Phone: +39-011-988 2251 Fax: +39-011-988 1358 http://gpsemi.it/pdf/TECT082,_095.pdf TECT082,_095 THREE SCR MODULES Preliminary Data Sheet ► Extremely high power density ► Line voltage range up to 690 VRMS ► High reliability ► Modularity ► User friendly assembly and maintenance ► Cost effective solution ► Suitable for heavy duty applications Maximum Ratings IT(AV) 825 950 A IT(RMS) 1295 1492 A ITSM 34 36 50 Hz, Tj = Tjmax, VR = 0 V kA ITSM 35.9 38.0 60 Hz, Tj = Tjmax, VR = 0 V kA I²t 5780 6480 50 Hz, Tj = Tjmax, VR = 0 V kA²s I²t 5260 5897 60 Hz, Tj = Tjmax, VR = 0 V kA²s VDRM/VRRM 2200 1800 Tj = Tjmax V Tjmax 125 125 °C Document TECT082,_095T001 180° cond, half sine Ta = 40 °C Air velocity = 8 m/s Conditions UnitsPart number TECT082 TECT095
Description
Web: www.gpsemi.it e-mail: info@gpsemi.it
TECT082,_095 V code On-State Characteristics TECT082 TECT095 Conditions Units VT(TO) Threshold voltage 0.99 0.8 Tj = Tjmax V rT On-state slope resistance 0.21 0.18 Tj = Tjmax mW IH Holding current, max 300 300 Tj = 25°C mA IL Latching current, typ 700 700 Tj = 25°C mA PMAX Max power losses 3495 3495 TA = 40°C W Triggering Characteristics TECT082 TECT095 Conditions Units VGT Gate trigger voltage 3 3.5 Tj = 25°C, VD = 5V V IGT Gate trigger current 250 300 Tj = 25°C, VD = 5V mA PGM Peak gate power dissipation 150 150 Pulse width 1 ms W PG(AV) Average gate power dissipation 2 2 W IFGM Peak gate current 10 10 A VFGM Peak gate voltage (forward) 30 30 V VRGM Peak gate voltage (reverse) 12 5 V Switching Characteristics TECT082 TECT095 Conditions Units di/dt Critical rate of rise of on-state current 200 200 Tj = Tjmax A/µs dV/dt Critical rate of rise of off-state voltage 1000 1000 Tj = Tjmax V/µs tq Turn-off time, typ 450 400 Tj=Tjmax, IT=1000A di/dt=-20A/µs VR=50V dV/dt=20V/µs µs Document TECT082,_095T001 max repetitive reverse and off-state blocking voltage [V][V] 500 VL(RMS) 400 IDRM IRRM @ Tjmax VDRM VRRM maximum suggested RMS line voltagePart Number Parameters Parameters Parameters 1200 1600 1800 TECT095 2200 690TECT082 550
TECT082,_095 1.0 0 24 Maximum IEC class 1 currents for typical circuit type TECT082 TECT095 Conditions Units AC switch A Center tap 1650 1900 A Two pulse regen bridge A Six pulse regen bridge 2360 2700 A Double star with I.P. transf. 1.5;1 min 1.0 0 24 Maximum IEC class 2 currents for typical circuit type TECT082 TECT095 Conditions Units AC switch TA = 40 °C delay angle = 0° A Center tap TA = 40 °C delay angle = 0° A Two pulse bridge Six pulse bridge Thermal and mechanical characteristics TECT082 TECT095 Conditions Units Tjmax Max operating junction temperature 125 125 °C Tstg Storage temperature -40 +70 -40 +70 °C RthJA Thermal resistance (junction to ambient) 0.073 0.073 Air velocity = 8 m/s °C/W Mounting torque - TEC to panel (+/- 10%) N·m Mounting torque - busbar to TEC (+/- 10%) 14 14 M8 mounting screw N·m D Depth 265 mm H Height 375 mm W Width mm m Mass kg Document TECT082,_095T001 Ta = 40 °C Air velocity = 8 m/s Circuit Type Parameters F Circuit Type Overall dimensions H D
TECT082,_095 TECT 095 - 18 - 0 0 1 1 2 3 4 5 6
1 Circuit configuration = three SCR separately insulated in a single stack (*)
2 Average current / 10
3 Blocking voltage / 100
4 0 = No fuse - 1 = with fuse for regen application 5 0 = no blown-fuse microsiwitch 6 0 = No snubber - 3 = three RC snubber - S = three snubber resistor (*) How to connect two TECT modules to obtain a six-pulse bridge Document TECT082,_095T001 PART-NUMBERING SYSTEM