Triple output bench power supply Power Your Next Insight For more than 50 years, Keysight Technologies, Inc. DC power supplies have been changing the way engineers prove their design, understand the issues, and ensure product quality. On the bench, the triple- output E36300 series is ready for your application. With low output ripple/noise and accurate voltage/current measurement, you can test with confidence—and power your next insight.
The triple output E36300 Series gives you the performance of system power supplies at an affordable price. There are three models available in the series: E36311A: This 80 W model offers a simplified user experience and the lowest price of the series. Some of the key differences include channels 2 and 3 are configured in tracking mode only, USB interface only, 2-wire sensing. This model does not offer data logging, output sequencing, list mode and auto parallel/serial voltage or current boost. E36312A: This 80 W model offers the complete feature set. Channel 2 and 3 are electrically isolated independent channels. Some of the key extended features include USB, LAN and optional GPIB interface, 2 or 4-wire sensing, data logging, output sequencing, list mode, and auto parallel/serial. E36313A: This 160 W model offers twice the current of the other models with the same extended feature set as the E36312A model.
Features
Clean, reliable power
- Low output ripple and noise
- Excellent programming/readback accuracy
- Excellent line/load regulation: 0.01%
- 2-wire or 4-wire remote sense
- Over voltage, over current, and over temperature protection Intuitive and easy to use interfaces
- 4.3-inch LCD color display
- Color-coded channels
- Individual knobs for voltage and current
- E3631A code compatible
- LAN (LXI), USB and GPIB (optional) Convenient benchtop capabilities
- Three independent power supplies in one box
- Low acoustic noise
- Auto series/parallel connections
- Front and rear output terminal Advance characterization
- Data logging
- Output sequencing
- LIST mode
- Low current range measurement E36311A 80W Triple Output Power Supply, 6V, 5A & ±25V, 1A, USB E36312A 80W Triple Output Power Supply, 6V, 5A & 2X 25V, 1A, USB, LAN E36313A 160W Triple Output Power Supply, 6V, 10A & 2X 25V, 2A, USB, LAN
(< 20 mA) reduces the need for an external multimeter and simplifies the setup. commonly found on other bench power sources. Figure 1. On E36312A or E36313A set 2-wire or 4-wire sensing for output 1 in just one click
the bench as you can power up multiple analog/digital circuitries or devices with a single instrument. mode on the front panel to double the output voltage (up to 50 V) or current (up to 4 A) respectively. condition, it allows you to work in a quiet and undisturbed environment. Figure 2. Auto-series operation to double the output voltage The 4.3-inch LCD color display shows the voltage and current of all three channels with different views. quick adjustments and configurations in less time.
success. The E36312/13A offer additional capabilities for emulating and analyzing power behaviors. in battery backup real time clock allows for proper timestamping of logged data. Figure 7. In Data Logger View, you can log data on multiple traces. Here the voltage of output 1, output 2 and output
Figure 8. Output sequencing and Output LIST mode setting
BenchVue Control and Visualization BenchVue software for the PC makes it simple to connect, control, and view Keysight power supplies simultaneously with other Keysight bench instruments without programming.
- Visualize the output of multiple power supplies simultaneously
- Log data, capture screen shots, and save a system state
- Recall a past state of your bench to replicate results
- Export measurement data in desired format fast
- Quickly access manuals, drivers, FAQs and videos
- Monitor and control your bench from mobile devices BenchVue software application
