Technical content
– 1-Siot, C-size, message based – 200 MHz frequency range, optional 2.5 GHz channel – 9-digit resolution in 1 second gate time – 2 ns time interval resolution (200 ps with averaging) – Shared memory option configuration – Phase measurement and measurement timeout Keysight E1420B High-Performance VXI Universal Counter Data Sheet
Single Measurement Auto-Trigger Speeds Measurements Repetitive auto-trigger measurements are faster than ever with the E1420B’s single measurement auto-trigger. This feature ana - lyzes the input signal only once, setting the trigger levels, and speeding through the rest of the measurements. Adjustable Sensitivity Measuring low-level signals isn’t a problem: the Keysight E1420B features 35 mV rms sensitivity to 200 MHz. When noise is a problem, this sensitivity can be decreased to 100 mV rms by us - ing hysteresis control. Optional 2.5 GHz Channel (Input 3) Increase your frequency range to 2.5 GHz for communications and navigation applications. Save on Software Costs with SCPI The E1420B features the industry standard SCPI interface lan - guage. SCPI will let you develop code that can easily be lever - aged, increase the life of test software , and decrease the time spent learning new instrument languages. SCPI also simplifies the use of the counter; for example, you can set a trigger level using a percentage of signal amplitude.
Description
The Keysight Technologies, Inc. E1420B High-Performance Uni - versal Counter is a C-size, 1-slot, message-based VXI module. It provides the full set of traditional universal counter measure - ments (frequency, period, time interval, totalize, and ratio), plus the automatic measurements of rise/fall time, pulse width, phase, and AC/DC voltages. Additionally, this module provides xlO attenuation, allowing measurements of higher-powered signals. The E1420B is ideal for today’s ATE applications requiring high speed in all phases of a measurement - setup, measure, and output. It can make up to 60 measurements per second of the same function. It can also sequence through a series of different functions at up to 40 measurements per second. For even faster measurements, the optional shared memory capability yields up to 160 measurements per second. This shared RAM option allows the El420B to send measurement data to a VXI device with shared RAM. Data may be accessed by the controller, thus eliminating data formatting time and providing higher measure - ment throughput. The El420B features the industry standard SCPI interface lan - guage. SCPI will let you develop code that can easily be lever - aged, increase the life of test software, and decrease the time spent learning new instrument languages. Refer to the Keysight Technologies website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable. Outstanding Resolution and Range The E1420B offers a 200 MHz frequency range (2.5 GHz with option 030) and 2 ns time interval resolution (200 ps with aver - aging). Rise and fall times can be measured automatically down to 15 ns. Improve the System Clock Without Sacrificing Mainframe Space An optional highly stable TCXO time-base is available for the E1420B. By externally driving the VXI system clock (CLK10) with this TCXO, you can substantially reduce system clock errors without losing valuable mainframe slots. This option improves measurement repeatability and accuracy. Measurement Timing Control For synchronizing your measurement to an external event, such as an RF burst, VXI bus and external triggering are available. Programmable measurement time-outs help you optimize system performance even if the input signal is absent. 02 | Keysight | E1420B High-Performance VXI Universal Counter - Data Sheet
