EDS1417-001 EUROPA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Europa Components, Europa House, Airport Way, Luton, Beds, LU2 9NH Technical: 01582 692 444 | technical@europacomponents.com Sales: 01582 692 440 | sales@europacomponents.com Website: www.europacomponents.com It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS EDS1417-001 Part Number: EUR1100 RCCB TYPE ‘A’ 100A 2 & 4 Pole for TPN BOARDS Features & Benefits

  • Can be fitted upstream of a Type A or Type AC device.
  • Type A is also suitable for Type AC applications resulting to a wider range of installations which the RCCB can be used in.
  • Suitable for electric vehicle charging where any smooth DC fault current is less than 6mA. Product Range EUR1 Standard(s) BS EN 61008-1, EN 61008-1 Type A Declaration and Approval UKCA & CE Rated Current (In) 100A Rated Residual Operating Current IΔn 30, 100 & 300mA Tripping Time 1 x IΔn ≤ 300ms | ≤ 500ms (Time Delay) Tripping Time 5 x IΔn ≤ 40ms | ≤ 150ms (Time Delay) Rated Voltage (Ue) AC 230(240) / 400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 / 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -25° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.6-35mm² Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period. Note: Type A is suitable for Type AC applcations. Type A is suitable where any smooth DC fault current is less than 6mA.

Examples: 100A 2 Pole 30mA Type A >> EUR1100.30/2A 100A 4 Pole 100mA Type A >> EUR1100.100/4A 100A 4 Pole 300mA Type A >> EUR1100.300/4A 100A 4 Pole 100mA Time Delay Type A >> EUR1100.100/4SA Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

2 Pole 10kA RCD

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail

4 Pole 10kA RCD

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

2 Pole 4 Pole

RCCB_EDS1067.indd 1 16/11/2017 14:30 Dimensions E / mA Rating 30, 100 or 300 Number of Poles: 2 or 4 100A RCCB Range Prefix U R 1 . Type A RCCB A Time Delay (100mA Only) Leave Blank for no Time Delay 1 0 0 S Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationCE & SEMKO Rated Current (In)80 & 100A Rated Residual Operating Current IΔn30mA & 100mA Standard Tripping Time 1 x IΔn≤ 500ms Standard Tripping Time 5 x IΔn≤ 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 366

  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240) Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles2 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR14 Pole 10kA ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm

2 Pole4 Pole

RCCB_EDS1067.indd 116/11/2017 14:30 Page 1 of 1EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationCE & SEMKO Rated Current (In)80 & 100A Rated Residual Operating Current IΔn30mA & 100mA Standard Tripping Time 1 x IΔn≤ 500ms Standard Tripping Time 5 x IΔn≤ 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 366

  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240) Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles2 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR14 Pole 10kA ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm

RCCB_EDS1067.indd 116/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1 EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification CE & SEMKO Rated Current (In) 80 & 100A Rated Residual Operating Current IΔn 30mA & 100mA Standard Tripping Time 1 x IΔn ≤ 500ms Standard Tripping Time 5 x IΔn ≤ 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 36 6

  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240) Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR1 4 Pole 10kA Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product Range EUR1 Standard(s) IEC 61008, EN 61008 Type AC Certification SEMKO Rated Current (In) 25, 40, 63, 80A Rated Residual Operating Current IΔn 30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Time Delay Tripping Time 1 x IΔn 130 - 500ms Time Delay Tripping Time 5 x IΔn 50 - 150ms Rated Voltage (Ue) AC 230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² Recommended Terminal Torque 2.0Nm

RCCB_EDS1067.indd 1 16/11/2017 14:30 Page 1 of 1EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationCE & SEMKO Rated Current (In)80 & 100A Rated Residual Operating Current IΔn30mA & 100mA Standard Tripping Time 1 x IΔn≤ 500ms Standard Tripping Time 5 x IΔn≤ 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 366

  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240) Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles2 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR14 Pole 10kA ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm

RCCB_EDS1067.indd 116/11/2017 14:30 Page 1 of 1EDS1273-001 Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com website: http://www.europacomponents.com Technical Data: 100mA Time Delay RCCB EUR1 2 & 4 Pole 10kA Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationCE & SEMKO Rated Current (In)80 & 100A Rated Residual Operating Current IΔn30mA & 100mA Standard Tripping Time 1 x IΔn≤ 500ms Standard Tripping Time 5 x IΔn≤ 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² (80A) 1.5-35mm² (100A) Recommended Terminal Torque2.0Nm * Average not exceeding 35°C over a 24 hour period Page 1 of 1 EDS1067-002 ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com 366

  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240) Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles2 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm Technical Data: RCCB EUR1 2 Pole 10kA It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. Important Safety Notice DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 1 EDS1068-002 Technical Data: RCCB EUR14 Pole 10kA ImportantSafety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Important Europa House, Airport Way, Luton, Beds, LU2 9NH Tel: 01582 692 440 / Fax: 01582 692 450 e-mail: sales@europacomponents.com / website: http://www.europacomponents.com Terminal height from DIN rail
  • average not exceeding 35°C over a 24 hour period Product RangeEUR1 Standard(s)IEC 61008, EN 61008 TypeAC CertificationSEMKO Rated Current (In)25, 40, 63, 80A Rated Residual Operating Current IΔn30mA, 100mA & 100mA Time Delay Standard Tripping Time 1 x IΔn≤ 300ms Standard Tripping Time 5 x IΔn≤ 40ms Time Delay Tripping Time 1 x IΔn130 - 500ms Time Delay Tripping Time 5 x IΔn50 - 150ms Rated Voltage (Ue)AC 230(240)/400(415)V Rated Frequency50/60Hz Rated impulse withstand Voltage (Uimp)4kV Number of Poles4 Rated Short-Circuit Capacity (Inc)10kA Operating Temperature-5° to 40°C* AltitudeNot exceeding 2000 metres HumidityNot exceeding 50% at 40°C and 90% at 20°C Pollution Degree2 Terminal protectionIP20 Mounting35mm DIN Rail Terminal TypeTunnel Terminal Capacity1.5-25mm² Recommended Terminal Torque2.0Nm

RCCB_EDS1067.indd 116/11/2017 14:30 Page 1 of 2 EDS1257-002 Technical Data: RCBO EUBLMC 2 Pole 6kA Type AC A Product Range EUBLMC Standard(s) IEC 61009, EN 61009 Certification CE, SEMKO Characteristic Curve B, C C Rated Current (In) 6, 16, 20, 32 & 40A 16, 32, 40A Rated Residual Operating Current IΔn 30mA Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Rated Voltage (Ue) AC 230(240)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Icn) 10kA Operating Temperature -25° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Pillar Terminal Capacity 1.0-16mm² Recommended Terminal Torque 2.0Nm * average not exceeding 35°C over a 24 hour period Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Note: Type A is suitable for Type AC applications. Type A is suitable where any smooth DC fault current is less than 6mA