OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS DL0125 Rev 2 7.5KW INVERTER GENERATOR MODEL NO: IG8000 PART NO: 8877135
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to operate the machine, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service. Ensure the generator and its components suffered no damage during transit and that all components are present. Should any loss or damage be apparent, please contact your CLARKE dealer immediately. GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERAL SAFETY RULES & SYMBOLS SAFETY SYMBOLS Read Instruction manual before use DANGER - highly flammable liquid. Caution - The user should be aware of a general hazard Engine and exhaust become hot during use - DO NOT touch Dangerous voltage. Risk of electric shock Poisonous fumes - DO NOT use in an enclosed space. Wear ear defenders Wear protective gloves. Wear a protective facemask. WARNING: Loud noise. DO NOT use in rain, snow or damp conditions.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com WORK AREA 1. ALWAYS use in a well ventilated area. 2. ALWAYS position the exhaust outlet away from people. 3. NEVER use indoors or in a confined space. 4. ALWAYS keep children away from the generator. POSITIONING THE GENERATOR 1. ALWAYS leave a least a 1m gap between the generator and any surrounding building or structures. 2. ALWAYS ensure the generator is on a dry, solid, level and flat surface. 3. ALWAYS ensure the surrounding area is free from any material that could burn or be damaged by heat. 4. NEVER move or tilt the generator whilst it is switched on. FIRE PREVENTION 1. ALWAYS switch the engine OFF when refuelling. Allow generator to cool for at least 2 minutes before removing the fuel cap. Loosen cap slowly to relieve pressure in the tank. 2. ALWAYS refuel away from any source of heat. 3. ALWAYS refuel in a well ventilated area. 4. ONLY use standard unleaded petrol. 5. DO NOT overfill the fuel tank. DO NOT fill to the very top of the tank and leave room for petrol expansion. 6. NEVER smoke whilst refuelling and avoid smoking or using a naked flame near the generator. 7. DO NOT operate near an open flame, heat or flammable materials. This generator may emit highly flammable and explosive petrol vapours. 8. NEVER start the engine if there is spilled fuel. Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine. PREVENTION OF ELECTRIC SHOCK 1. NEVER use the generator in wet conditions unless it is well protected/covered. Under these conditions, adequate ventilation MUST be provided. 2. NEVER operate the generator with wet hands. 3. NEVER use water or any other liquids to clean the generator.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 4. ALWAYS ground the generator before using it to maximise safety, see ‘Ground The Generator’ section on pages 15. 5. ALWAYS use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. Extension cords with an in-line GFCI are recommended for these operations. ADDITIONAL SAFETY RULES FOR GENERATORS 1. ALWAYS ensure the applied load does not exceed the generator rating. Overloading the generator is dangerous and could cause damage. 2.ALWAYS disconnect and switch off the generator when carrying out any maintenance. 3. ALWAYS ensure the generator reaches operating speed before connecting a load. 4. NEVER allow the generator to run out of fuel when a load is connected. 5. NEVER transport the generator with fuel in the tank. 6. DO NOT connect to a commercial or residential power supply; e.g. ring main. 7. DO NOT touch hot parts. This generator produces heat when running. Temperatures near the exhaust can exceed 150°F/65°C. Allow the generator to cool down after use before touching the engine or areas of the generator that become hot during use. 8. If any part of the generator, electrical device or power cable is broken, damaged or defective, make sure it is repaired or replaced before using. Service or repair of the generator should only be performed by a qualified technician. 9. NEVER modify the generator in any way. Modifying or using the generator for any other purpose for which it is not designed may result in serious injury, machine damage and voiding of the warranty. 10.ALWAYS turn off all connected electrical devices before stopping the generator. 11.ALWAYS turn the engine switch to the ‘OFF’ position when the engine is not running. 12.NEVER carry or lift the generator using the handle assembly.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERATOR OVERVIEW
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CONTROL PANEL OVERVIEW NO DESCRIPTION NO DESCRIPTION
1 Fuel Gauge, Voltage & Load
8 13A, AC 230V 3 Pin Plug Outlets
2 Low Idle Switch 9 Parallel Operation Outlet
3 DC 5V USB Outlet 10 Ground Earthing Point
4 DC 12V Adaptor Outlet &
11 Fuel Switch
5 13A Circuit Breaker x 2 12 Main SW Switch ON/OFF Button 6 31A Circuit Breaker 13 Engine STOP/START Button 7 32A, AC 230V 3 Pin Plug Industrial Outlet
14 Output, Overload Alarm & Low Oil
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com UNPACKING Unpack your generator and check to ensure the following items are present. Should there be any deficiency or damage caused during transit contact your CLARKE dealer immediately. BEFORE USING THE GENERATOR Before using your generator check that the generator is:
- In good condition and free from any damage.
