Datasheet sections
- 2.1 Display Characteristics
- 2.2 Optical Characteristics
- 4.1 Absolute Ratings of TFT LCD Module
- 4.2 Absolute Ratings of Environment
- 5.1 TFT LCD Module
- 5.2 Backlight Unit
- 6.1 Pixel Format Image
- 6.2 Scanning Direction
- 6.3 TFT-LCD Interface Signal Description
- 6.4 The Input Data Format
- 6.5 TFT-LCD Interface Timing
- 6.6 Power ON/OFF Sequence
- 7.1 TFT-LCD Signal (CN1): LVDS Connector
- 7.2 LED Backlight Unit (CN2): Driver Connector
- 7.3 LED Backlight Unit (CN3): Light bar Connector
- 9.1 LCM Outline Dimension (Front View)
- 9.2 LCM Outline Dimension (Rear View)
- 10.1 Shipping Label (on the rear side of TFT-LCD display)
- 10.2 Carton Package
- 11 Safety
- 11.1 Sharp Edge Requirements
- 11.2 Materials
- 11.3 Capacitors
- 11.4 National Test Lab Requirement
G104XVN01.0 rev. 1.4 Page 1/25 G104XVN01.0 ( ) Preliminary Specifications ( V ) Final Specifications Module 10.4 Inch Color TFT-LCD Model Name G104XVN01.0 Customer Date Checked & Approved by Note: This Specification is subject to change without notice. Approved by Date Grace Hung 2014/7/21 Prepared by Mask Tsai 2014/7/21 General Display Business Division / AU Optronics corporation For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 3/25 G104XVN01.0 Record of Revision Version and Date Page Old description New Description 0.0 2012/07/15 All First Edition 0.1 2012/09/11 22 LVDS CN1 pin1 is on the right CN1 pin1 is on the left 0.2 2013/04/20 6 Contrast ratio typ=1400 Weight 350g Contrast ratio typ=3000 Weight 295g
11 IVDD typ=200 IVDD typ=20
Correct some drawing dimension 23 Max. Weight: 14.5 kg / per carton Max. Weight: 15.5 kg / per carton 1.0 2013/07/20 6 Add R,G,B chromaticity Absolute ratings of environment operation and storage humidity 95 Operation and storage humidity 90 Add dew point chart
13 Add maximum value of backlight LED forward
voltage and power consumption
20 Add Note 3, Note 4
1.2 2014/05/27 15 6.3 TFT-LCD Interface Signal Description Pin3:GND & Pin4:VCC for 6 Bit Input Mode Note4 1.3 2014/7/2 13 Add Operation Life: Typ 70,000 Hrs 1.4 2014/7/2 13 Modify Operation Life: Typ 80,000 Hrs 1.5 2014/12/15 6 Modify optical charateristics For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 4/25 G104XVN01.0 1. Operating Precautions 1) Since front polarizer is easily damaged, please be cautious and not to scratch it. 2) Be sure to turn off power supply when inserting or disconnecting from input connector. 3) Wipe off water drop immediately. Long contact with water may cause discoloration or spots. 4) When the panel surface is soiled, wipe it with absorbent cotton or soft cloth. 5) Since the panel is made of glass, it may be broken or cracked if dropped or bumped on hard surface. 6) To avoid ESD (Electro Static Discharge) damage, be sure to ground yourself before handling TFT-LCD Module. 7) Do not open nor modify the module assembly. 8) Do not press the reflector sheet at the back of the module to any direction. 9) In case if a module has to be put back into the packing container slot after it was taken out from the container, do not press the center of the LED light bar edge. Instead, press at the far ends of the LED light bar edge softly. Otherwise the TFT Module may be damaged. 10) At the insertion or removal of the Signal Interface Connector, be sure not to rotate nor tilt the Interface Connector of the TFT Module. 11) TFT-LCD Module is not allowed to be twisted & bent even force is added on module in a very short time. Please design your display product well to avoid external force applying to module by end-user directly. 12) Small amount of materials without flammability grade are used in the TFT-LCD module. The TFT-LCD module should be supplied by power complied with requirements of Limited Power Source (IEC60950 or UL1950), or be applied exemption. 13) Severe temperature condition may result in different luminance, response time and lamp ignition voltage. 14) Continuous operating TFT-LCD display under low temperature environment may accelerate lamp exhaustion and reduce luminance dramatically. 15) The data on this specification sheet is applicable when LCD module is placed in landscape position. 16) Continuous displaying fixed pattern may induce image sticking. It’ s recommended to use screen saver or shuffle content periodically if fixed pattern is displayed on the screen. For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 5/25 G104XVN01.0 2. General Description This specification applies to the Color Active Matrix Liquid Crystal Display G104XVN01.0 composed of a TFT-LCD display, a driver and power supply circuit, and a LED backlight system. The screen format is intended to support XGA (1024(H) x 768(V)) screen and 16.2M (RGB 8-bits) or 262k colors (RGB 6-bits). LED driving board for backlight unit is included in G104XVN01.0. G104XVN01.0 designed with wide viewing angle; wide temperature and long life LED backlight is well suited for industial applications. G104XVN01.0 is a RoHS product.
