Tektronix FCA3000 and FCA3100 Series Datasheet Features & Benefits Key Performance Specifications

300 MHz, 3 GHz, 20 GHz Models

300-400 MHz in Manual Trigger Mode Up to 3 Input Channels 50 ps (FCA3100 Series) or 100 ps (FCA3000 Series) Single-shot Time Resolution

12 Digit/s Frequency Resolution

0.001° Phase Resolution 3m Vo rb etter Voltage Resolution Optional 5×10–8 High-stability Oven Time Base Measurement Throughput 250k Sample/s Data Transfer Rate to Internal Memory (Up to 3.75M samples stored) Up to 15k Sample/s Data Transfer Rate over USB/GPIB Bus (Block mode) Up to 650 Individually Triggered Measurements/s Available Functions and Features Automated Measurements: Frequency, Period, Ratio, Time Interval, Time Interval Error, Pulse Width, Rise/Fall Time, Phase Angle, Duty Cycle, Maximum Voltage, Minimum Voltage, Peak-to-Peak Voltage Totalize Measurement (FCA3100 Series) Multi-parameter Display Trend Plot Mode Measurement Statistics Mode Histogram Mode Allan Deviation Zero Dead-time Frequency/Period Measurements Continuous Data Streaming over USB/GPIB Bus during Measurement (FCA3100 Series) Programmable Pulse Output from 0.5 Hz to 50 MHz Connectivity Optional Rear-panel Inputs USB Device and GPIB Ports on Rear Panel for Quick PC Connectivity GPIB Interface Supports Full SCPI-compatible Programmability and offers an Emulation Mode for Plug-and-Play Replacement in Existing ATE Systems External Arming Input

10 MHz Reference Oscillator Output

Includes National Instrument's LabVIEW SignalExpress™ TE Limited Edition Software for Connecting Your Bench Optional TimeView™ Software Available for Modulation Domain Analysis 3-year Warranty

Feature-rich Tools for Precision Measurements The FCA3000 and FCA3100 Timer/Counter/Analyzer Series pack many different functions into one feature-rich instrument. With industry-leading frequency and time resolution, the FCA Series comes standard with deep internalmemory and a fast data transfer rate of 250k Samples/s to internal memory. In addition, the multi-parameter display shows auxiliary measurements alongside your main measurement to provide you with the results you need at a glance. With the industry's most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal. Industry-leading Performance for Demanding Designs High-resolution is critical for R&D and production testing on today's demanding designs. The FCA Series delivers 12-digit/s frequency resolution and for time measurements, single-shot resolution of 50 ps (FCA3100 Series) or 100 ps (FCA3000 Series) is available with measurement values displayed up to 14 digits. With industry-leading performance, the FCA Series provides you with fast, precise measurements. Unique Features for Accurate Measurements To ensure correct measurements of Allan Deviation, the FCA3100 Series offers a zero dead-time measurement technique and continuous time stamping oftrigger events. This feature is vital for mechanical and medical measurements where every single cycle must be measured. The FCA3000 Series offers this functionality through the USB/GPIB interfaces with a raw time-stamping function. For correct calculation of statistical parameters, the FCA Series comes standard with limit-qualifying capability. By setting limits, you can isolate one cluster in your calculation. This is important for applications such as verifying the jitter of digital pulses that appear in discrete clusters in CD players orin HDB3-coded data. Also available is hysteresis compensation for time interval measurements. By adding hysteresis, you can reduce trigger-level error from the typical 15-20 mV found in most counters on the market today, down to a typical 2.5 mV. This means 6-8 times improved trigger precision in critical time interval measurements. Fast Throughput Reduces Test Time The FCA Timer/Counter/Analyzer Series offers industry-best throughput, saving you up to 90% on your testing time compared to other timer/counters on the market. Up to 250,000 measurement results per second can be Multi-parameter Display. Phase Relationship Measurement. stored in the internal memory. Alternatively, you can transfer up to 15,000 measurement results per second in Block mode through the GPIB or USB interface. For addedflexibility, the FCA3100 Series offers a zero dead-time counter feature to continuously stream measurement data over the GPIB/USB bus during, not after, measurement. This creates a dynamic measurement and analysis system. Analyze Your Device with the Industry's Only Graphical Display With the unique display of the FCA Series, you can measure multiple parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittent transients, and stability, you can view the data as a real-time trend plot or a histogram with the FCA Series graphical display mode, or you can use measurement statistics to track how signal parameters are changing over time. A single-button Analyze mode gives you fast insight into the behavior of your device right on the timer/counter's display. Multi-parameter Display With the multi-parameter display, you can read important auxiliary measurement values (such as V max,V min,V p-p, and more) displayed with your main frequency, time, period, or phase measurements. With one glance, you can see the information you need to quickly assess your device's performance. With up to 3 input channels, you can measure the relationship between different signals. For example, you can measure the phase relationship between the input and output signals of your device. You can read other critical parameters simultaneously, such as the test frequency of the signal and the voltage ratio (in dB), in one glance with the multi-parameter display. 2 www.tektronix.com