- Clean and free from fuel or oil spillage.
- Correctly located for use. NO DESCRIPTION NO DESCRIPTION 1 Tool Pouch 5 12 Volt D.C. output lead assembly with positive (red, ‘+’) and negative (black ‘-’) crocodile clips
2 Spark Plug Spanner 6 Oil Funnel
3 Spark Plug Spanner Arm 7 Remote Control x 2
4 Cross Head Screwdriver
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com KNOW YOUR GENERATOR LOW IDLE This generator is equipped with a low idle switch. Engaging this switch allows the system to regulate the engine speed and automatically adjust its fuel consumption to match the required load. When the electrical load changes, the generator engine will automatically speed up and slow down as needed. This reduces fuel consumption and noise levels, while extending runtime and the engines lifespan. Keep this switch engaged (ON) only when the power load requirement is less than 75% of the rated watts. DO NOT engage the switch when the total load is more than 75% of rated watts. The generator engine must run at full speed to supply power for anything over 75% of rated watts. PARALLEL OPERATION The parallel operation outlet allows you to connect two of these generators together to increase the total available electrical power. Follow the instructions included with the parallel operation kit for correct installation and operation. NOTE: The Parallel Operation Kit is not supplied with this generator. Contact your CLARKE dealer for more information. CIRCUIT BREAKERS The circuit breakers protect the individual AC and DC circuits. The AC circuit breaker will activate when the AC outlets exceed their maximum current. The DC circuit breaker will activate when the DC 12V and/or 5V USB outlet exceed their maximum current. When the circuit breaker activates, turn off and disconnect the device(s) from the respective outlets and press the circuit breaker to reset. NOTE: The 31A circuit breaker may activate if there is a power issue with the 13A circuits. This is so that all circuits are protected in case of a power
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com surge. Both the 31A & both 13A circuit breakers need to be in the ‘ON’ position for power to be taken from the 13A sockets. Always check and reset all circuit breakers after any power issue on any circuit. CONNECTING ELECTRICAL DEVICES Follow the steps below to properly connect your device(s) to the generator. 1. Before connecting electrical devices, allow the generator to run for a few minutes to stabilise the speed and voltage output. 2. Select the device with the highest wattage and make sure it is turned off. Plug the device into the generator and then turn the device on. Allow the engine to stabilise. 3. Repeat step 2 to plug in each additional device. DO NOT attempt to plug in and start multiple devices at the same time. GENERATOR CAPACITY Make sure the generator can supply enough running (rated) and starting (max.) watts for the items you will power at the same time. Follow these simple steps. 1. Select the items you will power at the same time. 2. Total the running (rated) watts of these items. This is the amount of power the generator must produce to keep the items running. 3. Estimate how many starting (max.) watts you will need. Starting wattage is the short burst of power needed to start electric motor driven tools such as a circular saw or refrigerator. Because not all motors start at the same time, total starting (max.) watts can be estimated by adding only the items with the highest additional starting (max.) to the total rated watts. Example: Total Running Watts: 1180 Highest Starting Watts: +1275 Total Starting Watts Needed = 2455 Tool/ApplianceRunning Watts Additional Starting Watts Refrigerator 700 1350 Portable Fan 40 120 Laptop 250 250 46 in. Flat Screen TV 190 190
1180 Total Running Watts 1275 Highest Starting Watts
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity as previously described. The chart below serves as a reference for the estimated wattage requirements of com- mon electrical devices. however, DO NOT solely reply on this chart, all electronics and appliances are built differently, ALWAYS check the wattage listed on the electrical device before consulting this chart: Tool/ApplianceRated (Running) WattsSurge (Starting) Watts Hot Plate 2500 0 Saw - Circular 1500 1500 Saw - Mitre 1200 1200 Microwave 1000 0 Well Water Pump 1000 1000 Sump Pump 800 1200 Refrigerator Freezer 800 1200 Computer 800 0 Television 500 0 Box Fan 300 600 Light Bulb 75 0