2.1 Display Characteristics
The following items are characteristics summary on the table under 25 Ċ condition: Items Unit Specifications Screen Diagonal [inch] 10.4 Active Area [mm] 210.4 (H) x 157.8 (V) Pixels H x V 1024 x 3(RGB) x 768 Pixel Pitch [mm] 0.2055 x 0.2055 Pixel Arrangement R.G.B. Vertical Stripe Display Mode PSA, Normally Black Nominal Input Voltage VDD [Volt] 3.3 (typ.) Typical Power Consumption [Watt] 6.0W All black pattern Weight [Grams] 295(Typ.) Physical Size [mm] 238.6(H) x 175.8(V) x 6.5(D)(Typ.) Electrical Interface 1 channel LVDS Surface Treatment Anti-glare, Hardness 3H Support Color 16.2M / 262K colors Temperature Range Operating Storage (Non-Operating) [oC] [oC] -30 to +80 -30 to +80 RoHS Compliance RoHS Compliance For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 6/25 G104XVN01.0
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25 (Room Temperature):Ċ Item Unit Conditions Min. Typ. Max. Remark White Luminance [cd/m2] IF= 80mA/1 LED Line (center point) 350 470 - Note 1 Uniformity % 5 Points 75 80 - Note 2, 3 Contrast Ratio 2500 3000 - Note 4 [msec] Rising - 20 30 [msec] Falling - 10 20Response Time [msec] Raising + Falling - 30 50 Note 5 [degree] [degree] Horizontal (Right) CR = 10 (Left) -Viewing Angle [degree] [degree] Vertical (Upper) CR = 10 (Lower) Note 6 Red x 0.570 0.620 0.670 Red y 0.280 0.330 0.380 Green x 0.300 0.350 0.400 Green y 0.530 0.580 0.630 Blue x 0.100 0.150 0.200 Blue y 0.010 0.060 0.110 White x 0.263 0.313 0.363 Color / Chromaticity Coordinates (CIE 1931) White y 0.279 0.329 0.379 Color Gamut % - 60 - Note 1: Measurement method Equipment Pattern Generator, Power Supply, Digital Voltmeter, Luminance meter (SR_3 or equivalent) Aperture 1 with 50cm viewing distance∘ Test Point Center Environment < 1 lux LCD Module SR_3 or equivalent Measuring distance Module Driving Equipment For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 7/25 G104XVN01.0 Note 2: Definition of 5 points position (Display active area: 210.4mm (H) x 157.8mm (V)) 1 2 4 5 H /4 H /4 H /4 H /4 H W W /4 W /4 W /4 W /4 Note 3: The luminance uniformity of 5 points is defined by dividing the minimum luminance values by the maximum test point luminance Note 4: Definition of contrast ratio (CR): Note 5: Definition of response time: The output signals of photo detector are measured when the input signals are changed from “White” to “ Black” (falling time) and from “ Black” to “ White” (rising time), respectively. The response time interval is between 10% and 90% of amplitudes. Please refer to the figure as below. Note 6: Definition of viewing angle Viewing angle is the measurement of contrast ratio 10, at the screen centÚ er, over a 180° horizontal and 180° vertical range (off-normal viewing angles). The 180° viewing angle range is broken down as below: 90° (θ) horizontal left and right, and 90° (Φ) vertical high (up) and low (down). The measurement direction is typically perpendicular to the display surface with the screen rotated to its center to develop the desired Minimum Brightness of five points ƼW9 = Maximum Brightness of five points Contrast ratio (CR)= Brightness on the “White” state Brightness on the “Black” state 100 Optical response White Black White Tf Tr Optical response White Black White Tr For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 8/25 G104XVN01.0 measurement viewing angle. For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 9/25 G104XVN01.0 3. Functional Block Diagram The following diagram shows the functional block of the 10.4 inch color TFT/LCD module: For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 10/25 G104XVN01.0 4. Absolute Maximum Ratings
