FA39 LUMEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
www.lumel.com.pl Fa39, Fa32 PANEL POWER FACTOR METERS 103,6 mm 92 +0,8mm103.6 mm 92 +0.8mm with built-in trandsucers APPLICATION FA39 and FA32 panel power factor meters are destined for measurements of the phase angle between the voltage and current in single-phase or three-phase AC power networks. These meters are calibrated to correspond to the cosine of the angle, i.e. the power factor. These meters can be mounted on panels of any kind of materials. TECHNICAL DATA Input voltage (one of the series): - for single-phase meters 60, 100, 110, 230, 400 V - for meters working in symmetrically loaded 100, 110, 230, 400, 415, three-phase networks 440, 500 V Input current 1 A or 5 A Accuracy class 1.5 Rated operating conditions: - air relative humidity 25...85% - input voltage Un 15% - frequency of the input voltage 49...51 Hz for 1 phase 45...65 Hz for 3 phases - working position acc. order 5° (table 1) Additional errors acc. EN 60051-1 standard Power consumption - in voltage circuit 8 VA - in current circuit 0.2 VA Protection Grade acc. to EN60529 - front protection grade: - IP52 - IP65 only for F39 meters - terminal protection: IP20 Electromagnetic compatibility: The meter fulfils CE mark requirements: - emission acc. EN 61000-6-4 standard - immunity acc. EN 61000-6-2 standard Safety requirements - installation category III - level of polution 2 - maximal working voltage in relation to the earth 660 V METER SEAL GLASS Housing material thermoplastic, self-extinguishing plastic (UL 94V-O) Glass material glass (in standard) anti-reflective glass on request ACCESSORIES We deliver with the meter: EXTERNAL DIMENSIONS OF FA39 FOR IP65 PROTEC- TION GRADE
www.lumel.com.pl Type a c d e f k mm FA39 96 92+0.8 5,5 51.5 63.5 92+0.8 FA32 144 138+1.0 5,5 53 63.5 138+1.0 f ed SPOSÓB MOCOWANIA W TABLICY WORkING POSITION Code Working position 0 c3 A c1 B c2 = 15° C c2 = 30° D c2 = 45° E c2 = 60° F c2 = 75° H c4 = 105° I c4 = 120° Table 1 EXTERNAL DIMENSIONS OF F32 AND FA39 FOR IP52 PROTECTION GRADE Fig. 2. Fixing of meters FA39 in the panel (version with IP52) 1 Fig. 3. Fixing of FA32 meters (version with IP52)2
1 Included are two screw holders which should be fixed on
arbitrary, opposite case corners 2The meter is fixed to the panel by two screw holders situated on opposite corners of the case.
www.lumel.com.pl ELECTRICAL CONNECTIONS OF EXTERNAL CIRCUITS X X X k LK I LF 72/96 three phase three wire balanced load LF 72/96 Single phase 17 18 15 16 K I X k L N(L2) 17 18 15 16 Connections a x a1 2 I x I1 2 h t f Dimensions X X X k LK I LF 72/96 three phase three wire balanced load LF 72/96 Single phase 17 18 15 16 K I X k L N(L2) 17 18 15 16 Connections a x a1 2 I x I1 2 h t f Dimensions single phase thre phase wire balanced load POWER FACTOR METERS FA39, FA32 X X X XX X XX X Measurement of power factor in: Measuring range: Input current: Input voltage: Working position Version: Acceptance tests: EXAMPlE OF ORDER Code: FA39-1-A-5-04-O-00-8, means: input voltage: 230 V, working position: c3 (90° - vertical), standard version, without additional test requirements. ORDERING PROCEDURE FA39-19_en Export department: tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386 fax.: (+48 68) 32 54 091 e-mail: export@lumel.com.pl LUMEL S.a. ul. Sulechowska 1, 65-022 Zielona Góra, POLAND tel.: +48 68 45 75 100, fax +48 68 45 75 508 www.lumel.com.pl