Timer/Counter/Analyzers — Tektronix FCA3000 and FCA3100 Series Trend Plot Analysis. Measurement Statistics. Histogram Plot. Measurement Trend Plots Depending on your test case, your signal parameters may change from instant to instant. With the Trend Plot Analysis mode, you can graphically plot the trend of a measured value over time. Measurement Statistics With integrated statistics processing, you can calculate the average, standard, and Allan deviation of a measurement, as well as track the minimum and maximum measured values, all with the push of a button. Histogram Plots To graphically see the average and standard deviation of a set of measurements, you can use the histogram function to see the distribution of measurement results. Optional Modulation Domain Analysis With the optional Tektronix TimeView™ software (TVA3000), the FCA Timer/Counter/Analyzer Series can become a high-performance modulation domain analyzer. With high measurement speeds (up to Tektronix TimeView™ Software. 250k measurement/s) and large memory depth (up to 3.75M points), fast frequency changes can be captured in real time and then analyzed with TimeView. This comprehensive software tool allows for remote instrument control, and the analysis and display of measurement results in a choice of graphs. For example, results can be displayed as raw data, statistical histogram, waveform graph (as if you were using an oscilloscope), or as an FFT spectrum graph. TimeView further allows analysis of modulation parameters like modulation depth or frequency modulation index. Designed to Make Your Work Easier The FCA Timer/Counter/Analyzer Series are designed with the ease of use and familiar operation you have come to expect from Tektronix. Intuitive Operation Menu-oriented settings reduce the risk of mistakes. With dedicated and menu-driven front-panel buttons, you will have fast access to frequently used functions and parameters, reducing setup time. For example, a single-touch Analyze key toggles you between Statistics, Trend Plot, and Histogram modes. Autoset Function Similar to Tektronix oscilloscopes, the front-panel Autoset button will automatically set optimum trigger levels and hysteresis adapted to the actual signal applied. Easy PC Connectivity Connect to your PC with the rear-panel GPIB or USB device ports. The GPIB interface operates in SCPI/GPIB for plug-and-play replacement in existing ATE systems or easy integration into larger test systems. If desired, an emulation mode for existing timer/counters is available. www.tektronix.com 3

