EDS1378-002 EUROPA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Europa Components, Europa House, Airport Way, Luton, Beds, LU2 9NH Technical: 01582 692 444 | technical@europacomponents.com Sales: 01582 692 440 | sales@europacomponents.com Website: www.europacomponents.com It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS EDS1378-002 Part Number: EUR1 RCCB TYPE ‘A’ 10kA Features & Benefits

  • Can be fitted upstream of a Type A or Type AC device.
  • Type A is also suitable for Type AC applications resulting to a wider range of installations which the RCBO can be used in.
  • Suitable for electric vehicle charging where any smooth DC fault current is less than 6mA. Product Range EUR1 Standard(s) BS EN 61008, EN 61008 Type A Declaration and Approval UKCA, CE & SEMKO* Rated Current (In) 25 / 40 / 63 / 80 / 100A Rated Residual Operating Current IΔn 30 / 100 / 300mA Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Rated Voltage (Ue) AC 110/230(240)/400(415)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 / 3 / 4 Rated Short-Circuit Capacity (Inc) 10kA Operating Temperature -5° to 40°C** Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 1.5-25mm² (25A, 40A, 63A, 80A) 1.5-35mm² (100A) Recommended Terminal Torque 2.0Nm *Not including 3 Pole RCCBs and 110V RCCBs. ** Average not exceeding 35°C over a 24 hour period. Note: Type A RCCB is suitable for Type AC applications and for installations where any smooth DC fault current is less than 6mA.

Examples: 40A 2 Pole 30mA Type A 230V >> EUR140.30/2A 63A 4 Pole 100mA Type A 400V >> EUR163.100/4A 80A 2 Pole 30mA Type A 110V >> EUR180.30/2A/110V 100A 4 Pole 30mA Type A 400V >> EUR1100.30/4ACU Dimensions E / AC Rated Voltage 110V Leave Blank for AC 230V / 400V Rated Amperage 25, 40, 63, 80 or 100 mA Rating 30, 100 or 300 (80A only) Number of Poles: 2, 3 or 4 RCCB Range Prefix U R 1 . A / V Type A RCCB Only for 100A variants EUR1100.30/2ACU EUR1100.30/4ACU

2 Pole 3 Pole 4 Pole

EUR1 /2 EUR1 /4 EUB1RC.6/1B EUR125.30/2B EUR125.30/4BEUBAFD40C30 EUBLMC6C30EUC7R.6/1B Page 1 of 2 EDS1257-002 Technical Data: RCBO EUBLMC 2 Pole 6kA Type AC A Product Range EUBLMC Standard(s) IEC 61009, EN 61009 Certification CE, SEMKO Characteristic Curve B, C C Rated Current (In) 6, 16, 20, 32 & 40A 16, 32, 40A Rated Residual Operating Current IΔn 30mA Standard Tripping Time 1 x IΔn ≤ 300ms Standard Tripping Time 5 x IΔn ≤ 40ms Rated Voltage (Ue) AC 230(240)V Rated Frequency 50/60Hz Rated impulse withstand Voltage (Uimp) 4kV Number of Poles 2 Rated Short-Circuit Capacity (Icn) 10kA Operating Temperature -25° to 40°C* Altitude Not exceeding 2000 metres Humidity Not exceeding 50% at 40°C and 90% at 20°C Pollution Degree 2 Terminal protection IP20 Mounting 35mm DIN Rail Terminal Type Pillar Terminal Capacity 1.0-16mm² Recommended Terminal Torque 2.0Nm * average not exceeding 35°C over a 24 hour period Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be checked periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Note: Type A is suitable for Type AC applications. Type A is suitable where any smooth DC fault current is less than 6mA