4.1 Absolute Ratings of TFT LCD Module
Logic/LCD Drive Voltage Vin -0.3 6 [Volt]
4.2 Absolute Ratings of Environment
Operating Temperature TOP -30 +80 [oC] Operation Humidity HOP 5 90 [%RH] Storage Temperature TST -30 +80 [oC] Storage Humidity HST 5 90 [%RH] Note: Maximum Wet-Bulb should be 39 Ċ and no condensation. %FXQPJOUGPSXFUCVMCUFNQFSBUVSFĊ 5FNQFSBUVSF Ċ 3FMBUJWFIVNJEJUZ Twb=39Ċ, RH=90% For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 11/25 G104XVN01.0 5. Electrical Characteristics
5.1 TFT LCD Module
5.1.1 Power Specification
Symbol Parameter Min Typ Max Units Remark VDD Logic/LCD Input Voltage 3.1 3.3 3.5 [Volt] IVDD LCD Input Current - 300 [mA] VDD=3.3V at 60 HZ, all Black Pattern PVDD LCD Power comsumption - 0.99 [Watt] VDD=3.3V at 60 HZ, all Black Pattern Irush LCD LCD Inrush Current - - 1.5 [A] Note 1; VDD=3.3V Black Pattern, Rising time=470us VDDrp Allowable Logic/LCD Drive Ripple Voltage - 100 [mV] p-p VDD=3.3V at 60 HZ, all Black Pattern Note 1: Measurement condition: AO6402 G D2S AO6402 G D2 S 1uF/16V 1uF/25V 0.01uF/25V VR1 47K +12.0V VCC SW1 SW MAG-SPST 1 2 (High to Low) Control Signal (LCD Module Input) +3.3V 47K 90% 10% VDD rising time 3.3V 470 us VDD For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 12/25 G104XVN01.0
5.1.2 Signal Electrical Characteristics
Input signals shall be low or Hi-Z state when VDD is off. Note: LVDS Signal Waveform. Symbol Item Min. Typ. Max. Unit Remark VTH Differential Input High Threshold - - 100 [mV] VCM=1.2V VTL Differential Input Low Threshold 100 - - [mV] VCM=1.2V xVIDx Input Differential Voltage 100 400 600 [mV] VICM Differential Input Common Mode Voltage 1.1 - 1.45 [V] VTH/VTL=+-100mV For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 13/25 G104XVN01.0
5.2 Backlight Unit
5.2.1 Parameter guideline for LED backlight
Following characteristics are measured under a stable condition using a inverter at 25 Ċ. (Room Temperature): Symbol Parameter Min. Typ. Max. Unit Remark VCC Input Voltage 10.8 12 12.6 [Volt] I VCC Input Current - 0.5 - [A] 100% PWM Duty PVCC Power Consumption - 6 - [Watt] 100% PWM Duty IINRUSH LED Inrush Current - - 3 A VLED rising time ~ 470us FPWM Dimming Frequency 200 - 20K [Hz] On Control Voltage 2.5 3.3 5.5 Volt VLED ON/OFF Off Control Voltage - - 0.8 Volt Note 4,5 VPWM DIM Swing Voltage 2.5 3.3 5.5 [Volt] Dimming duty cycle 5 - 100 % IF LED Forward Current - 80 - [mA] Ta = 25oC - - 34.2 [Volt] IF = 80mA, Ta = -30oC - 29.7 32.4 [Volt] IF = 80mA, Ta = 25oCVF LED Forward Voltage - - 31.5 [Volt] IF = 80mA, Ta = 80oC PLED LED Power Consumption - 4.75 5.47 [Watt] 2 String of LED Light Bar Operation Life 50,000 80,000 - Hrs IF=80mA, Ta= 25oC Note 1: Ta means ambient temperature of TFT-LCD module. Note 2: VCC, IVCC, Irush LED, PVCC are defined for LED backlight.(100% duty of PWM dimming) Note 3: IF, VF are defined for one channel LED. There are two LED channel in back light unit. Note 4: PWM dimming function can be operated by PWM signal. PWM duty cycle can adjust white Luminance. (PWM High: ON and PWM Low: OFF) Note 5: PWM signal can not be floating and pull-down to ground when waiting. Note 6: If G104XVN01.0 module is driven by high current or at high ambient temperature & humidity condition. The operating life will be reduced. Note 7: Operating life means brightness goes down to 50% initial brightness. Minimum operating life time is estimated data. For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 14/25 G104XVN01.0 6. Signal Characteristics
