KD7 LUMEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Export department: Tel.: +48 68 45 75 139 / /276/ 386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMeL s.A. ul. sulechowska 1 65-022 Zielona Góra PoLAnd WWW.LUMEL.COM.PL KD7 screen recorder gaLVanic iSoLation: inPUtS: oUtPUtS: Digital interfaceSupply featUreS: Examples of measuring data presentation Various forms of data display:

  • linear diagrams,
  • digital indicators,
  • analog views,
  • bargraphs,
  • tables and others. (manual and automatic switching between screens.) Password protection Example of application System of measurement, control and recording of temperature and energy with wireless communication. DC
  • Intuiti ve servicing - LCD TFT 5.7’’ screen, with touch panel.
  • Data archiving on CompactFlash card, capacity up to 4 GB.
  • IP65 protecti on grade on the front panel.
  • Up to 24 measuring channels.
  • 12 analog inputs (programmable and standard).
  • 6 or 32 alarms outputs.
  • 8 or 16 digital inputs.
  • 4 or 8 analog outputs.
  • Visualizati on of measurements in digital form, analog indica- tors, diagrams, bargraphs.
  • RS-232, RS-485 and USB serial interfaces.
  • ETHERNET communicati on, WWW and FTP server, MODBUS SLAVE TCP/IP .
  • MS Windows® CE operati ng system.
  • PC soft wares: KD7 SETUP , KD CHECK, KD CONNECT, KD ARCHIVE.
  • Diversifi ed user’s access rights.
  • Menu available in various language versions . MR03 N100 pulse output KD7SM2 MR03 MR03 RS485 RS485 Pt100 Pt100 Visualizati on Recording Reporti ng Selecti on of the language Currently measured quanti ti es Frequency to restore pages Selecti on of the channel group radio USB RS - 485 RS - 232 Ethernet SM3 RS485 RS 485 MOD BUS USB IP65 RS 232 RTC - U Af(x) 485RS MASTER pulse radio

See alSo: Export department: Tel.: +48 68 45 75 139 / /276/386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Góra POLAND WWW.LUMEL.COM.PL External features Supply voltage Humidity < 70% condensation inadmissible Rated operating conditions Display field LCD 5.7’’ TFT type 320 x 240 pixels, with touch screen Overall dimensions 144 x 144 mm panel cut-out dimensions: 138+1 x 138+1 mm Weight < 2 kg Protection grade from frontal side: IP65 from terminal side: IP20 Safety and compatibility requirements Electromagnetic compatibility noise emissions acc. to EN 61000-6-4 noise immunity acc. to EN 61000-6-2 Isolation between circuits 500 V d.c. acc. to EN 61010-1 Isolation between supply and measuring system 2 kV Pollution level 2 Installation category II Maximal operating voltage in relation to earth for the measuring system, relays and supply: 500 V acc. to EN 61010-1 Altitude above sea level < 2000 m Inputs Input signal Measuring range/ Accuracy class (%) Minimal subrange/ Accuracy class (%) Voltage 0 .. ±9999 mV 0.15 5 mV 0.25 Current 0 .. ±20 mA 0.15 1 mA Thermocouple (TC): J (Fe-CuNi) -200 .. 1200°C 0.1 100°C 1 K (NiCr-NiAl) -200 .. 1370°C 130°C 0.7 N (NiCrSi-NiSi) -200...1300°C 200°C 0.5 E (NiCr-CuNi) -200...1000°C 100°C 1 R (PtRh13-Pt) 0 .. 1760°C 0.2 540°C 0.3 S (PtRh10-Pt) 0 .. 1760°C 570°C 0.3 B (PtRh30-PtRh6) 400 .. 1820°C 0.2 1000°C 0.2 K (GOST) -200 .. 1370°C 130°C 0.7 Resistance transmitter (RTD): Pt 100 -200 .. 850°C 0.15 50°C 0.25 Pt 500 0.3 0.5Pt 1000 0.3 Ni 100 -60 .. 180°C 0.15 0.25 Cu 100 -50 .. 180°C GR.21 (GOST’78) (GOST’94) -260 .. 1100°C50P (GOST’78) (GOST’94) 100P (GOST’78) 100P (GOST’94) -200 .. 200°C50M (GOST’78) (GOST’94) 100M (GOST’78) (GOST’94) Potentiometric transmitter 50 .. 2000 W 100 W Resistance transmitter 0 .. 2000 W 100 W Logic input control signal 0/5 .. 24 V d.c. switching frequency up to 50 Hz SoftwareS aSSiSting the kd7 recorder work: KD ARCHIVE Software desti- ned to review and analyse archive data from the recorder on a PC computer, stored in a binary format with digital signature. KD7 SETUP Software destined to configure recorder settings by means of a PC computer. KD7 screen recorder Digital interface Interface type Properties RS-485 2 interfaces: MODBUS Slave and Master, baud rate 0.3 .. 256 kbit/s, transmission mode ASCII/ RTU RS-232 interface: MODBUS Slave, baud rate 0.3 .. 256 kbit/s, transmission mode ASCII/ RTU USB Device V.1.1, socket USBB-G ETHERNET 10 Base-T, socket RJ45, MODBUS Slave TCP/IP , FTP and WWW server Outputs Output type Properties Relay - electromagnetic relays:  250 V a.c./1 A or  30 V d.c./1 A - OptoMOS relays:  85 V d.c., 100 mA or  60 V a.c., 70 mA Output to supply object transducers - 2 outputs 24 V d.c./ 30 mA

