HVP100 HITRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

-43- H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP100 SERIES FEATURES: „ ACCOMMODATE UNIVERSAL AC SOURCES „ MEET IEC 61000-3-2 HARMONIC CORRECTION „ MEET UNIVERSAL SAFETY STANDARDS „ EMI MEET CISPR PUB. 22 CLASS B „ CE MARKING COMPLIANCE For the details of safety approval, please consult the factory. OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: B-S connector. Output Wattage: Typ. 100 Watts. Line Regulation: Typ. 1.0%. Load Regulation: Main VO1 typ. ±1.0%. Noise & Ripple: Typ. 1.0% peak to peak. OVP: Built-in at main VO1 only. Remote Sense: Installed in VO1. Adjustability: Available at main O/P VO1. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: B-S connector. Input Frequency: 47-63Hz. Inrush Current: Typ. 20A @230Vac (active). Input Current: 1.6A@115Vac, 0.6A@230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR PUB. 22 Class B. Hold-up Time: Typ. 30mS @ 115Vac & 230Vac. Power Fail Signal: Installed. Power Factor Correction: Meet Harmonic Correction per IEC 61000-3-2.PF typ. 0.98. Earth Leakage: Less than 0.5mA. GENERAL SPECIFICATION Efficiency: Typ. 74-79%. Switching Frequency: Fixed frequency at 85 or 80K Hz. Circuit Topology: PWM fixed frequency forward circuit. Transient Response: Output voltage returns in l e s s t h a n 3 m S f o l l o w i n g a 2 5 % l o a d c h a n g e . Safety Standard: UL 60950-1/EN 60950-1 Class I. Operating Temperature: 0 to +50°C. Storage Temperature: -20 to +85°C. Temperature Coefficient: Typ. 0.04% /°C. Cooling: Free air convection. Recommended 20cfm fan cooling for full load. Construction: Enclosure box or L-bracket format. Power Density: 2.16Watts / Cubic Inch. Note: Due to requests in market and advances in technology, specifications subject to change without notification.

-44- OUTPUT VOLTAGE / CURRENT RATINGS CHART MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: L-B 706.0g (24.9 Oz.) Box 795.0g (28.0 Oz.) SINGLE OUTPUT MAIN VO1 @# MODEL NO. Typ. Volt. HVP100-10 20.0A 5.0V HVP100-11 8.5A 12.0V HVP100-12 7.0A 15.0V HVP100-13 4.5A 24.0V HVP100-14 4.0A 28.0V HVP100-15 3.0A 36.0V HVP100-17 2.1A 48.0V HVP100-19 25.0A 3.3V TRIPLE OUTPUT HVP100- 30 12.0A +5.0V 3.0A +12V 0.8A 12V HVP100- 31 12.0A +5.0V 3.0A +12V 0.8A 5V HVP100- 32 12.0A +5.0V 1.5A +24V 0.8A 12V HVP100- 33 12.0A +5.0V 3.0A +15V 0.3A 15V HVP100- 392 12.0A +3.3V 3.0A +12V 0.8A 12V HVP100- 393 12.0A +3.3V 3.0A +15V 0.3A 15V HVP100- 394 12.0A +3.3V 1.5A +24V 0.8A 12V Symbol: "" OVP built-in. "@" Adjustable . "±" Positive or Negative se lectable (factory set). " #" Remote sensing. DUAL OUTPUT HVP100- 21 10.0A +5.0V 4.0A +12V HVP100- 22 10.0A +5.0V 3.2A +15V HVP100- 23 10.0A +5.0V 2.0A +24V HVP100- 291 15.0A +3.3V 4.0A +12V HVP100- 292 15.0A +3.3V 3.2A +15V HVP100- 293 15.0A +3.3V 2.0A +24V INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT SINGLE OUTPUT DUAL OUTPUT TRIPLE OUTPUT ASSORTED SIGNALS ASSIGNMENT AC-L AC-N AC-G VO1 DC-COM VO1 VO2 DC-COM VO1 VO2 VO3 DC-COM -SENSING +SENSING P.F DC-COM CNTR & PIN # P1-1 P1-2 P1-3 P1-4,5 P1-6.7 P1-4 P1-6 P1-5 P1-4 P1-6 P1-7 P1-5 P2-4 P2-3 P2-2 P2-1 Mating connector: P1: Non, Screw on Top. P2: Molex 5051 or equivalent.