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERATOR PREPARATION STEP 1 - ADD/CHECK OIL NOTE: THE GENERATOR IS SHIPPED WITHOUT OIL ADDED. The user must add the proper amount of oil before operating the generator for the first time. The oil capacity of the engine crankcase is 1litre (35.2 fl.oz). NOTE: Depending on outside working temperature, to find out which oil to use, consult the chart shown. To add oil, follow these steps: 1. Place the generator on a level surface. Make sure the engine is OFF before adding or checking oil. 2. Loosen the screws on the left side access cover and remove the cover from the side panel as shown. Unscrew the yellow oil dipstick from the engine.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 3. Using the oil funnel or appropriate dispenser, slowly add oil as shown, being careful not to overfill the unit. Fill the crankcase to the upper fill line so you can visually see the oil coming halfway up the oil fill threads. 4. Refit the oil dipstick and firmly tighten it. Wipe clean any spilled oil. NOTE: Used engine oil should be disposed of at an approved disposal site. See local authority recycling for more information. For subsequent operation, the oil level should be checked before each use, or after every 8 hours of operation. The generator is equipped with a low oil sensor and will not start without a sufficient amount of oil. TO CHECK OIL LEVEL (BEFORE EVERY SUBSEQUENT START) 1. Place the generator on a level surface. Make sure the engine is OFF before adding or checking oil. 2. Open the oil access cover. Remove and wipe the dipstick with a clean rag. 3. Insert the dipstick into the oil fill without screwing it in. Remove the dipstick and check the oil mark. 4. If the oil mark covers less than one half of the dipstick, slowly add oil until the oil mark reaches to the top of the dipstick (or when you can see the oil coming halfway up the oil fill threads). 5. Wipe clean any oil leaks and firmly tighten the dipstick. Reinstall the oil access cover. STEP 2 - ADD/CHECK FUEL Use only fresh (within 30 days from purchase), lead-free petrol with a minimum of 87 (E10) octane rating. The generator performs best with ethanol-free petrol. DO NOT use petrol with over 10% ethanol. The capacity of the fuel tank is 26 Litres
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com (5.7 gallons). DO NOT MIX OIL WITH THE PETROL. To add petrol, follow these steps: 1. Make sure the generator is shut OFF and on a level surface. Unscrew the fuel cap, as shown, and set it aside. The fuel cap may be tight and hard to unscrew. 2. Slowly add unleaded petrol to the fuel tank. Be careful not to overfill and only fill to the marked fill line on the fuel level indicator. NOTE: DO NOT fill the fuel tank to the very top. If you do so, petrol will expand and spill during use, even with the fuel cap in place. 3. Reinstall the fuel cap and wipe clean any spilled petrol with a dry cloth. NOTE: During operation, the fuel level will be displayed on the data centre of the control panel, or check the fuel gauge. If the fuel level is low, refill the fuel tank before starting your generator for the next time. STEP 3 - CONNECT THE BATTERY The generator is shipped with the lead acid battery’s negative (black, ‘-’) WARNING: KEEP GENERATOR AWAY FROM OPEN FLAME. THIS GENERATOR MAY EMIT HIGHLY FLAMMABLE AND EXPLOSIVE PETROL VAPOUR, WHICH CAN CAUSE SEVERE BURNS OR EVEN DEATH IF IGNITED. A NEARBY OPEN FLAME CAN LEAD TO EXPLOSION EVEN IF NOT DIRECTLY IN CONTACT WITH THE PETROL. WARNING: ENSURE THERE IS ADEQUATE FUEL IN THE TANK WHEN USING THE GENERATOR. RUNNING OUT OF FUEL OR STOPPING THE ENGINE SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE. CAUTION: ALWAYS USE EYE PROTECTION WHEN HANDLING BATTERIES AND WASH YOURS HANDS AFTER HANDLING.
- Keep battery away from sparks, cigarettes or other sources of flame.
- Connect & disconnect battery only when generator is OFF and in well ventilated areas.
