KD6 LUMEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
www.lumel.com.pl EXAMPLE OF APPLICATION KD6 - SCREEN RECORDER
- Up to 60 logical channels (max. up to 8 analog channels).
- Input:
- measuring programmable (0,4 or 8),
- binary (2 or 6),
- digital Modbus RTU Master (10 devices up to 10 registers).
- Outputs:
- relays (2, 6 or 8),
- analog 0/4...20mA (0, 4 or 8),
- supplying output 24V d.c. / 30mA,
- digital RS-485 Modbus.
- Graphical color display: LCD TFT 3.5’’ , 320 x 240 pixels, fully configurable by a user.
- Archiving of measured parameters in the internal file system memory with a capacity of 8GB.
- Data logging in the form of CSV.
- Extensive alarm, math and scaling functions.
- Data presentation in digital form, in form of analog indicators, line charts, bargraphs.
- Independent recording for each group of logical channels (interval, registration trigger mode.
- Built-in USB HOST 2.0.
- Modern and user-friendly Ethernet interface 10/100 BASE-T:
- protocol: MODBUS TCP/IP , HTTP , FTP ,
- services: www server, ftp server, DHCP client.
- Programming of parameters using free eCon software.
- NTP client for synchronization with a time server.
- Overall dimensions: 96 x 96 x 77 mm. 4-20 mA max. 8 Ethernet TCP IP Ethernet www/ ftp RS-485 .CSV GLOBAL MONITORING GLOBAL MONITORING GLOBAL MONITORING KD6 RS-485 KD6 P43 CURRENT, VOLTAGE, POWER, THD MEASUREMENT Monitoring of engine operating parameters. PLC encoder vibration sensor bearing temp. sensor winding temp. sensor 0-10V 4-20mA Pt100 Pt1000 max. 8 inputs LOCAL MONITORING max. 8 outputs 10 devices x 10 registers USB HOST CAT III VV V Electrical Safety
www.lumel.com.pl DIGITAL INTERFACE Interface type Properties RS-485 1x Modbus Master/Slave interface 1x Modbus Slave interface Transmission mode Modbus RTU: 8N2, 8E1, 8O1 Address:1...247 Ethernet Modbus TCP/IP , NTP protocoll WWW server, FTP server, DHCP client 10/100 Base-T RJ45 socket USB HOST 2.0 TECHNICAL DATA ADDITIONAL INPUTS Binary inputs 2 or 6 inputs; 0 V d.c. – inactive binary input, KD6 - SCREEN RECORDER GALVANIC ISOLATIONFEATURES NTP Ochrona hasłem RS 485 0/4..20 Am Ethernet INPUTS OUTPUTS IP65 Af(x) EXTERNAL FEATURES Readout field graphical color display: LCD TFT 3.5’’ , 320 x 240 pixels Overall dimensions 96 x 96 x 77 mm panel cut-out dimensions: 92.5 x 92.5 mm Weight 0.3 kg Protection grade fron frontal side: IP65 from terminal side: IP20 DC 485RS MASTER RS 485Zasilanie OUTPUTS Output type Properties Analog current: 0/4 .. 20 mA programable, load resistance ≤ 400 Ω Relays 2, 6, 8 relays, NOC, load 250V / 0,5A a.c. or 30V / 5A d.c. Suplying output 1x output 24V d.c. /30 mA INPUTS Sensor type / Input signal Standard Range Basic error RTD PT100 EN 60751:2009 0.2% Fe-CuNi (J) EN 60584-1:2014 Voltage ±10 V, ±300 mV, ±75 mV,
10 V, 300 mV, 75 mV,
Current ±40 mA, 40 mA Resistance R 0...4000 Ω
www.lumel.com.pl KD6 - SCREEN RECORDER SAFETY AND COMPABILITY REQUIREMENTS Electromagnetic compatibility noise immunity acc. to EN 61000-6-2 noise emissions acc. to EN 61000-6-4 Isolation between circuits basic acc. to EN 61010-1 Polution level 2 acc. to EN 61010-1 Installation category III acc. to EN 61010-1 Maximal phase-to-earth voltage
- for supply circuit and relay outputs 300 V
- for measuring input 50 V
- for circuits of RS-485, Ethernet, analog outputs: 50 V acc. to EN 61010-1 Altitude a.s.l. < 2000 m RATED OPERATING CONDITIONS Preheating time 30 min. Ambient temperature -10…23…55°C, K55 class acc. to EN61557-12 Operating position any Additional error (in % of the basic error) from ambient temperature change: < 50% / 10°C DATA VISUALISATION Easy to use and intuitive menu; information bar with status of: logical group archiving, USB port status, status of used memory storage, Ethernet and RS-485 interface, time and data. Various forms of data presentation:
- line charts
- digital indicators
- analog view
- bargraphs up to 10 programmable screens (6 parameters per page); ability to change color for all screens Available colors for digital indications:
www.lumel.com.pl KD6 - SCREEN RECORDER RECORDER CONFIGURATION WITH FREE eCON SOFTWARE ability to configure and update of KD6 with free eCon software (via RS-485 or Ethernet interface) Saving the configuration to a file and loading to many of the same recorders or creating a backup copy. REMOTE READOUT OF PARAMETERS THROUG ETHERNET: WWW SERVER, FTP www server for remote reading of current measurement data; FTP server for downloading archived data in CSV files
www.lumel.com.pl ORDERING CODE KD6 - SCREEN RECORDER KD6 X X X XX X X I/O module – slot X*: 4 x programmable measuring inputs 4 I/O module – slot Y: without module 0 6 x relay outputs 1 4 x relay outputs + 4 x binary inputs separated from each other 2 4 x analog outputs + 4 x binary inputs with common ground 3 4 x programmable measuring inputs 4 Supply voltage: Version: standard 00 custom-made** XX Language: Polish/English M other* X Acceptance tests: with test certificate 0 with calibration certificate 2 acc.to customer’s request** X KD6-19_en LUMEL S.A. ul. Słubicka 4, 65-127 Zielona Góra, Poland tel.: +48 68 45 75 100, fax +48 68 45 75 508 www.lumel.com.pl Export department: tel.: (+48 68) 45 75 130, 45 75 131, 45 75 132 e-mail: export@lumel.com.pl Calibration & Attestation: e-mail: laboratorium@lumel.com.pl Technical support: tel.: (+48 68) 45 75 143, 45 75 141, 45 75 144, 45 75 140 e-mail: export@lumel.com.pl * all possible variants for slot X are described in the user manual in chapter 11 ** only after agreeing with the manufacturer For more information about Lumel products please visit our website: www.lumel.com.pl Join us at Facebook!