Technical content

As of July, 2008 ET-080804 Under development New product GH04125A2A Blue violet Laser Diode High Power Blue violet Laser Diode ʢUnitɿmmʣ■ Outline Dimensions ■ Features (1) Wavelength : 406 nm(Typ.) (2) Optical power output : CW 125mW (3) Ї5.6mm CAN package [ Terminal connection ] П.*/ Пʶ П."9 П ʶ .*/ SFGFSFODFQMBOF ʶ ʶ ."9 ʶ ʶ ᶃ ᶅᶄ П."9 $."9 .*/ Пʶ ʶ ʶП ʶ ᶃ ᶄ ᶅ FNJTTJPOQPJOU ■ Applications (1) 406nm band light source (2) Laser sensor (3) other application ■ Absolute Maximum Ratings (Tc=25ˆ˞1) Parameter Symbol Ratings unit ˞ Optical power output(CW) Po 150 mW Reverse voltage Laser Vrl 2V Photo diode Vrd 30 V Operatings temperature(case temp.) Topc(c) -10ʙ+70 ˆ Storage temperature Tstg -40ʙ+85 ˆ ˞ Soldering temperature Tsld 350 ˆ ˞1 Tc : Case temperature ˞2 CW :Continuous Wave Operation ˞ Soldering position is 1.6mm apart from bottom edge of the case. (Immersion time: 3s) 4UFN ᶅ 1IPUPEJPEF -BTFSEJPEF ᶃ ᶄ ʢNoticeʣ ŋIn the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. ŋSpecifications are subject to change without notice for improvement.

As of July, 2008 ET-080804 ■ Specifications ˆ˞˞ Parameter Symbol MIN. TYP. MAX. unit Threshold current Ith - 35 50 mA Operating current Iop - 125 155 mA Operating voltage Vop - 5.4 6.4 V Wavelength λp 400 406 413 nm Half intensity angle Parallel θ∥ Po=125mW 6 9.5 12 ° ˞3 ˞4 Perpendicular θ˵ 16 19 24.5 ° Misalignment angle Parallel ∆θ∥ -2.5 - 2.5 ° ˞4 Perpendicular ∆θ˵ -3.0 - 3.0 ° ηd0 .9 1.3 - mW/mA Im 0.1 0.3 0.5 mA ˞ Tc : Case temperature ˞ Initial value, Continuous Wave Operation. Initial value is measured by the standard Laser tester of the sharp possession. ˞ Angle of 50% peak intensity.(Full angle at half-maximum) ˞ Paralel to the junction plane.(X-Z plane) Perpendicular to the junction plane.(Y-Z plane) Conditions Differential efficiency 115mW I(125mW)-I(10mW) Monitor Photo diode current Po=125mW, Vrd=5V ʢNoticeʣ ŋIn the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. ŋSpecifications are subject to change without notice for improvement.

As of July, 2008 ET-080804 ■ Optical power output – Forward current ■ Forward voltage – Forward current 0 50 100 150 200 250 Forward current IF (mA) Forward voltage VF (V) Condition CW -10 ˆ 0 ˆ 25 ˆ 50 ˆ 70 ˆ 100 150 0 50 100 150 200 250 Forward current IF (mA) Optical power output Po (mW) Condition CW -10 ˆ 0 ˆ 25 ˆ 50 ˆ 70 ˆ ■ Case temperature dependence of threshold current(Ith) ■ Case temperature dependence of operating current(Iop) 0.0 0.5 1.0 1.5 2.0 -20 0 20 40 60 80 Case temperature Tc (ˆ) Relative threshold current 0.0 0.5 1.0 1.5 2.0 -20 0 20 40 60 80 Case temperature Tc (ˆ) Relative operating current Po=125mW(CW) The value of Tc=25ˆis 1.0The value of Tc=25ˆis 1.0 Note) Characteristics shown in diagrams are typical values.(not assurance value) ■ Case temperature dependence of operating voltage(Vop)■ Case temperature dependence of monitor PD current(Im) 0.50 0.75 1.00 1.25 1.50 20 30 40 50 60 70 80 Case Temperature Tc (ˆ) Relative monitor PD current 0.0 0.5 1.0 1.5 2.0 -20 0 20 40 60 80 Case temperature Tc (ˆ) Relative operating voltage Po=125mW(CW) Po=125mW(CW) The value of Tc=25ˆis 1.0 The value of Tc=25ˆis 1.0

As of July, 2008 ET-080804 ■ Optical power dependence of Lasing spectrum■ Case temperature dependence of wavelength 402 403 404 405 406 407 408 Wavelength λp (nm) Relative optical power output 125mW 50mW 10mW 1mW Tc=25ˆ 400 402 404 406 408 410 412 414 416 20 30 40 50 60 70 80 Case Temperature Tc (ˆ) Wavelength λp (nm) Po=125mW(CW) ■ Far field pattern (FFP) (Tc=25ˆ, Po=125mW) -40 -30 -20 -10 0 10 20 30 40 Angle θ(°) Relative optical power output θ// Note) Characteristics shown in diagrams are typical values.(not assurance value)

As of July, 2008 ET-080804 ■C AUTION 1. These technical sheets include materials protected under the copyright of Sharp Corporation ("Sharp"). Please do not reproduce or cause anyone to reproduce them without Sharp's consent. 2. When using this product, please observe the absolute maximum ratings and the instructions for use outlined in these technical sheets, as well as the precautions mentioned below. Sharp assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these technical sheets, and the precautions mentioned below. (Precautions) (1) This products is designed for use in the following application areas; * OA equipment * Audio visual equipment * Home appliance * Telecommunication equipment (Terminal) * Measuring equipment * Tooling machines * Computers If the use of the product in the above application areas is for equipment listed in paragraphs (2) or (3), please be sure to observe the precautions given in those respective paragraphs. (2) Appropriate measures, such as fail-safe design and redundant design considering the safety design of the overall system and equipment, should be taken to ensure reliability and safety when this product is used for equipment which demands high reliability and safety in function and precision, such as ; * Transportation control and safety equipment (aircraft, train, automobile etc.) * Traffic signals * Gas leakage sensor breakers * Rescue and security equipment * Other safety equipment (3) Please do not use this product for equipment which require extremely high reliability and safety in function and precision, such as ; * Space equipment * Telecommunication equipment (for trunk lines) * Nuclear power control equipment * Medical equipment (4) Please contact and consult with a Sharp sales representative if there are any questions regarding interpretation of the above three paragraphs. 3. Please contact and consult with a Sharp sales representative for any questions about this product. ʢNoticeʣ ŋIn the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. ŋSpecifications are subject to change without notice for improvement.