- Keep out of reach of children.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com terminal disconnected to maximise safety. To start the generator using the electric start, the battery must be connected. To connect the battery, follow these steps: 1. Loosen the screws to the right side maintenance cover. Remove cover and set aside. 2. Connect the red wire to the positive (+) terminal first, then connect the black wire to the negative (-) terminal. Make sure all connections are tight. NOTE: Be careful not to short across the terminals when installing. Shorting the terminals together can cause sparks, damage the battery and/or generator and can cause burns or explosions. 3. Reinstall and secure the maintenance cover. NOTE: If you do not plan to use the generator for a long period of time, we recommend to disconnect the negative (black, ‘-’) battery cable from the battery to protect the battery from losing charge. After disconnecting the cable, cover the free end with an insulator such as electrical tape. You may also choose to use a trickle charger (not included) to maintain battery charge. STEP 4 - GROUND THE GENERATOR To reduce the risk of electric shock and to maximise safety, the generator should be properly grounded. Ground the generator by connecting a grounding wire to the grounding nut on the front control panel and tighten. A generally acceptable ground- ing wire is a No.14 SWG (Standard Wire Gauge) stranded copper wire. This grounding wire should be connected at the other end to a copper, brass or steel grounding rod that is driven into the earth. Wire and grounding rods are not included with the generator. NOTE: Grounding codes can vary by location. Contact a local electrician to check the area codes.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com STARTING YOUR GENERATOR Before starting the generator, make sure you have read and performed the steps in the ‘Generator Preparation’ section (pages 12-15) of this manual. ALWAYS use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCI’s are available in-line with some extension cables. CAUTION: DISCONNECT ALL ELECTRICAL LOADS FROM THE GENERATOR BEFORE ATTEMPTING TO START. BEFORE STARTING THE GENERATOR: 1. Verify that the generator is outside on a dry, level surface. Allow at least 1m of clearance on all sides of the generator. 2. To maximise safety, check that the generator is properly grounded (see above). 3. Check there is sufficient level of oil in the crankcase. Add oil if necessary. 4. Make sure there is sufficient level of petrol in the fuel tank. Add fuel if necessary, see pages 13-14. 5. Make sure all electrical devices are unplugged from the generator during ignition. Otherwise it will be difficult for the engine to start. TO START THE GENERATOR, PERFORM THE FOLLOWING STEPS: 1. Turn the LOW IDLE MODE switch to the ‘OFF’ position. NOTE: If you wish to use the Low Idle Mode, turn the switch to the ‘ON’ position after the engine has warmed up for 2 - 3 minutes. 2. Turn the MAIN SWITCH to the ‘ON’ position. WARNING: GENERATOR EXHAUST EMISSIONS CONTAINS CARBON MONOXIDE (CO). THIS IS A POISONOUS GAS YOU CANNOT SEE OR SMELL. IF YOU CAN SMELL THE GENERATOR EXHAUST, YOU ARE BREATHING IN CO GAS.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 3. Turn the FUEL SWITCH to the ‘ON’ position as shown. After completing steps 1 to 3, there are three ways to start the generator, either by Electric One Button Start, Remote Control or Manual Recoil Start, as follows: ELECTRIC ONE BUTTON START & REMOTE CONTROL 1. Hold down the ENGINE START/STOP button for 5 seconds. NOTE: If the engine does not start, release the button, wait 10 seconds and try again. Keeping the button compressed for too long can damage the starter. NOTE: If you have repeated failed attempts to start the engine, please consult the troubleshooting guide on pages 28-29. 2. Alternatively, hold down the ENGINE START button on the remote control for 5 seconds. 3. Allow the generator to run for several minutes before attempting to connect any electrical devices. This allows the generator to stabilise its speed and temperature. MANUAL RECOIL START NOTE: Use the Recoil Starter when the battery voltage is too low to turn the starter motor.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 1. Pull the Starter Grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. NOTE: DO NOT allow the grip to snap back after starting; return it gently to its original position. 2. Allow the generator to run for several minutes before attempting to connect any electrical devices. This allows the generator to stabiles its speed and temperature. SHUTTING OFF THE GENERATOR WARNING: ALLOW THE GENERATOR TO COOL DOWN BEFORE TOUCHING AREAS THAT BECOME HOT DURING USE. CAUTION: ALLOWING PETROL TO SIT IN THE FUEL TANK FOR LONG PERIODS OF TIME CAN MAKE IT DIFFICULT TO START THE GENERATOR IN THE FUTURE. NEVER STORE THE GENERATOR FOR EXTENDED PERIODS OF TIME (OVER 2 MONTHS) WITH FUEL IN THE TANK. REFER TO ‘STORING THE GENERATOR’ ON PAGE 25 1. Turn off all electrical devices prior to unplugging them from the generator. Unplugging running devices can cause damage to the generator. 2. Allow the generator to run at no load for a few minutes to stabilise the internal temperature. 3. Turn the ‘MAIN SWITCH’ to the ‘OFF’ position. 4. Turn the FUEL switch to the ‘OFF’ position.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com MAINTENANCE Proper routine maintenance of the generator will help prolong the life of the machine. Please perform maintenance checks and operations according to the Maintenance Schedule below. If there are any questions about the maintenance procedures listed in this manual, please contact the CLARKE service centre. NOTE: Maintenance should be performed more often under dusty conditions or operating under heavy load. WARNING: NEVER PERFORM MAINTENANCE OPERATIONS WHILE THE GENERATOR IS RUNNING. BEFORE MAINTENANCE OR SERVICING THE GENERATOR, TURN OFF THE GENERATOR, DISCONNECT ALL DEVICES AND ALLOW THE GENERATOR TO COOL DOWN RECOMMENDED MAINTENANCE SCHEDULE BEFORE EACH USE AFTER 1ST MONTH OR
20 HRS
50 HRS
100 HRS
300 HRS
(Pages 12-13 & 24) Check Level X Replace X X Air Filter (Page 20) Check X Clean X Replace X Spark Plug (Page 21) Check/ Clean/Regap X Replace X Idle Speed Check/ Adjust X Fuel Tank (Page 22) Drain/Clean X Fuel FilterInspect X Replace X Fuel HoseCheck X Spark Arrester (page 22) Clean X
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com IMPORTANT GENERATOR MAINTENANCE TIPS:
- Drain the carburettor after each use and before storage to prevent it from clogging.
