HDR100-110J HITRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
/square6 100W Metal Box Format /square6 16.6-160VDC 10:1 Wide Input Range /square6 Design to Meet EN50155 Railway Standard /square6 Wide Operating Temperature Range of /square6 Free Air Convection /square6 Using 125 °° °°C Long Life Solid Capacitors /square6 CE Marking Level 3 Compliance Specification Input General Input Voltage 16.6-160VDC, nominal 110VDC Efficiency Typical 86.6% at 16.6VDC Input Current (F-L) 4.65A at 24VDC/1.0A at 110VDC Typical 90.5% at 48 VDC (no-laod) 0.08A at 24VDC/0.03A at 110VDC Typical 90.6% at 110 VDC Soft Star Installed Switching Frequency 110KHz at nominal I/P 110VDC Inrush Current Peak 27A at nominal 110VDC Dielectric Withstand I/P-O/P: 3000VAC Input Connector V-H or M-T MA412-500M2B I/P-GND:1500VAC Output O/P-GND:1000VAC Output Connector M-T MA412-500M2B Circuit Topology Resonant ZVS & Fix-Flyback circuit Line Regulation Typical 0.2% Transient Response Peak transient < 300mV & recovers Load Regulation Typical ±1% within 3mS for 25% load-change Total Regulation Typical ±2% Power Density 3.75Watts/Cubic Inch Noise & Ripple Typical 1% Peak-Peak Environmental Adjustability Factory Set Operating Temperature -40 °C to +85 °C with de-rating Output Trim Available Storage Temperature -45°C to +90°C Protection Cooling Convection-cooled Over Voltage Built-in Safety/EMC Over Current Installed Emissions (conducted) CISPR EN55022 Class B Over Load Typical 130% maximum load Safety Standard IEC60950-1 Class I fully protected against output CE Standard Meet Level 3 Criteria A overload or short circuit Vibration Six degree-of-freedom random Over Temperature Thermostat 10Hz-150Hz, 10G Input-Under & Installed Radiated Susceptibility EN61000-4-3 Level X (20V/m) Over-Voltage Surge EN61000-4-5 Level 3 , L-L 2KV,L-G 2KV Input Reverse Voltage Installed Conducted Disturbance EN61000-4-6 Level X (20V/m) Conformal Coating Available Notes: (1) All measurement are at nominal input, full load and +25°C unless otherwise specifications. (2) Due to requests in market and advances in technology, specifications subject to change without notification. (3) A warm-up time 10 minutes is required after cold start at temperature from -40°C to +0°C. (4) 125°C OS-CON Long-life Solid capacitors are installed in secondary circuits.
Version A edited on July 22, 2016 -2- Output voltage & current rating chart Single Output Model No. V1 /uni2605 Min. Typ. Volt. Max. Peak HDR100-110J-120830 0A 8.3A 12V 8.3A 10.00A HDR100-110J-240420 0A 4.2A 24V 4.2A 5.50A HDR100-110J-480210 0A 2.1A 48V 2.1A 2.75A HDR100-110J-530190 0A 1.9A 53V 1.9A 2.30A Symbol: /uni2605 “OVP” built-in Notes: Maximum o/p power 100W for convection cooling. Mechanical Dimensions (All dimensions are in mm[inch]) Derating Chart Immunity to environmental conditions Standard Condition EN5015512.2.1 & 12.2.6 EN5015512.2.4 I/P:16.6-110VDC O/P:100W(Fanless) Pass Class S2 & Class C2 Pass Class TX & Column 3 Pin assignment Assignment I+ I- GND V1 DC COM Pin # CNT1-I+ CNT1-I- GND CNT2-VO1 CNT2-COM