Which Model Is for You? There are three models in the E36300 Series. The chart below compares the features set available in each model. Feature E36311A 80 W Economy Model E36312A 80 W Full-Featured Model E36313A 160 W High Current Model Channels Tracking Only Fully Independent Fully Independent Electrically isolated channels Not available Standard Standard Remote Sensing 2 Wire Only 2 and 4-Wire 2 and 4-Wire Auto series/parallel Not available Standard Standard Data Logging Not available Standard Standard Output Sequencing Not available Standard Standard List Mode Not available Standard Standard USB port for data logging/storage Not available Standard Standard Digital triggers Not available Standard Standard Rear output terminals Not available Standard Standard Earth ground reference at rear panel Not available Standard Standard Digital I/O port Not available Standard Standard Connectivity USB USB and LAN Standard, GPIB Optional USB and LAN Standard, GPIB Optional Recessed binding posts Optional Optional Optional Keypad locking Standard Standard Standard Benchtop lock Standard Standard Standard
Specifications E36311A E36312A E36313A Power output 80 W 80 W 160 W DC output rating (0 to 40 ºC) 1 2 3 1 2 3 1 2 3 0 to 6 V 0 to +25 V 0 to -25 V 0 to 6 V 0 to 25 V 0 to 25 V 0 to 6 V 0 to 25 V 0 to 25 V 0 to 5 A 0 to 1 A 0 to 1 A 0 to 5 A 0 to 1 A 0 to 1 A 0 to 10 A 0 to 2 A 0 to 2 A Series mode voltage 2 NA 50 V 50 V Parallel mode current 2 NA 2A 4A Load regulation ± (% of output + offset) Voltage < 0.01% +2 mV < 0.01% +2 mV < 0.01% +4 mV Current < 0.01% +250 µA < 0.01% +250 µA < 0.01% +500 µA Line regulation ± (% of output + offset) Voltage < 0.01% +1 mV < 0.01% +1 mV < 0.01% +1 mV Current < 0.01% +250 µA < 0.01% +250 µA < 0.01% +500 µA Output ripple and noise (20 Hz to 20 MHz) Normal mode voltage < 350 µVrms / 2 mVpp < 350 µVrms / 2 mVpp < 350 µVrms / 2 mVpp < 1 mVrms / 5 mVpp Accuracy 12 months (23 ºC ± 5 ºC) Programming accuracy ± (% of output + offset) Voltage 0.1% +5 mV 0.05% +20 mV 0.03% +3 mV 0.03% +5 mV Current 0.1% +4 mA 0.04% +3 mA Readback accuracy ± (% of output + offset) Voltage 0.1% +5 mV 0.05% +10 mV 0.04% +3 mV 0.03% +5 mV Current 0.1% +5 mA 0.04% +3 mA Low range current 1 NA 0.25% +80 µA 0.25% +80 µA Load transient recovery time (Time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load) Voltage settling band 15 mV 15 mV 15 mV 30 mV 15 mV Voltage settling band (parallel mode) NA 30 mV 30 mV Time < 50 µS 1. 20mA for CH1, 10mA for CH2 and CH3. Tested at constant voltage mode. 2. All specifications are not applicable during auto series/parallel mode .
characteristics E36311A E36312A E36313A
80 W 80 W 160 W
Voltage 0.5 mV 1.5 mV 0.24 mV 1 mV 0.24 mV 1 mV Current 0.5 mA 0.1 mA 0.2 mA 160 µA 80 µA 0.2 mA 320 µA 160 µA Low range current 1 NA 10 µA 3 µA 2 µA 10 µA 3 µA 2 µA Programming front panel Voltage 1 mV 1 mV 1 mV Current 1 mA 1 mA 1 mA Readback front panel Voltage 1 mV 10 mV 1 mV 1 mV Current 1 mA 1 mA 1 mA Low range current 1 NA 10 µA 3 µA 2 µA 10 µA 3 µA 2 µA Output ripple and noise (20 Hz to 20 MHz) Normal mode current < 2 mArms < 500 µArms < 2 mArms 1 mArms 500 µArms < 4 mArms 2 mArms 1 mArms Overvoltage protection (OVP) ± (% of output + offset) Programming accuracy 0.20% Activation time (average time for the output to start to drop after OVP or OCP condition occurs) Overvoltage (OVP) < 5 ms Overcurrent (OCP) < 5 ms Command processing time < 10 ms Programming temperature coefficient per ºC (% of output + offset) Voltage 0.01% Current 0.02% +0.25 mA 0.01% +0.2 mA 0.01% +0.1 mA 0.01% +0.5 mA 0.01% +0.4 mA 0.01% +0.2 mA Readback temperature coefficient per ºC (% of output + offset) Voltage NA 0.01% +20 µV 0.01% +40 µV 0.01% +20 µV 0.01% +40 µV Current NA 0.01% +0.25 mA 0.01% +0.2 mA 0.01% +0.1 mA 0.01% +0.5 mA 0.01% +0.4 mA 0.01% +0.2 mA 1. 20 mA for CH1, 10 mA for CH2 and CH3.