- DO NOT store the generator with fuel inside the tank for more than 2 months - fuel will go bad.
- Run the generator for at least 20 minutes every month to charge the battery and maximise the generators lifespan. NOTE: Failure to properly maintain the generator will void the warranty. AIR FILTER MAINTENANCE Check every 50 hours of operation (refer to recommended maintenance schedule). Routine maintenance of the air filter helps maintain proper airflow to the carburettor. Occasionally check that the air cleaner is free of excessive dirt. TO INSPECT AND CLEAN THE AIR FILTER: 1. Loosen the screws to the right side maintenance cover. Remove cover and set aside 2. Unsnap the air filter cover clip, pull the cover down and off the unit (A). 3. Remove the air filter cover and set aside (B). 4. Remove the air filter (C). 5. Wash the air filter with warm, soapy water. Rinse and squeeze dry. Leave to dry thoroughly before reinstalling 6. Reinstall the air filter back into the unit and replace the cover. 7. Reinstall the air filter unit back into the engine compartment and replace the maintenance cover. NOTE: Running the engine with a dirty, damaged or missing air filter element can result in danger to the operator and cause the engine to wear out prematurely.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SPARK PLUG MAINTENANCE The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation. If the engine is hot, allow it to cool before servicing the spark plug (refer to recommended maintenance schedule). TO INSPECT OR REPLACE THE SPARK PLUG: 1. Unscrew the maintenance cover knob and remove the cover from the side panel. 2. Remove the spark plug cap. 3. Use the included spark plug spanner to unscrew and then carefully remove the spark plug from the engine. NOTE: There is limited space for the spanner to turn, use the arm to gain leverage to loosen the plug. 4. Visually inspect the spark plug. If it is cracked or chipped, or if the electrodes are worn or burned, discard it and replace with a new spark plug. 5. If re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base, then re-gap the spark plug. 6. Measure the plug gap with a spark plug gap gauge. The gap should be Carefully adjust the gap if necessary. 7. Screw the spark plug back into the spark plug hole using the spark plug spanner. DO NOT over-tighten the spark plug. Recommended tightening a spark plug is 1/2 to 4/3 of a turn (15ft/lb torque/20.33Nm) after the spark plug gasket contacts the spark plug hole. 8. Reinstall the spark plug cap and maintenance cover. SPARK ARRESTOR MAINTENANCE Inspect and clean the spark arrestor every 100 hours of operation (refer to recommended maintenance schedule). The spark arrestor is located outside the muffler, which gets very hot during operation. Allow the engine and the muffler to cool completely before servicing the spark arrestor.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TO INSPECT AND CLEAN THE SPARK ARRESTOR: 1. Remove the left maintenance cover, then loosen the jubilee clip holding the arrestor cover in place and remove the arrestor from its housing. 2. Use a brush to remove carbon deposits from the spark arrestor screen. Be careful to avoid damaging the screen. The spark arrestor must be free of breaks and tears. Replace the spark arrestor if it is damaged. 3. Install the spark arrestor in the reverse order of removal. DRAINING THE FUEL TANK/CARBURETTOR To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburettor before storing. TO DRAIN THE FUEL TANK & CARBURETTOR: 1. With the help of another person, place the generator on an elevated platform such as a table or workbench. TO DRAIN THE FUEL TANK 1. Remove the fuel tank cap and fuel strainer. 2. Using a petrol hand pump, empty the fuel tank into an approved petrol container. Siphon the petrol by inserting the tip of the pump into the side of the pump guard. NOTE: DO NOT use an electric pump 3. Reinstall the fuel strainer and replace the fuel tank cap.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TO DRAIN THE CARBURETTOR 1. Loosen the right maintenance cover knobs, and remove the cover from the side panel. 