HSOS GREYSTONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM OUTSIDE HUMIDITY TRANSMITTER HSOS SERIES PRODUCT DESCRIPTION The outside humidity transmitter uses a highly accurate and reliable Thermoset Polymer based capacitance humidity sensor and state-of- the-art digital linearization and temperature compensated circuitry to monitor humidity levels. The sensor is encapsulated in a field replaceable sensor hub for protection from the elements. A weatherproof enclosure that provides ease of installation is provided. An optional integrated temperature sensor is available. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The outside transmitter should be mounted on an outside North facing wall, under the eaves which will provide protection from direct sunlight and wind. The outside transmitter can be mounted directly to buildings wall face using the provided mounting holes. There is a 0.86” hole for conduit connection of the back of the enclosure. SENSOR TYPE Thermoset polymer based capacitive SENSOR ACCURACY ±2, 3, or 5 %RH (5 to 95 %RH) MEASUREMENT RANGE 0 to 100 %RH RESOLUTION ±0.01 %RH HYSTERESIS ±0.8 %RH @ 25°C (77°F) RESPONSE TIME 8 seconds STABILITY <0.25% RH/year AMBIENT OPERATING RANGE -40 to 60°C (-40 to 140°F) POWER SUPPLY 24 Vac/dc ~ ±10% typical CONSUMPTION 22 mA maximum @24Vdc, 70mA @24Vac OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc, 0-10 Vdc, or 0-1 Vdc (field selectable) OUTPUT DRIVE @ 24 VDC Current: 550Ω max Voltage: 10,000Ω min OPTIONAL TEMPERATURE SENSOR Feed Through Sensor: Various RTD’s and thermistors available as 2 wire resistance output ENCLOSURE A: Polycarbonate, UL94-V0, IP65 (NEMA 4X) E: Same as A, with cable gland fitting TERMINATION Screw terminal block (14 to 22 AWG) COUNTRY OF ORIGIN Canada SPECIFICATIONS CABLE GLAND FITTING OPTIONAL ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION 82.5 mm 3.25” 69.8 mm 2.75” 52.0 mm 2.05” 76.2 mm 3.00” 25.4 mm 1.00” 25.4 mm 1.00” 0.5” NPT North OSA Temperature Sensor

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-HSOSXXX-06 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com WIRING INFORMATION TERMINAL FUNCTION PWR 24 Vac/dc of controller or power supply COM GND or COMMON OUT Analog Output TS1 Resistance Output TS2 Resistance Output PRODUCT HSOS Outside Humidity Transmitter ENCLOSURE A E Polycarbonate with hinged and gasketed cover Same as A, with cable gland fitting RH ACCURACY 2 OPTIONAL TEMPERATURE SENSOR 00 No Temperature Sensor Option 100Ω Platinum, IEC 751, 385 Alpha, thin film, 3 wire 1801Ω NTC Thermistor, ±0.2°C 3000Ω NTC Thermistor, ±0.2°C 10,000Ω Type 3, NTC Thermistor, ±0.2°C 2.252KΩ NTC Thermistor, ±0.2°C 1000Ω Platinum, IEC 751, 385 Alpha, thin film 1000Ω Nickel, Class B, DIN 43760 10,000Ω Type 3, NTC Thermistor, ±0.2°C c/w 11K shunt resistor 20,000Ω NTC Thermistor, ±0.2°C 10,000Ω Type 2, NTC Thermistor, ±0.2°C ORDERING HSOS PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. PRODUCT HRMOS Replacement Humidity Sensor Module - Hub RH ACCURACY 2 OPTIONAL TEMPERATURE SENSOR 00 No Temperature Sensor Option 100Ω Platinum, IEC 751, 385 Alpha, thin film, 3 wire 1801Ω NTC Thermistor, ±0.2°C 3000Ω NTC Thermistor, ±0.2°C 10,000Ω Type 3, NTC Thermistor, ±0.2°C 2.252KΩ NTC Thermistor, ±0.2°C 1000Ω Platinum, IEC 751, 385 Alpha, thin film 1000Ω Nickel, Class B, DIN 43760 10,000Ω Type 3, NTC Thermistor, ±0.2°C c/w 11K shunt resistor 20,000Ω NTC Thermistor, ±0.2°C 10,000Ω Type 2, NTC Thermistor, ±0.2°C ORDERING - REPLACEMENT SENSOR MODULE HRMOS PART NUMBER OUT COM PWRTS1 TS2 mA VOLT 10V 1V 5V