characteristics E36311A E36312A E36313A Remote sense (max. voltage in load lead) NA 1 V 1 V Up/down programming settling time to within 1% of total excursion Up Full Load 11 msec 50 msec 11 msec 50 msec 15 msec 50 msec Up No load 10 msec 20 msec 10 msec 20 msec 15 msec 20 msec Down Full load 13 msec 45 msec 13 msec 45 msec 13 msec 45 msec Down No load 200 msec 400 msec 100 msec 150 msec 100 msec 400 msec Connectivity USB USB/LAN Opt-GPIB USB/LAN Opt-GPIB Typical Characteristics Interface capabilities
- GPIB SCPI – 1999, IEEE 488.2 compliant interface
- LXI compliance Class C
- USB 2.0 Requires Keysight IO Library version 17.2.208 and up
- 10/100 LAN Requires Keysight IO Library version 17.2.208 and up Digital control characteristics Digital control characteristics Maximum voltage ratings +16.5 VDC/−5 VDC between pins (pin 4 is internally connected to chassis ground) Pins 1 and 2 as Fault output Maximum low-level output voltage = 0.5 V @ 4 mA Maximum low-level sink current = 4 mA Typical high-level leakage current = 1 mA @ 16.5 VDC Pins 1 - 3 as digital/trigger outputs (pin 4 = common) Maximum low-level output voltage = 0.5 V @ 4 mA; 1 V @ 50 mA ; 1.75 V @ 100 mA Maximum low-level sink current = 100 mA Typical high-level leakage current = 0.8 mA @ 16.5 VDC Pins 1 - 3 as digital/trigger inputs and pin 3 as inhibit input (pin 4 = common) Maximum low-level input voltage = 0.8 V Minimum high-level input voltage = 2 V Typical low-level current = 2 mA @ 0 V (internal 2.2 k pull -up) Typical high-level leakage current = 0.12 mA @ 16.5 VDC
Operating environment Indoor use, installation category II (for AC input), pollution degree 2 Operating temperature range 0 to 40 °C Storage temperature –20 to 70 °C Relative humidity Up to 95% Altitude Up to 2000 meters Electromagnetic compatibility Compliant with EMC Directive (2004/108/EC) IEC 61326-1:2012/EN 61326-1:2013 Group 1 Class A Canada: ICES-001:2004 Australia/New Zealand: AS/NZS South Korea KC mark Safety UL 61010-1 3rd edition, CAN/CSA-C22.2 No. 61010-1-12, IEC 61010-1:2010 3rd edition AC input 100, 115, or 230 V input (±10%), 50/60 Hz,
250 VA for E36311A and E36312A; 600 VA for E36313A
Net weight Refer to the next table Dimensions Refer to the next table E36311A E36312A E36313A Weight 8.1 kg 8.3 kg 9.8 kg Overall dimension (H x W x D) 145 x 216 x 364 mm 145 x 216 x 367 mm 145 x 216 x 367 mm Net dimension (without feet, strap handle, and GPIB module) (H x W x D) 133 x 213 x 364 mm 133 x 213 x 364 mm 133 x 213 x 364 mm
Ordering Information
Keysight E36300 Series power supplies E36311A 80 W DC power supply, triple-output, 6 V, 5 A and ±25 V, 1 A, USB E36312A 80 W DC power supply, triple-output, 6 V, 5 A and 2 x 25 V, 1 A, LAN, USB E36313A 160 W DC power supply, triple -output, 6 V, 10 A and 2 x 25 V, 2 A, LAN, USB Standard shipped accessory AC power cord (based on destination country) Connectors E36311A None 36312A/13A EConnector kit (P/N: E36312-89001) One 10 A, 3.5 mm female 4-pin terminal block connector One 12 A, 5 mm female 4-pin terminal block connector One 15 A, 5 mm female 8-pin terminal block connector
Keysight enabl es inno vato rs to push the bound ari es of engineering by qui ckl y sol ving design, emulation, and test chall enges to create th e best produ ct experi ences. Start you r innovation journ ey at www.keysight.co m . This information is subject to chang e without notice. © Keysight Technologies, 2018 - 2023, Published in USA, Augu st 25, 2023, 5992 -2124EN Ordering options Option 0E3 230 VAC ±10% Option 0EM 115 VAC ±10% Option 0E9 100 VAC ±10% Option RBP Recessed binding posts, not upgradable Option GPB GPIB module Option UK6 Commercial calibration with test result data Option SEC NISPOM and file security BV0003B Power Supply Control & Automation Rackmount kit 1CM116A Rack Mount Flange Kit with one flange bracket, one half-module bracket 1CM104A Rack Mount Flange Kit with two flange brackets 1CM105A Rack Mount Flange Kit without handles and two flange brackets 1CN107A Handle Kit with two front handles 1CP108A Rack Mount Flange and Handle Kit with two brackets and front handles Upgrade (post-purchase) E363GPBU GPIB user installable interface module for E36312A, E36313A Additional Information www.keysight.com/find/e36300 www.keysight.com/find/e36311A www.keysight.com/find/e36312A www.keysight.com/find/e36313A www.keysight.com/find/e36300firmware