HR330 SEOUL | Alldatasheet
Document overview
- Manufacturer or author: pROVIDED bY alldatasheet.com(free datasheet download site)
- PDF pages: 9
Technical content
Features
- High flux output and high luminance
- Designed for high current operation
- Uniform color
- Low profile and low thermal resistance
- Packaged in tubes for use with automatic insertion equipment Application
- Automotive exterior lighting
- Electronic signs and signals
- Channel letter / lighting
- Decorative lighting
- Specialty Lighting
-2- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Outline Dimensions Unit : mm 0.5 1.4 7.62 ± 0.5 ANODE 3 ± 0.2 CATHODE CHAMFER 1.25 X 1.25 7.5 ± 0.5 4.4 1.5±0.2 0.76 ± 0.1 5.08 ± 0.2 7.62 ± 0.5 5.0° 2.5 ± 0.5 0.4 ± 0.2 5.08 ± 0.3
1.4 MAX
Notes : Protruded epoxy is 1.4mm maximum.
-3- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Electro-Optical Characteristics ( Ta = 25ºC, IF=70mA ) 635625 nm615λdDominant Wavelength[3] lm/W-30-ŋoptOptical Efficiency V3.42.5-VFForward Voltage[4] 90 deg.2θ½View Angle -6.04.4 µA-IRReverse Current (at VR = 5V) Max.Typ.Min. lmФV [2]Luminous Flux [1] Unit Value SymbolItem Absolute Maximum Ratings ( Ta = 25ºC ) mW210PDPower Dissipation V5VRReverse Voltage ºC260ºC for 5second [6]TSSolder Temperature ºC-40 ~ 100ToprOperating Temperature mA100IFP [5]Forward Peak Pulse Current ºC-50 ~ 105TstgStorage Temperature mA70IFDC Forward Current UnitValueSymbolItem Notes : [1] SSC maintains a tolerance of ±10% on flux and power measurements. [2] ФV is the total luminous flux output as measured with an integrated sphere. [3] Dominant wavelength is derived from the CIE 1931 Chromaticity diagram. A tolerance of ±0.5nm for dominant wavelength [4] A tolerance of ±0.05V on forward voltage measurements [6] No closer than 1.5mm from the base of the stopper.
-4- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Characteristic Diagrams 1.6 2.0 2.4 2.8 100 Forward Current(mA) Forward Voltage [V] Ta= 25ºC 0 204 0 608 0 100 0.0 0.4 0.8 1.2 1.6 Relative Luminous Flux Forward Current [mA] Ta= 25ºC Forward Voltage vs. Forward Current Forward Current vs. Relative Flux -40 -20 0 204 06 0 80 100 100 Forward Current IF [mA] Ambient Temperature TA [ O Ta= 25ºC -90 -60 -30 0 30 60 90 0.0 0.2 0.4 0.6 0.8 1.0 Relative Luminous Intensity Off Axis Angle [deg.] Ta= 25ºC, IF= 70mA Ambient Temperature vs. Forward Current Directivity
-5- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Bin Code Description 41J Forward VoltageDominant WavelengthLuminous Flux Bin Code Available ranks 6356252 6256151 Max.Min.Bin Code Dominant Wavelength (nm) @ IF = 70mA 2.01.81 2.22.02 2.42.23 2.62.44 2.82.65 3.02.86 3.23.07 3.43.28 3.63.49 Max.Min.Bin Code Forward Voltage (V) @ IF = 70mA 13.010.0L 10.07.6K 7.65.8J 5.84.4H 4.43.4G 3.42.6F 2.62.0E 0.70.5A 1.41.0C 2.01.4D 1.00.7B Max.Min.Bin Code Luminous Flux (lm) @ IF = 70mA
-6- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Packing 485±1 21600pcs/box (12packs/box) * Aluminum Sealing pack (in silica gel)1800pcs max/pack (30tubes max/pack) 3.2 5.1 9.72 0.6 2.6 5.8 SEOUL SEMICONDUCTOR CO., LTD. HXXXX 60pcs BINOOO (21600pcs max/box) (12packs max/box) Unit : mm * Cardboard box (500x220x280) * Plastic tube 60pcs max/tube HXXXX RANK : XXXX QTY : 1800pcs LOT : 20XX.XX.XX SEOUL SEMICONDUCTOR CO., LTD
-7- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Soldering Profile 1) Wave Soldering Conditions / Profile
- Preliminary heating to be at 85ºC(120 ºC max) for 20 seconds(60 seconds max).
