Features
z No external parts, High reliability z Small size package z Photo detector and preamplifier in one package z Inner shield, good anti-interference ab ility z High sensitivity, large transmission range z TTL and CMOS compatibility
Applications
z AV instruments (Audio, TV, VCR, CD player) z Home appliances (Air-conditioner, Fan, Light) z Remote control for wireless devices Maximum Ratings (Ta =25℃) z Supply Voltage 3 – 6Volt z Junction Temperature 100℃ z Operating Temperature -25 ~ +85℃ z Storage Temperature -25 ~ +85℃ z Soldering Temperature 240℃ Optoelectric Characteristics (Ta =25℃, VS=5V) Parameter Symbol Min. Typ. Max. Unit Supply Voltage VCC 3.0 6.0 V Supply Current I CC 2.5 5 mA Peak Sensitivity Wavelength λP 940 nm Modulated Frequency f o 37.9 KH Z High Level Output Voltage V OH 4.2 5.0 V Low Level Output Voltage V OL 0.2 0.25 V High Level Output Pulse Width T wh 540 600 660 µS Low Level Output Pulse Width T wl 540 600 660 µS Receiving Distance L 15 m Controlled Angle Δθ ±55 deg Dimension in mm
Flat 2505, 25/F., Nanyang Plaza, 57 Hung To Road, Kwun Tong, H.K. Tel: (852) 2723-3122 Fax: (852) 2723-3990 Email: info@elite-ent.com.hk Page: 2 / 5 Recommended application circuit : Frequency Dependence of Responsibility : Directivity : Relative responsibility f = fo ± 5% ∆f (3dB) = fo / 10 Relative frequency Angle Relative transmission distance . / DEG 100 (Ee min / Ee) / % 100 -90 -60 -30 0 30 60 90 Drel / %
Flat 2505, 25/F., Nanyang Plaza, 57 Hung To Road, Kwun Tong, H.K. Tel: (852) 2723-3122 Fax: (852) 2723-3990 Email: info@elite-ent.com.hk Page: 3 / 5 Note 1.Distance between emitter & detector specifies maximum distance that output form satisfies the standard (3-2) under the conditions below the standard transmitter (1) Measuring place … Indoor without extreme reflector of light (2) Ambient light source … Detecting surface lamination shall be 200 ± 50Lux under ordinary white fluorescence lamp or high frequency lightning (3) Standard transmitter … Burst wave indicated in drawing 3-1 of Standard transmitter shall be to 50mVp-p under the measuring circuit specified in drawing 3-2 BLOCK DIAGRAM STANDARD TRANSMITTER
Flat 2505, 25/F., Nanyang Plaza, 57 Hung To Road, Kwun Tong, H.K. Tel: (852) 2723-3122 Fax: (852) 2723-3990 Email: info@elite-ent.com.hk Page: 4 / 5 4. Reliability TEST ITEM TEST CONDITION STANDARD High Temperature Ta=+60℃ V cc=5.0V t=240H Note 2. High Temp. & High Hum. Ta=+40℃ 90%RH V cc=5.0V t=240H Note 2. Low Temperature T a=-10 V cc=5.0V t=240H Note 2. Heat Cycle -20(0.5H) ∼ +75(0.5H) 20Cycle Note 2. Dropping Test devices shall Be dropper 3 times naturally onto hard wooden board from a 75cm position Note 3. Note 2. 3-2 (electro-optical characteristics) s hall be satisfied after leaving 2 hours in the normal temperature. Note 3. 3-2 (electro-optical characteristics) shall be satisfied and no conditions deforms and destruction of appearance. (excepting deforms of terminals) 5. Inspection standard 5-1. Among electrical characteristics to tal number shall be inspected on items blow 1. Front distance between emitter & detector inspection standard 2. Current consumption 3. H level output voltage 4. L level output voltage 5-2. Items except above mentioned are not inspected particularly, but shall fully satisfy 6. Caution (When use and storage of this device) 6-1. Store and use where there is no force causing transformation or change in quality. 6-2. Store and use where there is no corrosive gas or sea (salt) breeze. 6-3. Store and use where there is no extreme humidity. 6-4. Solder the lead-pin within the condition of ratings. After solder do not add exteriors force. 6-5. Do not wash this device wipe the stains of diode side with a soft cloth you can use the solvent ethyl alcohol or isopropyl one only. 6-6. To prevent static electricity damage to the Pre-AMP, make sure that the human body, the soldering iron is connected to ground before using. 6-7. Put decoupling device between V cc and GND for reduce the noise from power supply line. 6-8. The performance of remote-control system depends on environments condition and ab ility of peripheral parts, Customer should evaluate the performance as total system in those conditions after system up with components such as commander, micon and this receiver
Flat 2505, 25/F., Nanyang Plaza, 57 Hung To Road, Kwun Tong, H.K. Tel: (852) 2723-3122 Fax: (852) 2723-3990 Email: info@elite-ent.com.hk Page: 5 / 5 module. 6-9. Connect the shield case on the base pattern. 7. Guarantee period and scope 7-1. Guarantee period One year after delivery to desired place. 7-2. Guarantee scope A re-delivery of goods w ill be carried out if the cause of malfunction lies in our devices, However no responsibilities will be taken the inconveniences caused by the malfunction of our devices. 8. Others 8-1. This devices is not design to endure radioactive rays and heavily charged particles. 8-2. In case where any trouble questions aris e, both parties agree to make full discussion covering the said problem.