Technical content
This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should also be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1304-002 Page 1 of 2 EUR PA ECSS-101 Safe Surge Unit TY630N According the IEC61643-11 Type 2 Earthing System TT/TN System Voltage Un 230/400V Max. continous operation AC voltage Uc 275V Norminal discharge current (8/20µs) In 15kA Maximum discharge current (8/20µs) Imax 30kA Voltage protection level Up 1.5kV Maximum backup fuse (gL) / MCB 63A Response time IA 25ns Status indicator non/red Mounting 35mm Din Rail Cross section of wire (min.) 4mm Cross section of wire (max.) 16mm Casing material Thermal plastic UL94 - V0 Degree of protection IP20 SPD Specification Product Ranges ISO100-2 Standard (s) IEC 60947-3, EN 60947-3 Rated Current (In) 100A Rated Uninterupted Current (Iu) 100A Rated Operational Voltage (Ue) AC 230 (240) / 400 (415)V Rated Frequency 50/60Hz Rated impulse withstand voltage (Uimp) 6kV Number of poles 2 Rated Insulation Voltage (Ui) 500V Utilization Category AC-22B Operating Temperature -5̊ to 40 ̊C* Altitude Not exceeding at 2000 metres Humidity Not exceeding 50% at 40 ̊C and 90% at 20 ̊C Pollution Degree 3 Terminal Protection IP20 Mounting 35mm DIN Rail Terminal Type Tunnel Terminal Capacity 2.5-35mm² Recommended Terminal Torque 2.0Nm Isolator Specification Enclosure Dimensions NOTE: SPD Status Indicator = Red - Replace
Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1304-002 Page 2 of 2 EUR PA ECSS-101 Installation The ECSS-101 surge protection device is designed to be installed directly from from a spare way in the consumer unit using 6mm cable. Short circuit protection should be provided by a 32A ‘C’ curve MCB. The combined length of the connecting conductors in relation to the current path should ideally be less than 0.5 Metres and in no circumstances exceed 1 Metre. Live + CPC = <0.5M (Maximum 1M) Neutral + CPC = <0.5M (Maximum 1M)