GC118R GPSEMI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

GC118…R BAR CLAMP FOR HOCKEY PUK DEVICES Clamping total thikness of assembly from 3mm to 116mm Pre-loaded to the specific clamping force (22 ÷ 32 kN) Maximum device diameter: 105mm Surface passivation to provide extra protection Hexagon head bolt partially threaded M8x1.25, UNI5737, 8.8 steel Various lengths of bolts and insulators Round shaped clamping head for optimal clamping force application Four styles available User friendly clamping force indicator UL94 certified insulation material Types Notes Min Typ Max GC118S…R 930 1030 GC118B…R 1750 1870 GC118…22R 22 GC118…24R 24 GC118…30R 30 GC118…32R 32 Clamping Force tolerance ± 10% Insulation Voltage V RMS 1 min 3000 Noryl  ∗∗ UL File E322462 Max. working temperature °C -30 110 Creepage distance: mm 28 Clearance distance: mm 30.3 Storage temperature °C -40 110 mm UL94 V-1 Flame class rating 1.5 mm UL94 V-0 Flame class rating 8.00 mm CSA Flammability 1.00 * Other clamping forces available: contact factory ** Noryl  is a registered trade mark of General Electric Document GC118…RT001 Flammability Unit Testing conditions Values Weight g Clamping Force* kN Parameter Insulating Material Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it

BAR CLAMP FOR HOCKEY PUK DEVICES GC118…R ORDERING INFORMATION TABLE Clamps can be ordered using the following part numbering system GC118 B N B A 24 R S (1) Construction type: (2) Insulator position: (3) Insulator code: (4) Bolt code: (5) Clamping force (in kN): (6) Special accessories K: Total thickness of the assembly to be clamped For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories) Type GC118BN…R: suggested insulator/bolt types S' Min [mm] S Min [mm] S Max [mm] (3) Ins. Length [mm] 3 7 22 A 50 13 17 32 A 50 23 27 42 B 70 33 37 52 B 70 43 47 62 C 95 53 57 72 C 95 63 67 82 C 95 with additional bar spacer only Type GC118BR…R: suggested insulator/bolt types S' Min [mm] S Min [mm] S Max [mm] (3) Ins. Length [mm] 3 7 22 A 50 * 13 17 32 A 50 * 23 27 42 A 50 33 37 52 A 50 43 47 62 B 70 53 57 72 B 70 63 67 82 C 95 with additional bar spacer only * For S Max Type GC118SN…R: suggested insulator/bolt types S' Min [mm] S Min [mm] S Max [mm] (3) Ins. Length [mm] 12 16 31 A 50 22 26 41 B 70 32 36 51 B 70 42 46 61 C 95 52 56 71 C 95 62 66 81 C 95 72 76 91 D 120 with additional bar spacer only Type GC118SR…R: suggested insulator/bolt types S' Min [mm] S Min [mm] S Max [mm] (3) Ins. Length [mm] 37 41 56 B 70 47 51 66 B 70 57 61 76 B 70 67 71 86 C 95 77 81 96 C 95 87 91 106 D 120 97 101 116 D 120 ** with additional bar spacer only Document GC118…RT001 160 130 115 129 159 169 179 189 165 175 150 110 120 140 F 160 189 D 140 169 E 150 179 B 120 149 C 130 159 (4) T [mm] A 110 139 Z Bolt Length [mm] 100 129 F 160 170 Allowed clearance S Insulator choice Max heightBolt choice D 140 150 E 150 160 B 120 130 C 130 140 (4) T [mm] A 110 120 Z Bolt Length [mm] 100 110 Allowed clearance S Insulator choice Max heightBolt choice 140 Bolt Length [mm] 139 149 125 135 145 155 100 100Z Bolt Length [mm] T [mm] Max height T [mm] 150 160 110 120 130 E Allowed clearance S Insulator choice F B C D (4) A Bolt choice (4) A E F B C D Z Allowed clearance S Insulator choice Bolt choice Max height D = pressure disc in place of pressure bar blank = no accessories S = extra bar spacer see table below see table below B = with double bar S = with single bar N = upper side R = lower side KK

BAR CLAMP FOR HOCKEY PUK DEVICES GC118…R Dimensions in mm - Tolerances according to ISO 2768 MK Document GC118…RT001 T 145 S29 118 Ø12 118 Ø12 T 145 S48 Ø12 118 145 T S 145 T S 118 Ø12 BAR CLAMP OUTLINES 25 4 27.5 27.527.5 27.5 7325 25 25 22 Min. 1425 50 up to 120 50 up to 12050 up to 120 50 up to 120 1425 2525 106 106 106 106

BAR CLAMP FOR HOCKEY PUK DEVICES GC118…R SPECIAL ACCESSORIES The following special accessories are available on request (see ordering information table) Bar spacer Pressure disc Useful for grooved heatsink Suggested groove diameter 27mm +/- 0.5 Dimensions in mm - Tolerances according to ISO 2768 MK Document GC118…RT001 In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. 145 Ø134 Ø24 S Min S' Min S Max PRESSURE DISC OPTIONAL BAR SPACER