6.1 Pixel Format Image
Following figure shows the relationship between input signal and LCD pixel format. 1st Pixel 2nd Pixel 1023th Pixel 1024th Pixel 1st Line R G B R G B R G B R G B 768th Lin R G B R G B R G B R G B
6.2 Scanning Direction
The following figures show the image seen from the front view. The arrow indicates the direction of scan. Fig. 1 Normal scan (Pin24, Reverse = Low or NC) Fig. 2 Reverse scan (Pin24, Reverse = High) For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 15/25 G104XVN01.0
6.3 TFT-LCD Interface Signal Description
The module using a LVDS receiver embaded in AUO’ s ASIC. LVDS is a differential signal technology for LCD interface and a high-speed data transfer device. Pin No. Signal Name Description
1 NC No Connection
2 GND Ground
Rin3+ Positive LVDS differential data input (+) GND for 6 Bit Input Mode Note4 Rin3- Negative LVDS differential data input (-) VCC for 6 Bit Input Mode Note4
5 GND Ground
6 CLK+ Clock signal (+)
7 CLK- Clock signal (-)
8 GND Ground
9 Rin2+ Positive LVDS differential data input (+)
10 Rin2- Negative LVDS differential data input (-)
11 GND Ground
12 Rin1+ Positive LVDS differential data input (+)
13 Rin1- Negative LVDS differential data input (-)
14 GND Ground
15 Rin0+ Positive LVDS differential data input (+)
16 Rin0- Negative LVDS differential data input (-)
17 GND Ground
18 NC No Connection
19 GND Ground
20 SEL6/8
Selection for 6 bits/8bits LVDS data input Low or NC -> 8 bit Input Mode High -> 6bit Input Mode
21 NC No Connection
22 NC No Connection
23 NC No Connection
24 Reverse Reverse Panel Function (Display Rotation)
25 GND Ground
26 GND Ground
27 GND Ground
28 VCC Power supply: +3.3V 29 VCC Power supply: +3.3V 30 VCC Power supply: +3.3V For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 16/25 G104XVN01.0 Note 1: Input Signals shall be in low status when VCC is off. Note 2: High stands for “ 3.3V” , Low stands for “ 0V” , NC stands for “ No Connection” . Note 3: RSV stands for “ Reserved” . Note 4: For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 17/25 G104XVN01.0
6.4 The Input Data Format
6.4.1 SEL68
SEL68 = “High” for 6 bits LVDS Input SEL68 = “Low” or “NC” for 8 bits LVDS Input Note1: Please follow PSWG. Note2: R/G/B data 7:MSB, R/G/B data 0:LSB Signal Name Description Remark Red Data 7 Red Data 6 Red Data 5 Red Data 4 Red Data 3 Red Data 2 Red Data 1 Red Data 0 Red-pixel Data For 8Bits LVDS input MSB: R7 ; LSB: R0 For 6Bits LVDS input MSB: R5 ; LSB: R0 Green Data 7 Green Data 6 Green Data 5 Green Data 4 Green Data 3 Green Data 2 Green Data 1 Green Data 0 Green-pixel Data For 8Bits LVDS input MSB: G7 ; LSB: G0 For 6Bits LVDS input MSB: G5 ; LSB: G0 Blue Data 7 Blue Data 6 Blue Data 5 Blue Data 4 Blue Data 3 Blue Data 2 Blue Data 1 Blue Data 0 Blue-pixel Data For 8Bits LVDS input MSB: B7 ; LSB: B0 For 6Bits LVDS input MSB: B5 ; LSB: B0 RxCLKIN LVDS Data Clock DE Data Enable Signal When the signal is high, the pixel data shall be valid to be displayed. Note: Output signals from any system shall be low or Hi-Z state when VDD is off. NS-like format For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 18/25 G104XVN01.0
6.5 TFT-LCD Interface Timing
6.5.1 Timing Characteristics
Signal Symbol Min. Typ. Max. Unit Clock Frequency 1/ TClock 50 65 81 MHz Period TV 776 806 1023 Active TVD 768 768 768Vertical Section Blanking TVB 8 38 256 TLine Period TH 1054 1344 2047 Active THD 1024 1024 1024Horizontal Section Blanking THB 30 320 1023 TClock Frame Rate F 50 60 75 Hz Note : DE mode.