Connect Your Bench for Intelligent Debug Easily capture, save, and analyze measurement results from your FCA Series timer/counter/analyzer with the special Tektronix Edition of National Instruments LabVIEW SignalExpress™ software. Every FCA Series timer/counter/analyzer ships with a free copy of the Limited Edition version of SignalExpress for basic instrument control, data logging, and analysis. The optional Professional Edition offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, limit testing, and user-defined step capabilities. SignalExpress supports the range of Tektronix bench instruments* enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time-correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. Performance You Can Count On In addition to industry-leading service and support, every FCA Series timer/counter/analyzer comes backed with a three-year standard warranty. Select the Performance/Features to Meet Your Needs Feature FCA3100 Series FCA3000 Series Frequency Resolution 12 digit/s 12 digit/s Time Resolution 50 ps 100 ps Voltage Resolution 1 mV 3 mV Meas. Speed to Internal Memory 250k measurement/s 3.5M results 250k measurement/s 750k results Talker-only Output (GPIB/USB) 4k measurement/s No Individually Triggered Measurements 650/s 500/s Block Transfer Speed 15k measurement/s 5k measurement/s Frequency/Period, Time, Phase, Volt, Duty Cycle, Pulse, Rise Time Yes Yes Graphic Display of Trend, Histogram, Modulation Domain Yes Yes Totalize, TIE Yes No Programmable Pulse Output Yes No Continuous Measurements Yes No *1 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress. Characteristics Measuring Functions All measurements are displayed with a large main parameter value and smaller auxiliary parameter values (with less resolution). Some measurements are only available as auxiliary parameters. Frequency A, B,C Characteristic Description Mode Normal, Back-to-Back (FCA3100 Series) Range Input A, B 0.001 Hz to 300 MHz 300-400 MHz in Manual Trigger mode Input C 100 MHz to 3 GHz or 300 MHz to 20 GHz Resolution 12 digits in 1 s measuring time (normal) 11 digits in 1 s measuring time (back-to-back) Aux Parameters V max,V min,V p-p Frequency Burst A, B, C (FCA3020 and FCA3120 – 20 GHz Only) Frequency and PRF of repetitive burst signals can be measured without an external control signal and with selectable-start arming delay. Characteristic Description Functions Frequency in burst (in Hz) PRF (in Hz) Range Input A, B, C: See Frequency spec. Minimum Burst Duration Down to 40 ns Minimum Pulses in Burst I n p u tA ,B 3 (6 above 160 MHz) Input C 3 × prescaler factor PRF Range 0.5 Hz to 1 MHz Start Delay 10 ns to 2 s, 10 ns resolution Aux Parameters PRF Period A, B, C Characteristic Description Mode Single, Average, Back-to-Back (FCA3100 Series) Range I n p u tA ,B 3.3 ns to 1000 s (single, average) 4.0 µs to 1000 s (back-to-back) Input C 10 ns down to 50 ps Resolution 100 ps (single); 12 digit/s avg. (FCA3000 Series) 50 ps (single); 12 digit/s avg. (FCA3100 Series) Aux Parameters V max,V min,V p-p Ratio A/B, B/A, C/A, C/B Characteristic Description Range (10–9)t o1 011 Input Frequency I n p u tA ,B 0 . 1H zt o3 0 0M H z 300-400 MHz in Manual Trigger mode I n p u tC 3o r2 0G H z Aux Parameters Freq 1, Freq 2 4 www.tektronix.com