Export department: Tel.: +48 68 45 75 139 / /276/ 386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Góra POLAND WWW.LUMEL.COM.PL Review of archive data through the PC computer - KD ARCHIVE. KD7 configuration through the PC computer -KD SETUP . Verification of the digital signature of text data - KD CHECK. Exemplary functions of kd8 assisting softwares Downloading and erasing of archive data by means of the PC computer - KD CONNECT. KD CONNECT Software destined for the communication between the recorder and the PC computer through the USB interface in order to download archive data and record/erase on the CF card. KD CHECK Software destined to verify the digital signa- ture in archive data stored in text format. Checking result: incorrect file verification Backlighting of the selected measuring channel diagram. SoftwareS aSSiSting the kd7 recorder work: KD7 screen recorder

See aLSo: Export department: Tel.: +48 68 45 75 139 / /276/386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMeL s.A. ul. sulechowska 1 65-022 Zielona Góra PoLAnd WWW.LUMEL.COM.PL Ordering Temperature sensors. For more information about LUMEL's products please visit our website: www.lumel.com.pl KD7-19M/2 KD7 screen recorder Programmale transducer of temperature and humidity - P18. Controllers. Screen Recorder KD7 X X X X X X X X X X X Measuring inputs (Slot 1): without measuring inputs 0 6 programmable measuring inputs 1 6 standard measuring inputs: 0..10 V 2 6 standard measuring inputs: 0..20 mA 3 6 standard measuring inputs: 4..20 mA 4 6 standard measuring inputs: 3 x 0..10 V + 3 x 0..20 mA 5 6 standard measuring inputs: 3 x 0..10 V + 3 x 4..20 mA 6 3 programmable measuring inputs 7 Measuring inputs (Slot 2): without measuring inputs 0 6 programmable measuring inputs 1 6 standard measuring inputs 1) 2..6 3 programmable measuring inputs 7 Interface measuring input: with RS-485 (1) interface measuring input 1 Digital signals/analog outputs (Slot 3): without digital signals and analog outputs 0 8 alarms (NO relays) + 8 alarms (OptoMos) 1 8 alarms (NC relays) + 8 alarms (OptoMos) 2 8 digital inputs + 4 analog outputs: 0..5 mA 3 8 digital inputs + 4 analog outputs: 0..20 mA 4 8 digital inputs + 4 analog outputs: 4..20 mA 5 8 digital inputs + 4 analog outputs: 0..5 V 6 8 digital inputs + 4 analog outputs: 0..10 V 7 Digital signals/analog outputs (Slot 4): without digital signals and analog outputs 0 8 alarms (NO relays) + 8 alarms (OptoMos) 1 8 alarms (NC relays) + 8 alarms (OptoMos) 2 8 digital inputs + 4 analog outputs 2) 3..7 Interfaces: USB 1 USB + Ethernet + RS-485 (2) 2 USB + Ethernet + RS-232 3 Memory for measuring data: with a 4 GB CF card 6 as per order X Supply: Recorder fi rmware: without mathemati cal functi ons 3) 0 with mathemati cal functi ons 1 Soft wares servicing the recorder from PC: KD Connect, KD Check 1 KD Connect, KD Check, KD Archive, KD7 Setup 2 Acceptance tests: without extra quality inspecti on requirements 8 with an extra quality inspecti on certi fi cate 7 with calibrati on certi fi cate 4 according to customer’s request X 1) Write the range code from the item 2...6 as above: (Slot 1) 2) Write the range code from the item 3...7 as above: (Slot 3) 3) A key for the activation of mathematical functions can be ordered separately Example of order: the code KD7 11100161118 means: KD7 recorder, (Slot 1) with 6 programmable measuring inputs, (Slot 2) with 6 programmable measuring inputs, with RS-485 interface measuring input, (Slot 3) without digital and analog outputs, (Slot 4) without digital signals and analog outputs, with USB interface, with a 4 GB CF memory card, supply: 90 .. 253 V a.c., with mathematical functions, with KD Connect and KD Check softwares, without extra quality inspection requirements.