2. Turn the Main Switch to the Start/ Run position. 3. Remove the battery. 4. Prepare an approved petrol storage container and position it directly under the carburettor drain screw to catch the fuel. 5. Loosen the drain screw. 6. Allow the fuel to drain completely into the container. 7. Retighten the drain screw securely. 8. Turn the Main switch to the Off position. 9. Reinstall the maintenance cover NOTE: Make sure to drain the carburettor before storing the generator for long periods of time. DRAINING/CHANGING THE OIL Change the oil more often if operating under heavy load or high ambient temperature. It is also necessary to drain the oil from the crankcase if it has become contaminated with water or dirt. Changing the oil when the engine is warm allows for complete drainage. Change the oil according to the recommended maintenance schedule on page 19. TO CHANGE THE ENGINE OIL: 1. With the help of another person, place the generator on an elevated platform such as a table or workbench. 2. Loosen the screws of the left hand side maintenance cover, and remove the cover from the side panel. 3. Place a suitable container underneath the generator to catch the used oil.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 4. Reach under the generator and remove the black rubber seal located below the oil drain plug. 5. Remove the oil fill cap/dipstick. 6. Remove the other black rubber seal located in the front of the oil drain plug. 7. Use a spanner to remove the oil drain plug and allow the oil to drain completely. 8. Reinstall the oil drain plug after the oil has drained. 9. Reinstall the 2 black rubber seals. NOTE: NEVER dispose of used engine oil in general rubbish or down a drain. See local authority recycling for more information. 10. With the generator in a level position, refill the the engine with new oil. See section Add/Check Oil on page 12. 11. Reinstall the oil dipstick and tighten it securely. Wipe clean any oil spillage and reinstall the oil access cover. 12. Replace the maintenance cover. TRANSPORTING THE GENERATOR To prevent fuel spillage when transporting, be sure to perform the following: 1. Tighten the fuel cap and turn the vacuum relief valve to ‘OFF’ 2. Set the engine switch to ‘OFF’. 3. Drain the fuel tank if possible, see section Draining the Fuel Tank/carburettor on pages 22-23. 4. Keep the generator upright. NEVER place the generator on its side or upside down - doing so will make it difficult to start next time. WARNING: AVOID DIRECT SUNLIGHT INSIDE A VEHICLE. IF THE GENERATOR IS LEFT IN AN ENCLOSED VEHICLE FOR MANY HOURS, THE HIGH TEMPERATURE COULD CAUSE THE FUEL TO VAPORISE AND RESULT IN A POSSIBLE EXPLOSION.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com STORING THE GENERATOR Shut off the generator and allow the unit to cool to room temperature before storing it. NEVER place any type of storage cover on the generator while it is still hot. DO NOT obstruct any ventilation openings. Follow the procedures below for properly storing your generator. We highly recommend running your generator once a month for 20 to 30 minutes. Plug in a small load to ensure there is proper power output. FOR SHORT PERIODS (30 TO 60 DAYS) NOTE: DO NOT store fuel for more than 2 months
- Drain the fuel tank and carburettor (see section Draining the Fuel Tank/ carburettor on pages 22-23).
- Disconnect the negative lead from the battery (see section Connecting the Battery on pages 14-15).
- Add fuel stabiliser. Follow the suggested portions and instructions for your preferred stabiliser. Run the engine for 15 to 20 minutes, allowing the fuel stabiliser to mix with the petrol and circulate through the carburettor, and then top off with fuel. Filling the fuel tank full reduces the amount of air in the tank and helps fight deterioration of the fuel. FOR EXTENDED PERIODS (OVER 60 DAYS)
- Disconnect the negative lead from the battery (see section Connecting the Battery on pages 14-15).
- Drain the fuel tank and carburettor (see section Draining the Fuel Tank/ carburettor on pages 22-23). NEVER store the generator with fuel in the tank for more than two months.