- Soldering heat to be at 235 ºC (240ºC max) for 4 seconds (5 seconds max.)
- Soak time above 200 ºC is 5 seconds 2) Hand Soldering conditions
- Not more than 3 seconds at max. 350ºC, under Soldering iron. 3) Caution
- Leadframes are silver plated copper alloy. This substance has a low thermal coefficient (easily conducts heat)
- No closer than 1.5mm from the base of the stopper.
- The LEDs must not be repositioned after soldering.
- Do not apply any stress to the lead particularly when heat. 0 2 4 6 8 10 1 2 1 4 16 18 2 0 22 24 26 2 8 30 3 2 34 36 10 0 15 0 20 0 25 0 Temperature [ O Ti m e [s ] PREHEAT 20s (60s Max) 85 ºC(120 ºC max) PEAK 4s (5s max) 235 ºC (240 ºC max) Note : In case the soldered products are reused in soldering process, we don’t guarantee the products.
-8- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) Precaution for Use 1) Storage
- Before opening the package Avoid the absorption of moisture, we recommended to store High Flux LEDs in a dry box(or desiccator) with a desiccant . Otherwise, store them in the following environment: Temperature : 5℃~30℃ Humidity : 50% max.
- After opening the package a. Soldering should be done right after opening the package(within 24Hrs). b. Keeping of a fraction - Sealing - Temperature : 5 ~ 40℃, Humidity : less than 30% c. If the package has been opened more than 1week or the color of desiccant changes, Components should be dried for 10-12hr at 60±5℃
- Any mechanical force or any excess vibration shall not be accepted to apply during cooling process to normal temp. after soldering.
- Avoid quick cooling
- Leadframes are silver plated copper alloy. The silver plate surface may be affected by environments which contains corrosive substances. Please avoid conditions which may cause the LEDs to corrode, tarnish or discolor. 2) Static Electricity
- Static Electricity and surge voltage damage the LEDs. So it is recommended that a wrist band or an anti-electrostatic glove be used when handling the LEDs.
- All devices, equipment and machinery must be properly grounded. It is recommended precautions be taken against surge voltage to the equipment that mounts the LEDs. 3) Heat Generation
- Thermal is one of the important parameter to design the end product. Please consider the heat generation of the LEDs.
- The operating current should be decided after considering the ambient maximum temperature of LEDs.
-9- RED HIGH FLUX LED HR330 <070803> Rev.1.5 서식번호 : QP-7-03-05 (Rev.00) 4) Others
- The color of the LEDs is changed a little by an operating current and thermal.
- Anti radioactive ray design is not considered for the products listed here in.
- Gallium arsenide is used in some of the products listed in this publication. These products are dangerous if they are burned or smashed in the process of disposal. It is also dangerous to drink the liquid or inhale the gas generated by such products when chemically disposed.
- This device should not be used in any type of fluid such as water, oil, organic solvent and etc. When washing is required, IPA(Isopropyl Alcohol) should be used.
- When the LEDs are illuminating, operating current should be decided after considering the junction temperature. Cf.) Please refer Ambient temperature vs. Forward Current graph on page 5
- The appearance and specifications of the product may be modified for improvement without notice. SEOUL SEMICONDUCTOR CO., LTD. 148-29, Kasan-Dong, Keumchun-Gu, Seoul, Korea TEL : +82-2-3281-6269 FAX :+82-2-858-5537 Homepage : www.seoulsemicon.com www.zled.com E-Store : www.zledstore.com E-mail : sscsale@seoulsemicon.com