Timer/Counter/Analyzers — Tektronix FCA3000 and FCA3100 Series Time Interval A to B, B to A, A to A, B to B Characteristic Description Range Normal calculation: 0 ns to +10 6 s Smart calculation: –106 st o+ 1 06 s Resolution 100 ps single (FCA3000 Series) 50 ps single (FCA3100 Series) Min Pulse Width 1.6 ns Smart Calculation Smart Time Interval to determine sign (A before B or A after B) Positive and Negative Pulse Width A, B Characteristic Description Range 2.3 ns to 10 6 s Min Pulse Width 2.3 ns Aux Parameters V max,V min,V p-p Rise and Fall Time A, B Characteristic Description Range 1.5 ns to 10 6 s Trigger Levels 10% and 90% of signal amplitude Min Pulse Width 1.6 ns Aux Parameters Slew rate, Vmax,V min Time Interval Error (TIE) A, B Normalized period back-to-back measurements, calculated as TIE(k) = k * TREF - ∑TI,w h e nTI = Individual Period Back-to-Back and TREF = Reference Period Value. Positive and Negative Duty Factor A, B Characteristic Description Range 0.000001 to 0.999999 Frequency Range 0.1 Hz to 300 MHz Aux Parameters Period, pulse width Phase A Relative B, B Relative A Characteristic Description Range –180° to +360° Resolution Single cycle: 0.001° to 10 kHz, decreasing to 1° >10 MHz. Resolution can be improved by averaging (statistics) Frequency Range Up to 160 MHz Aux Parameters Freq (A), Va/Vb (in dB) Totalize A, B (FCA3100 Series) Characteristic Description Mode T o tA ,T o tB ,T o tA + B ,T o tA – B ,T o tA / B Range 1 to 10 10 counts Frequency Range Up to 160 MHz Start Control Manual, start arming Stop Control Manual, stop arming, timed Aux Parameters Other Totalize functions Vmax,V min,V p-p A, B Characteristic Description R a n g e – 5 0Vt o+ 5 0V ,– 5Vt o+ 5V Range is limited by the specification for max input voltage without damage (see input A, B) Frequency Range DC, 1 Hz to 300 MHz Mode V max,V min,V p-p Resolution 3 mV (FCA3000 Series) 1 mV (FCA3100 Series) Uncertainty (5 V range, typical) D C ,1H zt o1k H z 1 %+1 5m V 1k H zt o2 0M H z 3% + 15 mV 20 to 100 MHz 10% + 15 mV 1 0 0t o3 0 0M H z 30% + 15 mV Aux Parameters V min,V max,V p-p Time Stamping A, B, C Raw time-stamp data together with pulse counts on inputs A, B, or C, accessible through GPIB or USB only. Characteristic Description Max Sample Speed See GPIB speci fications Max Frequency 160 MHz Time-stamp Resolution 100 ps (FCA3000 Series) 50 ps (FCA3100 Series) Input and Output Specifications Inputs A and B Characteristic Description Frequency Range DC Coupled: DC to 300 MHz AC Coupled: 10 Hz to 300 MHz 300-400 MHz in Manual Trigger mode for both AC and DC Impedance 1M Ω/2 0p Fo r5 0Ω(VSWR ≤2:1) Trigger Slope Positive or negative Max Channel Timing Difference 500 ps Sensitivity 15 mV RMS (DC-200 MHz) 25 mVRMS (200-400 MHz) Attenuation X1, X10 Dynamic Range (X1) 30 mVp-p to 10 Vp-p within ±5 V window Trigger Level Readout on display Resolution FCA3000 Series: 3 mV FCA3100 Series: 1 mV Uncertainty (X1) ±(15 mV + 1% of trigger level) AUTO trigger level Trigger level is automatically set to 50% point of input signal (10% and 90% for rise/fall time) Auto Hysteresis Time Min hysteresis window (hysteresis compensation) Frequency One-third of input signal amplitude Frequency Range 1 Hz to 300 MHz Analog LP Filter Nominal 100 kHz, RC type Digital LP Filter 1H zt o5 0M H zc u t o f ff r e q u e n c y Max Voltage without Damage 1M Ω 350 V (DC + AC peak) to 440 Hz, falling to 12 VRMS (X1) at 1 MHz 50 Ω 12 VRMS (Unprotected Input) Connector BNC www.tektronix.com 5

Input C – 3 GHz (FCA3003 and FCA3103 Products) Characteristic Description Operating Input Voltage Range 1 0 0t o3 0 0M H z 2 0m VRMS to 12 VRMS 0.3 to 2.5 GHz 10 mVRMS to 12 VRMS 2.5 to 2.7 GHz 20 mVRMS to 12 VRMS 2.7 to 3.0 GHz 40 mVRMS to 12 VRMS Prescaler Factor 16 Impedance 50 Ωnominal, VSWR < 2.5:1 Max Voltage without Damage

