD RoHS directive EMC EN 50581 Category 9 — Description UnitParameter CONTROL SOFTWARE Applicable PC Applicable OS Interface PC / AT compatible Windows ® XP, 7 RS-232C interface Description UnitParameter 1See the graph of the X-ray tube Voltage / Current operation range. 2This focal spot size changes depending on the output. 3Reference value: With 50 % of maximum X-ray emission. 4This weight includes the accessories of approx. 2 kg. 5The control software is provided as a sample software for the purpose of MFX operation. The performance of the software is not guaranteed.

X-RAY TUBE VOLTAGE / CURRENT OPERATION RANGE DIMENSIONAL OUTLINE (Unit: mm) TXPRA0003EB TXPRA0004EA TXPRB0028EA X-RAY CONTROL UNIT C10953 X-RAY TUBE UNIT L10952 33 MAX. (CONNECTOR) 299 ± 2(10) 121 ± 2 230 ± 2 140 MIN. 220 ± 2 120 ± 2245 ± 2140 MIN.100 ± 0.510 150 ± 0.5 41.5 FOD 16.8 X-RAY BEAM ANGLE 62° X-RAY BEAM ANGLE 31° 31° 60 ± 1 155.5 ± 2.0 60 ± 0.5 71 ± 1 100 ± 0.5 150 ± 0.510.5 4 × M6 DEPTH 8 (MOUNTING SCREW HOLES) PROTECTIVE EARTH TERMINAL4 × M6 DEPTH 8 (MOUNTING SCREW HOLES) X-RAY FOCAL SPOT COOLING FAN 4 × M3 DEPTH 8 X-RAY FOCAL SPOT CONNECTION CABLE LENGTH: 5 m 60 ± 0.5 * The X-ray tube voltage guaranteed range is 40 kV to 110 kV. * Operation is not guaranteed when the tube current is below 10 µA. TUBE VOLTAGE (kV) TUBE CURRENT (µA) 500 600 700 800 900 400 300 200 100 50 60 70 80 90 100 110

NOV. 2015 IP

RELATED PRODUCTS

Windows® is a registered trademark of Microsoft Corporation in the United States and/or other countries. Other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners. FOS (Fiber optic plate coated with X-ray scintillator) IStructure The FOS is an optical device for X-ray imaging, fabricated by coating an X-ray scintillator material over a fiber optic plate consisting of more than tens of million glass fibers each a few micrometers in diameter. The FOS provides higher sensitivity and resolutio n than currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commerciall y available CCD. The fiber optic plate used in the FOS has excellent X-ray absorption characteristics, so that X-rays penetrating the X-ray scintillator and directly entering the CCD are minimized to less than 1 %. This protects the CCD from the deterioration and in- creased noise caused by X-ray irradiation, assuring a long service life and maintaining high image quality. Various sizes and shapes of FOS are available to meet your particular needs, including tapered FOP types. X-RAY IMAGE INTENSIFIER DIGITAL CAMERA UNIT C7336-05/-52 The C7336 series consist of a high resolution, high contrast 4-inch X-ray image in- tensifier (X-ray I.I.) and a 2.8 megapixel CMOS image sensor. The X-ray I.I. used has a fixed field-of-view of 100 mm diameter or a 4 inches/2 in- ches adjustable field-of-view and an input window made of thin aluminum which is excellent in X-ray transmission and causes less scattering of X-rays. These features allow real-time detection at X-ray energy levels from about 20 keV. The captured images can be transferred to PC directly by interface of IEEE1394b. X-CUBE™ (COMPACT X-RAY CCD CAMERA) H8480, H8481, H8953 X-CUBEs are compact X-ray CCD camera designed for non-destructive inspection, which make X-ray imaging as easy as an ordinary CCD camera in handling. The H8480 and H8953 use a 2/3 type CCD coupled to large-diameter tapered FOPs which are coated with CsI. The H8481 uses a straight type FOP instead of the large FOP, achieving a high resolution of 20 Lp/mm. Left: H8480 Center: H8953 Right: H8481 2D Image-Device Protection Film FOP (Fiber optic plate) Scintillator : CsI(Tl) TXPRF0020 TMCPF0072 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2015 Hamamatsu Photonics K.K. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. HAMAMATSU PHOTONICS K.K. HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se