6.5.2 Input Timing Diagram
Input Timing Definition ( DE Mode)TCLOCK Input Data Pixel Pixel Pixel Pixel N-1 Pixel N Invaild Data Invaild Data Pixel For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 19/25 G104XVN01.0
6.6 Power ON/OFF Sequence
VDD power and lamp on/off sequence is as below. Interface signals are also shown in the chart. Signals from any system shall be Hi-Z state or low level when VDD is off. Power ON/OFF sequence timing Value Units Parameter Min. Typ. Max. T1 0.5 - 10 [ms] T2 30 40 50 [ms] T3 200 -- -- [ms] T4 0.5 -- 10 [ms] T5 10 - - [ms] T6 10 - - [ms] T7 0 - - [ms] T8 10 - - [ms] T9 -- -- 10 [ms] T10 110 -- -- [ms] T11 0 16 50 [ms] T12 - - 10 [ms] T13 1000 - - [ms] The above on/off sequence should be applied to avoid abnormal function in the display. Please make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 20/25 G104XVN01.0 7. Connector & Pin Assignment Physical interface is described as for the connector on module. These connectors are capable of accommodating the following signals and will be following components.
7.1 TFT-LCD Signal (CN1): LVDS Connector
Connector Name / Designation Signal Connector Manufacturer JAE or compatible Connector Model Number '*91#43-")'or compatible Adaptable Plug '*9)-PS$PNQBUJCMF or compatible Pin No. Symbol Pin No. Symbol
1 NC 16 Rin0-
2 GND 17 GND
3 Rin3+ 18 NC
4 Rin3- 19 GND
5 GND 20 SEL6/8
6 CLK+ 21 NC
7 CLK- 22 NC
8 GND 23 NC
9 Rin2+ 24 Reverse
10 Rin2- 25 GND
11 GND 26 GND
12 Rin1+ 27 GND
13 Rin1- 28 VCC
14 GND 29 VCC
15 Rin0+ 30 VCC
7.2 LED Backlight Unit (CN2): Driver Connector
Connector Name / Designation Lamp Connector Manufacturer ENTERY or compatible Connector Model Number 3808K-F05N-02R or compatible Mating Model Number H208K–P05N-02B or compatible Pin No. symbol description Pin1 VCC 12V input Pin2 VCC 12V input Pin3 GND GND Pin4 Dimming PWM Pin5 On/OFF 3.3V or 5V-ON,0V-OFF For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 21/25 G104XVN01.0
7.3 LED Backlight Unit (CN3): Light bar Connector
Connector Name / Designation Lamp Connector Manufacturer ENTERY or compatible Connector Model Number H208K–P03N-02R or compatible Mating Model Number(CN3) 3808K-F03N-02B or compatible Pin No. symbol description Color Pin1 H LED anode Red Pin2 L LED cathode White Pin3 L LED cathode White 8. Reliability Test Criteria Items Required Condition Note Temperature Humidity Bias 40Ċ, 90%RH, 300 hours Note3 High Temperature Operation 80Ċ, 300 hours Note3 Low Temperature Operation -30Ċ, 300 hours Note3 Hot Storage 80 ,Ċ 300 hours Note3 Cold Storage -30 ,Ċ 300 hours Note3 Thermal Shock Test -20 /Ċ 30 min, 60 /Ċ 30 min, 100cycles, 40 Ċ minimum ramp rate Note3 Hot Start Test 80Ċ/ 1Hr min. power on/off per 5 minutes, 5 times Cold Start Test -30Ċ/ 1Hr min. power on/off per 5 minutes, 5 times Shock Test (Non-Operating) 50G, 20ms, Half-sine wave, ( ±X, ±Y, ±Z) Vibration Test (Non-Operating) 1.5G, (10~200Hz, Sine wave) 30 mins/axis, 3 direction (X, Y, Z) On/off test On/10 sec, Off/10 sec, 30,000 cycles Note4 ESD Contact Discharge: ± 8KV, 150pF(330Ω ) 1sec, 8 points, 25 times/ point Air Discharge: ± 15KV, 150pF(330Ω ) 1sec, 8 points, 25 times/ point Note1 EMI 30-230 MHz, limit 40 dBu V/m, 230-1000 MHz, limit 47 dBu V/m Note1: According to EN61000-4-2, ESD class B: Some performance degradation allowed. No data lost Self-recoverable. No hardware failures. Note2: Water condensation is not