HR310 SEOUL | Alldatasheet

Document overview

  • Manufacturer or author: pROVIDED bY alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Features

  • High flux output and high luminance
  • Designed for high current operation
  • Uniform color
  • Low profile and low thermal resistance
  • Packaged in tubes for use with automatic insertion equipment Application
  • Automotive exterior lighting
  • Electronic signs and signals
  • Channel letter / lighting
  • Decorative lighting
  • Specialty Lighting

-2- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Outline Dimensions Unit : mm 7.62 ± 0.5

1.4 MAX

4.4 7.5 ± 0.2 2.5 ± 0.1 5.0° 5.08 ± 0.3 0.4 ± 0.2 5.08 ± 0.2 0.76 ± 0.1 1.5±0.2 0.5 7.62 ± 0.5 1.9 3 ± 0.2 ANODE CHAMFER 1.25 X 1.25 CATHODE Notes : Protruded epoxy is 1.4mm maximum.

-3- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Electro-Optical Characteristics ( Ta = 25ºC, IF=70mA ) 630625 nm615λdDominant Wavelength[3] lm/W-33-ŋoptOptical Efficiency V3.02.6-VFForward Voltage[4] ºC /W120RθJ-PThermal Resistance mcd-10000-IVLuminous Intensity 40 deg.2θ½View Angle -6.04.4 µA-IRReverse Current (at VR = 5V) Max.Typ.Min. lmФV [2]Luminous Flux [1] Unit Value SymbolItem Absolute Maximum Ratings ( Ta = 25ºC ) mW224PDPower Dissipation V5VRReverse Voltage ºC260ºC for 5second [6]TSSolder Temperature ºC-40 ~ 100ToprOperating Temperature mA100IFP [5]Forward Peak Pulse Current ºC-50 ~ 105TstgStorage Temperature mA70IFDC Forward Current UnitValueSymbolItem Notes : [1] SSC maintains a tolerance of ±10% on flux and power measurements. [2] ФV is the total luminous flux output as measured with an integrated sphere. [3] Dominant wavelength is derived from the CIE 1931 Chromaticity diagram. A tolerance of ±0.5nm for dominant wavelength [4] A tolerance of ±0.05V on forward voltage measurements [6] No closer than 1.5mm from the base of the stopper.

-4- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Reliability Tests 0/221 time1kV, 1.5kΩ ; 100pFESD (Human Body Model) cycles Ta = -50ºC (30min) ~ 105º (30min) (Transfer time : 5sec, 1Cycle = 1hr)Thermal Shock 0/22500hrsTa = 85ºC, RH = 85%, IF = 40mATemperature Humidity Operating 0/221000hrsTa = 85ºC, RH = 85%Temperature Humidity Storage 0/221000hrsTa = -50ºCLow Temperature Storage 0/221000hrsTa = 105ºCHigh Temperature Storage Failures 1 timeTs = 255 ± 5ºC, t = 4 ± 1secResistance to soldering Heat 1000hrsTa = 100ºC, IF = 20mAHigh Temperature Operating 1000hrsTa = -40ºC, IF = 70mALow Temperature Operating 1000hrsTa = RT, IF = 70mALife Test NoteConditionItem < Judging Criteria For Reliability Tests > LSL [2] X 0.7ФV USL X 2.0IR USL[1] X 1.2VF Notes : [1] USL : Upper Standard Level [2] LSL : Lower Standard Level.

-5- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Characteristic Diagrams 0 102 03 0 405 06 07 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Rth(J-A) = 200 o C/W Rth(J-A) = 300 o C/W Rth(J-A) = 400 o C/W Rth(J-A) = 500 o C/W Relative Luminous Flux Forward Current [mA] Ta= 25ºC Ta= 25ºC Forward Current(mA) Forward Voltage [V] Forward Voltage vs. Forward Current Forward Current vs. Relative Flux 0 20 40 60 80 100 616 618 620 622 624 626 Dominant Wavelength [nm] Forward Current [mA] Ta= 25ºC -40 -20 0 20 40 60 80 100 120 Rth(J-A) : 500 O C/W Rth(J-A) : 400 O C/W Forward Current IF [mA] Ambient Temperature TA [ O Rth(J-A) : 300 O C/W Ambient Temperature vs. Maximum Forward Current Forward Current vs. Dominant Wavelength

-6- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) IF= 70mA 0 204 0 608 0 100 2.5 2.6 2.7 2.8 2.9 Forward Voltage [V] Ambient Temperature Ta[ o IF= 70mA 0 204 0 608 0 100 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Relative Luminousity Flux Ambient Temperature Ta[ o Ambient Temperature vs. Forward Voltage Ambient Temperature vs. Relative Flux 400 500 600 700 0.0 0.5 1.0 Relative Emission Intensity Wavelength [nm] Ta= 25ºC, IF= 70mATa= 25ºC, IF= 70mA -90 -60 -30 0 30 60 90 0.0 0.2 0.4 0.6 0.8 1.0 Relative Luminous Intensity Off Axis Angle [deg.] Spectrum Directivity