- Change the engine oil (see section Draining and Changing the Oil on pages 23- 24). FOR 1 YEAR OR MORE
- Remove the spark plug, put a tablespoon of engine oil into the spark plug cylinder. Turn the engine slowly using the pull rope to distribute the engine oil. Reinstall the spark plug.
- Drain the fuel tank and carburettor (see section Draining the Fuel Tank/ carburettor on pages 22-23).
- Change the engine oil.
- After removal from storage, fill with fresh petrol.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com NOTE: If storing petrol in a suitable container for later use, make sure the petrol has been treated with fuel stabilizer according to the stabilizer manufacturers instructions. ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility. If disposing of this product or any damaged components, do not dispose of with general waste. This product contains valuable raw materials. Metal products should be taken to your local civic amenity site for recycling of metal products. PRODUCT DISPOSAL DO NOT dispose of used generator or parts with your household waste. This product contains electrical or electronic components that should be recycled under the WEEE regulations. Please take this product to your local recycling facility for responsible disposal to minimise its environmental impact. DO NOT dispose of used oil or fuel in general waste or down a drain. Please see local authority recycling for more information. WARNING: STORE THE GENERATOR UPRIGHT IN A COOL AND DRY LOCATION, AWAY FROM SOURCES OF HEAT, OPEN FLAMES, SPARKS OR PILOT LIGHTS.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com MAINTENANCE RECORD ENGINE OIL (PAGE 23/24) AIR FILTER (PAGE 20) SPARK PLUG (PAGE 21) SPARK ARRESTER (PAGE 21/22) FUEL TANK & CARBURETTOR (PAGE 22/23) FUEL FILTER (PAGE 19)
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SPECIFICATIONS CLARKE part no 8877135 IG8000 Engine Engine Model SC460 Fuel Type Unleaded Petrol (E10) Displacement (cc) 459 (16HP) Start system Electric, Remote Control & Hand Recoil Fuel tank capacity (L) 26 Fuel consumption (L/Hr) 3.1 Maximum run time @75% Load 8 hours 15 mins Engine oil type SAE10W30 Engine oil capacity (L) 1 Litre Battery 12V, 14Ah Lead Acid High Temperature Shut Down 80°C Generator Rated Frequency (Hz) 50 AC Output Voltage (230V) 13A x 2, 32A x 1 DC Output Voltage (V) 5V x 1 (USB) & 12V x 1 Rated Running Power (W) 7000 Max. Starting Power (W) 7500 IP Rating IP23M Dimensions Depth x Width x Height (mm) 610 x 770 x 755 Weight (kg): Minus Fuel & Oil 114 Environmental Sound pressure level 74 dB Sound power level 94 dB Guaranteed sound power level 97 dB Uncertainty factor 2.8 dB
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The generator fails to start Battery not charged Charge battery Engine switch is in the OFF position Turn engine switch to the ON position No fuel Fill fuel tank (see pages 13-14) Stale petrol or water in petrol Drain entire system and refill with fresh fuel (see pages 22- 23) Engine oil level is low Engine is equipped with Low Oil Shutoff. If engine oil level is low, it must be filled before unit will start. Check engine oil level and fill if necessary (see pages 12- 13) Fuel switch is in the OFF position Turn fuel switch to the ON posi- tion Spark plug faulty, fouled, or improperly gapped Replace spark plug (see page 21) Engine stored without treating or draining petrol, or refueled with bad petrol Drain fuel. Refuel with fresh pet- rol (see pages 22-23) Dirty fuel filter Replace fuel filter or contact the CLARKE service department Engine lacks power Dirty air filter Check air filter element. Clean or replace as needed (see page 20) Engine stored without treating or draining petrol, or refueled with bad petrol Drain fuel. refuel with fresh pet- rol (see pages 22-23). If problem continues, contact the CLARKE service department
