This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Page 1 of 2 EUR PA Smart Solutions, Switched on ServiceSmart Solutions, Switched on Service Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com | www.europa-plc.com Data Sheet EDS1339-002 Arc Fault Detection Devices with Integrated Type A RCBO | AFDD

  • BS EN 62606, BS EN 61009-1
  • Rated Voltage Ue 230V AC | Rated Frequency 50/60Hz
  • Rated T ripping Current l Δn 30mA
  • Rated Non-T ripping Current l Δno 0.5l Δn
  • Sensitivity Class 3
  • Rated peak withstand voltage Uimp 4kV
  • Electrical Endurance ≥ 4,000 switching operations
  • Mechanical Endurance ≥ 10,000 switching operations
  • Recommended T erminal T orque (In) 2.0 Nm | (Out) 1.2 Nm
  • T erminal Capacity (In) 16 mm2 | T erminal Capacity (Out) 10 mm2
  • Operating T emperature -25°C to +40°C Part Number B Curve Description EUBAFD6B30 6kA 6A 30mA B Curve Type A EUBAFD10B30 6kA 10A 30mA B Curve Type A EUBAFD16B30 6kA 16A 30mA B Curve Type A EUBAFD20B30 6kA 20A 30mA B Curve Type A EUBAFD25B30 6kA 25A 30mA B Curve Type A EUBAFD32B30 6kA 32A 30mA B Curve Type A EUBAFD40B30 6kA 40A 30mA B Curve Type A i Detects electrical arcing faults that MCBs, RCCBs and RCBOs cannot detect. i Type A device suitable for use on AC and pulsating DC circuits. ATTENTION: Disconnect both line and neutral and flying lead before carrying out insulation test. Part Number C Curve Description EUBAFD6C30 6kA 6A 30mA C Curve Type A EUBAFD10C30 6kA 10A 30mA C Curve Type A EUBAFD16C30 6kA 16A 30mA C Curve Type A EUBAFD20C30 6kA 20A 30mA C Curve Type A EUBAFD25C30 6kA 25A 30mA C Curve Type A EUBAFD32C30 6kA 32A 30mA C Curve Type A EUBAFD40C30 6kA 40A 30mA C Curve Type A Width: 18mm Height: 115mm Depth: 78mm

Smart Solutions, Switched on ServiceSmart Solutions, Switched on Service Fault Protection Fault type Detected by integrated Short circuit RCBO Overload RCBO Residual current RCBO Series arcing fault AFD Parallel arcing fault AFD Parallel arcing fault to PE RCBO LED indication after tripping and re-closing Description of fault cause RCBO overcurrent fault or Residual current fault Series arcing fault or Parallel arcing fault Overvoltage fault (U>275Vac) AFDD internal self-test fault AFDD LED Indicator | After T ripping Steady red light 1 blink / sec (total 10 sec) 2 blinks / sec (total 10 sec) 5 blinks / sec (continuous blinking) Series Arcing Fault Load current (A) Max allowed tripping time (s) 2.5 1 5 0.5 10 0.25 16 0.15 32 0.12 40 0.12 AFDD Operating Criteria | According to BS EN 62606 Parallel Arcing Fault Test current (A) Max allowed number of arcing half-waves within 0.5s(N) 75 12 100 10 150 8 200 8 300 8 500 8