-7- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Bin Code Description 62J Forward VoltageDominant WavelengthLuminous Flux Bin Code Available ranks 13.010.0L 10.07.6K 7.65.8J 5.84.4H 4.43.4G 3.42.6F 2.62.0E 0.70.5A 1.41.0C 2.01.4D 1.00.7B Max.Min.Bin Code Luminous Flux (lm) @ IF = 70mA 6206150 6256201 6306252 Max.Min.Bin Code Dominant Wavelength (nm) @ IF = 70mA 2.852.705 2.352.201 2.502.352 2.602.503 2.702.604 3.002.856 Max.Min.Bin Code Forward Voltage (V) @ IF = 70mA

-8- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Packing (Tube) 485±1 SEOUL SEMICONDUCTOR CO., LTD. made in Korea Unit : mm * Plastic tube 60pcs max/tube DEVICE HR310 J14 LOT NO. 20XX.XX.XX CAT J14 QTY 60 D/C 07XX 9.7 0.6 5.8 2.6 5.1 2.5 Top view Side view AnodeCathode

-9- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) * Aluminum Sealing pack (in silica gel) 1200pcs max/pack (20tubes max/pack) (21600pcs max/box) (18packs max/box) Unit : mm * Cardboard box (500x220x280) HXXXX RANK : XXXX QTY : 1200pcs LOT : 20XX.XX.XX SEOUL SEMICONDUCTOR CO., LTD Packing (Sealing pack & Box)

-10- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Soldering Profile 1) Recommended Wave Soldering Conditions / Profile

  • Preliminary heating to be at 85ºC(120 ºC max) for 20 seconds(60 seconds max).
  • Soldering heat to be at 255 ºC (260ºC max) for 4 seconds (5 seconds max.)
  • Soak time above 200 ºC is 5 seconds 2) Hand Soldering conditions
  • Not more than 3 seconds at max. 350ºC, under Soldering iron. 3) Caution
  • Leadframes are silver plated copper alloy. This substance has a low thermal coefficient (easily conducts heat)
  • No closer than 1.5mm from the base of the stopper.
  • The LEDs must not be repositioned after soldering.
  • Do not apply any stress to the lead particularly when heat. 0 2 4 6 8 10 1 2 1 4 16 18 2 0 22 24 26 2 8 30 3 2 34 36 10 0 15 0 20 0 25 0 30 0 Temperature [ O Ti m e [s ] PREHEAT 20s (60s Max) 85 ºC(120 ºC max) PEAK 4s (5s max) 255 ºC (260 ºC max) Note : In case the soldered products are reused in soldering process, we don’t guarantee the products.

-11- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) Precaution for Use 1) Storage

  • Before opening the package a. Avoid the absorption of moisture, we recommended to store High Flux LEDs in a dry box(or desiccator) with a desiccant . Otherwise, store them in the following environment: Temperature : 5℃~30℃ Humidity : 50% max. b. The products should be used in 3 months. It is recommended that the LEDs be used as soon as possible.
  • After opening the package a. Soldering should be done right after opening the package(within 24Hrs). b. Keeping of a fraction - Sealing - Temperature : 5 ~ 40℃, Humidity : less than 30% c. If the package has been opened more than 1week or the color of desiccant changes, components should be dried for 10-12hr at 60±5℃
  • Any mechanical force or any excess vibration shall not be accepted to apply during cooling process to normal temp. after soldering.
  • Avoid quick cooling
  • Leadframes are silver plated copper alloy. The silver plate surface may be affected by environments which contains corrosive substances. Please avoid conditions which may cause the LEDs to corrode, tarnish or discolor. 2) Static Electricity
  • Static Electricity and surge voltage damage the LEDs. So it is recommended that a wrist band or an anti-electrostatic glove be used when handling the LEDs.
  • All devices, equipment and machinery must be grounded properly. It is recommended that precautions should be taken against surge voltage to the equipment that mounts the LEDs.

-12- RED HIGH FLUX LED HR310 <070523> Rev. 1.5 서식번호 : QP-7-03-05 (Rev.00) 3) Heat Generation

  • Thermal is one of the important parameters to design the end product. Please consider the heat generation of the LEDs.
  • The operating current should be decided after considering the ambient maximum temperature of LEDs. 4) Others
  • The color of the LEDs is changed slightly an operating current and thermal.
  • Anti radioactive ray design is not considered for the products listed here.
  • Gallium arsenide is used in some of the products listed in this publication. These products are dangerous if they are burned or smashed in the process of disposal. It is also dangerous to drink the liquid or inhale the gas generated by such products when chemically disposed.
  • This device should not be used in any type of fluid such as water, oil, organic solvent and etc. When washing is required, IPA(Isopropyl Alcohol) should be used.
  • When the LEDs are illuminating, operating current should be decided after considering the junction temperature. Cf.) Please refer Ambient temperature vs. Forward Current graph on page 5
  • The appearance and specifications of the product may be modified for improvement without notice. SEOUL SEMICONDUCTOR CO., LTD. 148-29, Kasan-Dong, Keumchun-Gu, Seoul, Korea TEL : +82-2-3281-6269 FAX :+82-2-858-5537 Homepage : www.seoulsemicon.com www.zled.com E-Store : www.zledstore.com E-mail : sscsale@seoulsemicon.com