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com If this does not solve your problem contact the CLARKE service department. The generator is difficult to start The air filter is dirty. Clean the air filter (Page 20). AC receptacle does not work OUTPUT indicator is OFF, and OVERLOAD indicator is ON Check AC load (see pages 10- 11). Stop and restart the engine. Check the cooling air inlet. Stop and restart the engine. AC Circuit protector has tripped Check AC load and reset AC cir- cuit protectors (see pages 9-11) GFCI system has activated (if used) Reset the GFCI Item plugged in is defective Try a different device. PROBLEM POSSIBLE CAUSE SOLUTION
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com PARTS LISTS AND DIAGRAMS MACHINE CORE COMPONENTS
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ITEM DESCRIPTION QTY
1 Engine 1
2 Air Filter Holder 1
3 Temperature Sensor 1
4 Muffler Exhaust Lower Hood Assembly 1
5 Muffler Lower Cover Plate 1
6 Hexagon Flange Bolt 2
7 Motor Exhaust Hood 1
8 Hexagon Flange Bolt 1
9 Hexagon Flange Bolt 4
10 Muffler Assembly 1
11 Muffler Washer 2
12 Spring Washer 2
13 Flange Nut 2
14 Washer 4
15 Hexagon Flange Bolt 4
16 Muffler Exhaust Upper Hood Assembly 1
17 Hexagon Flange Bolt 6
18 Washer 6
19 Muffler Exhaust Hood 1
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com BASE PLATE COMPONENTS
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ITEM DESCRIPTION QTY
1 Support Plate 1
2 Hexagon Flange Bolt 1
3 Inverter Absorber Washer 2
4 Oil Plug 1
5 Shock Absorber 3
6 Flange Nut 4
7 Shock Absorber 1
8 Grounding Cable 1
9 Clamp Nut 16
10 Flange Nut 4
11 Axle 1
12 Wheel Assembly 4
13 Axle 1
14 Hexagon Flange Bolt 18
15 Washer 3
16 Bushings 1
17 Brake Components 1
18 Hexagon Flange Bolt 2
19 Battery Box 1
20 Battery 1
21 Battery Band 1
22 Negative Charging Cable 1
23 Positive Charging Cable 1
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com RACK COMPONENTS
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ITEM DESCRIPTION QTY
1 Bracket - Right 2
2 Bracket - Left 2
3 Flange Nut 16
4 DC Voltage Regulator 1
5 Hexagon Flange Bolt 1
6 Hexagon Flange Bolt 10
7 Right Frame Beam 2
8 Front/Back Upper Beam 2
9 Front Lower Beam 1
10 Control Panel Assembly 1
11 Hexagon Flange Bolt 4
12 Hood Assembly 1
13 Inverter Fixing Bracket - Left 1
14 Inverter Fixing Bracket - Right 1
16 Inverter Parts 1
17 Flange Nut 4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com OVERLAY COMPONENTS
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ITEM DESCRIPTION QTY
1 Fuel Tank Assembly 1
2 Fuel Tank Seal 1
3 Self Tapping Screw 12
4 Upper Cover Assembly 2
5 Hexagon Flange Bolt 8
6 Rubber Sleeve, Handle 1
7 Handle Assembly 1
8 Handle Assembly 1
9 Rubber Sleeve, Handle 1
10 Hexagon Flange Bolt 4
11 Filter Assembly 1
12 Fuel Pipe 1
13 Clamps 2
14 Clamps 1
15 Hexagon Flange Bolt 36
16 Left Window Plate Assembly 1
17 Left Panel Assembly 1
18 Right Panel Assembly 1
19 Oil Plug 1
20 Right Window Plate Assembly 1
21 Inverter Overlay Assembly 1
22 Motor Overlay Assembly 1
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com HANDLE COMPONENTS
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ITEM DESCRIPTION QTY
1 Nylon Nut 4
2 Hexagon Flange Bolt 4
3 Handle Fixing Pin 2
4 Flange Nut 2
5 Handle Assembly 1
6 Rubber Sleeve, Handle 2
7 Rubber Plug 2
8 Left Fixing Bracket, Handle 1
9 Right Fixing Bracket, Handle 1
10 Movable Pin 1
11 Fastening Spring 1
12 Handle Component 1
13 Hexagon Flange Bolt 1
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY - UKCA
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY - CE
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CLARKE GENERATOR ACCESSORIES 230V Blue Generator Plug - GP32/2 Extension Lead - EL14IEC 20 Litre Fuel Can Green - JC20LG
- 230V 32A Generator Plug
- Part No. 6160730
- Max. Capacity: 13A, 3120W
- 14 Metre Length
- Part No. 3220845
- 0.8mm Thick Steel Construction
- Locking Pin on Cap
- Part No. 7649900 Oil Drainage Pan - COP8 SAE30 Motor Oil - SAE30 Fuel Can Spout - SP20L
- 8 Litre Capacity.
- Wide Pan with Pouring Lip
- Part No. 7649850
- 1 Litre
- Part No. 3050852
- Bayonet type fitting with rubber seal
- Part No. 7650225