allowed for each test items. Each test is done by new TFT-LCD module. Don’ t use the same TFT-LCD module repeatedly for reliability test. The reliability test is performed only to examine the TFT-LCD module capability. Note3. To inspect TFT-LCD module after reliability test, please store it at room temperature and room humidity for 2 hours at least in advance. Note4. Judged by the on/off testing results of AUO’ s standard w/o functional fail For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 22/25 G104XVN01.0 9. Mechanical Characteristics
9.1 LCM Outline Dimension (Front View)
For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 23/25 G104XVN01.0
9.2 LCM Outline Dimension (Rear View)
For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 24/25 G104XVN01.0 10. Label and Packaging
10.1 Shipping Label (on the rear side of TFT-LCD display)
10.2 Carton Package
Note: 1. Max. Capacity: 40pcs LCD Modules / per carton 2. Max. Weight: 15.5 kg / per carton 3. The outside dimension of carton is 458(L) mm x 412(W) mm x 368(H) mm G104XVN01.0 For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
G104XVN01.0 rev. 1.4 Page 25/25 G104XVN01.0
11 Safety
11.1 Sharp Edge Requirements
There will be no sharp edges or comers on the display assembly that could cause injury.
11.2 Materials
11.2.1 Toxicity
There will be no carcinogenic materials used anywhere in the display module. If toxic materials are used, they will be reviewed and approved by the responsible AUO toxicologist.
11.2.2 Flammability
All components including electrical components that do not meet the flammability grade UL94-V1 in the module will complete the flammability rating exception approval process. The printed circuit board will be made from material rated 94-V1 or better. The actual UL flammability rating will be printed on the printed circuit board.
11.3 Capacitors
If any polarized capacitors are used in the display assembly, provisions will be made to keep them from being inserted backwards.
11.4 National Test Lab Requirement
The display module will satisfy all requirements for compliance to: UL 1950, First Edition U.S.A. Information Technology Equipment For DD Internal Use Only - Provided By pavelkonvalinka On 2016/02/29 AUO Confidential For DD Internal Use Only On 2016/02/29
Our company network supports you worldwide with offices in Germany, Austria, Switzerland, the UK and the USA. For more information please contact: Headquarters Germany FORTEC Elektronik AG Lechwiesenstr. 9
86899 Landsberg am Lech
Phone: +49 8191 91172-0 E-Mail: sales@fortecag.de Internet: www.fortecag.de Fortec Group Members Austria FORTEC Elektronik AG Office Vienna Nuschinggasse 12
1230 Wien
Phone: +43 1 8673492-0 E-Mail: office@fortec.at Internet: www.fortec.at Germany Distec GmbH Augsburger Str. 2b
82110 Germering
Phone: +49 89 894363-0 E-Mail: info@distec.de Internet: www.distec.de Switzerland ALTRAC AG Bahnhofstraße 3
5436 Würenlos
Phone: +41 44 7446111 E-Mail: info@altrac.ch Internet: www.altrac.ch United Kingdom Display Technology Ltd. Osprey House, 1 Osprey Court Hichingbrooke Business Park Huntingdon, Cambridgeshire, PE29 6FN Phone: +44 1480 411600 E-Mail: info@displaytechnology.co.uk Internet: www. displaytechnology.co.uk USA Apollo Display Technologies, Corp.
87 Raynor Avenue,
Unit 1Ronkonkoma, NY 11779 Phone: +1 631 5804360 E-Mail: info@apollodisplays.com Internet: www.apollodisplays.com