12 VRMS, pin-diode protected

Input C – 20 GHz (FCA3020 and FCA3120 Products) Characteristic Description Frequency Range 0.25 to 20 GHz Operating Input Voltage Range 2 5 0t o5 0 0M H z – 2 1t o+ 2 7d B m 0 . 5t o1 4GHz –27 to +27 dBm 14 to 18 GHz –27 to +27 dBm 18 to 20 GHz –21 to +27 dBm Prescaler Factor 128 Impedance 50 Ωnominal, VSWR < 2.0:1 AM Tolerance >90% within sensitivity range Max Voltage without Damage +27 dBm Connector Type Precision-N Female Rear Panel Inputs and Outputs Characteristic Description Reference Input 1, 5, or 10 MHz; 0.1 to 5 V RMS sine; impedance≥1k Ω Reference Output 10 MHz; >1 V RMS sine into 50Ω Arming Input Arming of all measuring functions Impedance Approx. 1 kΩ Frequency range DC to 80 MHz Pulse Output (FCA3100 Series) Programmable through front GPIB/USB Mode Pulse Out, Gate Open, Alarm Out Period 20 ns - 2 s, in 10 ns increments Pulse width 10 ns - 2 s, in 10 ns increments Output TTL levels in 50 Ω,r i s et i m e2n s Rear-panel Measurement Inputs A, B, C (Option RP only) Impedance 1M Ω/5 0p Fo r5 0Ω(VSWR ≤2:1) Connectors SMA female for rear input C BNC for all other inputs/outputs Auxiliary Functions Trigger Holdoff Characteristic Description T i m eD e l a yR a n g e 2 0n st o2s ,1 0n sr e s o l u t i o n External Start and Stop Arming Characteristic Description Modes Start, Stop, Start and Stop Arming Input Channels A, B, or (rear panel) E Max Rep. Rate for Arming Signal Channel A, B 160 MHz Channel E 80 MHz Start-time Delay Range 20 ns to 2 s, 10 ns resolution Statistics Characteristic Description Functions Maximum, Minimum, Mean,ΔMax-Min, Standard Deviation, and Allan Deviation Display Numeric, histograms, or trend plots Sample Size 2t o2×1 09 samples Limit Qualifier Off, or capture values above, below, inside, or outside limits Measurement Pacing Pacing Time Range: 4 µs to 500 s Mathematics Characteristic Description Functions (K*X+L)/M and (K/X+L)/M. X is current reading and K, L, and M are constants; set using the keyboard or as frozen reference value (X Other Functions Characteristic Description Measuring Time 20 ns to 1000 s for frequency, burst, and period average. Single cycle for other measuring functions Time-base Reference Internal, external, or automatic Display Hold Freezes the result, un til a new measurement is initiated through a restart Limit Alarm Graphical indication on front panel and/or SRQ through GPIB, plus pulse output connector (FCA3100 Series) Limit Values Lower limit, upper limit Settings Off, or alarm if value is above, below, inside, or outside limits On Alarm Stop or Continue Display Numeric + Graphic Stored Instrument Setups 20. Instrument setups can be saved/recalled from internal nonvolatile memory. 10 can be user protected Display Backlit LCD graphics screen for menu control, numerical readout, and status information Number of digits 14 digits in Numerical mode Resolution 320 × 97 pixels GPIB Interface Characteristic Description Compatibility IEEE 488.2-1987, SCPI 199953131A Compatibility mode Interface Functions SH1, AH1, T6, L4, SR1, RL1, DC1, DT1, E2 Max Measurement Rate GPIB 15k/5k readings/s (Block mode) 4k/- readings/s (Talker Only mode) 650/500 readings/s (individual GET triggered) To internal memory 250k readings/s Internal Memory Size 750k readings (FCA3000 Series) 3.75M readings (FCA3100 Series) 6 www.tektronix.com

Timer/Counter/Analyzers — Tektronix FCA3000 and FCA3100 Series USB Interface Characteristic Description USB Version 2.0 full speed (11 Mb/s) Calibration Characteristic Description Mode Closed case, menu controlled Calibration Frequencies 0.1, 1, 5, 10, 1.544, and 2.048 MHz General Specifications Environmental Data Characteristic Description Class MIL-PRF-28800F, Class 3 Operating Temp 0 °C to +50 °C Storage Temp –40 °C to +71 °C Humidity 5-95% (10-30 °C) 5-75% (30-40 °C) 5-45% (40-50 °C) Altitude Operating: 2,000 m Storage: 12,000 m Safety Directive 2006/95/EC, EN61010-1, UL61010-1, CAN/CSA C22.2 No. 61010-1 EMC EU Directive 2004/108/EC, EN61326-1, EN61326-2-1, Class A Power Requirements Characteristic Description Basic Version 90 to 265 V RMS,4 5t o4 4 0H z ,< 4 0W Time-base Options Characteristic Standard Medium Stability (MS) High Stability (HS) Time-base Type TCXO OCXO OCXO Uncertainty Due to – Aging Temperature variation (typ. values) Short-term Stability: t = 1 s Not specified <1×10–10 <1×10–11 Root Allan Variance: t = 10 s Not specified <1×10–10 <1×10–11 Power-on Stability NA <1×10 –7 <1×10–8 Deviation versus final value after 24h ON time, after a warm-up time of: 30 min 30 min 10 min Total Uncertainty, for Operating Temperature 20 °C to 26 °C, at 2σ(95%) Confidence Interval 1y e a ra f t e r calibration 2 years after calibration *1 After 1 month of continuous operation. Physical Dimension mm in. Height 90 3.6 Width 210 8.25 Depth 395 15.6 Weight kg lb. Net 2.7 5.8 Shipping 3.5 7.5

Ordering Information

FCA3000 Timer/Counter/Analyzer 300 MHz / 100 ps FCA3003 Timer/Counter/Analyzer 3 GHz / 100 ps FCA3020 Timer/Counter/Analyzer 20 GHz / 100 ps FCA3100 Timer/Counter/Analyzer 300 MHz / 50 ps FCA3103 Timer/Counter/Analyzer 3 GHz / 50 ps FCA3120 Timer/Counter/Analyzer 20 GHz / 50 ps FCA3000/3100 Series Include: Timer/Counter, line cord, calibration certificate, Quick Start User Manual, CD-ROM with user manual (English, French, German, Spanish, Simplified Chinese, Traditional Chinese, Korean, Russian, Japanese), Programmer's Guide, Technical Specifications, Trial version of TimeView™ Software, and CD-ROM with National Instruments LabVIEW SignalExpress™ Tektronix Edition, Limited Edition Software. Note: Please specify power plug when ordering. Instrument Options Option Description MS Medium-stability Oven Time Base HS High-stability Oven Time Base RP Rear-panel Connectors Power Plug Options Option Description A0 North America A1 Universal Euro A2 United Kingdom A3 Australia A5 Switzerland A6 Japan A10 China A11 India A12 Brazil E1 UK and Euro (FCA3000 and FCA3100 only) www.tektronix.com 7

Datasheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries+41 52 675 3777 Belgium 00800 2255 4835* Brazil + 5 5( 1 1 )3 7 5 97 6 2 7 Canada 1 800 833 9200 Central East Europe and the Baltics+ 4 15 26 7 53 7 7 7 Central Europe & Greece+41 52 675 3777 Denmark + 4 58 08 81 4 0 1 Finland + 4 15 2675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg + 4 15 26 7 53 7 7 7 Mexico, Central/South America & Caribbean52 (55) 56 04 50 90 Middle East,Asia, and North Africa+41 52 675 3777 The Netherlands00800 2255 4835* Norway 800 16098 People’s Republic of China400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic ofKorea 001 800 8255 2835 Russia & CIS+7 (495) 7484900 South Africa+ 4 15 26 7 53 7 7 7 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 February 2011 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visitwww.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.

25 Jul 2012 3CW-25556-4

C3 Calibration S e r v i c e3Y e a r s C5 Calibration S e r v i c e5Y e a r s D1 Calibration Data Report R5 Repair Service 5 Years SILV200 Standard Warranty Extended to 5 Years (FCA3000, FCA3003, FCA3100, and FCA3103) SILV400 Standard Warranty Extended to 5 Years (FCA3020 and FCA3120) Recommended Accessories and Software Accessory Description RMU2U Rackmount Shelf Kit for 2 Units HCTEK4321 Hard Carrying Case ACD4000 Soft Carrying Case 174-4401-xx USB Host to Device Cable, 3 ft. 012-0991-xx GPIB Cable, Double Shielded 012-1256-xx BNC Male to BNC Male, Cable Shielded, 9 ft., 50Ω 012-0482-xx BNC Male to BNC Male, Cable Shielded, 3 ft., 50Ω SIGEXPTE National Instruments SignalExpress™ Tektronix Edition Interactive MeasurementSoftware – Professional Version TVA3000 TimeView™ Modulation Domain Analysis Software Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. www.tektronix.com