Period: Yes Time interval: Yes Totalize: Yes Gated totalize: Yes Ratio: Yes Pulse width: Yes Rise/fall time: Yes Phase: Yes VDC: Yes VAC: Yes Up/down counter: No Measurements Frequency: 200 MHz (standard) 2.5 GHz (with option) Frequency 1, 2, 3: Range: 0.001 Hz to 200 MHz. input 1; 0.001 Hz to 100 MHz. input 2: 90 MHz to 2.5 GHz. input 3 (Optional) Resolution: 9 digits/s of measurement time + trigger error + system jitter (Frequency resolu- tion is directly proportional to gate time. For example. resolution is 9 digits for a 1-second gate time and 8 digits for a 0.1-second gate time.) Period 1, 2, 3: Range: 5 ns to 1,000 s. input 1; 10 ns to 1000 s. input 2; 400 ps to 10 ns. input 3 (Optional) Resolution: Same as Frequency Time interval (TI) 1 to 2: Range: 1 ns to 1.000 s (single-shot): 1 ns to 10 s (averaging) (100-gate average) Resolution: 2 ns +trigger error, single-shot: 200 ps +trigger error averaging Rise/fall time 1:* Range: 15 ns to 400 μsec (automatic); to 800 sec (manual) Resolution: Same as TI Pulse width 1, 2:* Range: 5 ns to 1 ms Resolution: Same as TI Phase 1 relative 2:* Range: 0.1° to 360° Resolution: TI resolution x frequency x 360° Range ( 1/2,2/1): 0.001 Hz to 100 MHz Range (3/ 1): 90 MHz to 2.5 GHz (Optional) Measurements (continued) Totalize 1, 1 by 2, 2 by 1: Range: 0 to (1 x 1.0E12 •1) events Min / max. AC voltage 1, 2:* Range: 200 mVp-p to 5 Vp-p (x Atten.) Resolution: 30 mV (x Atten.) Min / max. DC voltage 1: Range: 30 mV to ±10 V (x A tten.) Resolution: 30 mV (x Atten.) *Frequency range 1 kHz to 20 MHz. Input Characteristics for Channels 1.2 Sinewave sensitivity: 35 mV rms Pulse sensitivity: 100 mVp-p (with minimum pulse width of 5 ns) Dynamic range: 200 mVp-p to 5 Vp-p (x Atten.) Attenuator: x1 (default) or x10 Signal operating range: ± 10 V (x Atten.) ( 1 MQ); ± 5 V (50 Ohm) Trigger level range: ± 10.2 V with step size of 2.5 mV (Specified by V or % of signal) Trigger level accuracy: ± 30 mV (x Atten.) ± 1% of trigger level Coupling: AC/DC Impedance: 50 Ω/1 MQ (default programmable) Slopes: Positive or Negative Input: Separate or Common (1 routed to 2) General Characteristics Gate time: 1 ms to 99.99s in 1 ms steps External arm: via front-panel BNC or VXI TIL TRIG lines Auto trigger: Range: 1 kHz to 20 MHz (Single or Repetitive Range) Minimum amplitude: 200 mVp-p (x Attn.) TI delay (inserts delay after start event before allowing stop event to occur): Range: 1 ms to 99 s in 1 ms step Measurement timeout: 0.1 s to 1.500 s Gate output: VXI TTLTRIP Lines Measurement throughput rate (measured using Radi - sys EPC-2): Free-run: Up to 60 Measurements /s Switching: Up to 40 Measurements /s Shared memory (option 040): Up to 160 Measurements/s Memory states 10 setups can be stored and recalled (Volatile) 03 | Keysight | E1420B High-Performance VXI Universal Counter - Data Sheet
Standard: VX I CLK10 Option 010 TCXO time base: Frequency: 10 MHz Aging: <0 .1 ppm/ month Temperature: ± 1 ppm.0 to 40° C UHF Channel (Input 3) (Option 030) Frequency range: 90 MHz to 2.5 GHz Sensitivity (sinewave):
90 MHz - 1 GHz: -25 dBm
1 GHz - 1.8 GHz: -20 dBm 1.8 GHz - 2.5 GHz: -12 dBm Shared Memory (Option 040) Shared memory throughput rate: Up to 160 Measurements/s General Specifications VXI Characteristics VXI device type: Message based Size: C Slots: 1 Connectors: P1/2 Shared memory: Yes VXI buses: TTL Trigger Bus Instrument Drivers - See the Keysight Technologies Website (www.keysight.com/find/ inst_drivers ) for driver availability and downloading Command module firmware: n/a Command module firmware rev: n/a 1-SCPI Win 3.1: n/a 1-SCPI Series 700: n/a C-SCPI LynxOS: n/a C-SCPI Series 700 n/a Panel Drivers: Yes VXIplug&play Win Frame- work : Yes VXIplug&play Win 95/ NT Framework: Yes VXIplug&play HP-UX Framework: No Module Current IPM IDM +5 V: 2 0.15 +12 V: 0.25 0.01 -12 V: 0.15 0.02 +24 V: 0 0 -24 V: 0 0 -5.2 V 0.8 0.03 -2 V: 0 0 Cooling/ Slot Watts/ slot: 15.50 DP mm H20: 0.15 Air Flow liter/s: 1.00
Ordering Information
Description Product No. High -Performance VXI Universal Counter E1420B TCXO Time Base E1420B 010 UHF Input Channel E1420B 030 High Throughput/ Shared RAM E1420B 040 Reduced TI Delay Spec E1420B 100 Service Manual E1420B OB3 04 | Keysight | E1420B High-Performance VXI Universal Counter - Data Sheet
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight T&M Software and Connectivity www.keysight.com/find/connectivity Keysight’s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. For more information visit: www.keysight.com/find/vxi For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) 05 | Keysight | E1420B High-Performance VXI Universal Counter - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2005 - 2014 Published in USA, July 31, 2014 5965-5548E www.keysight.com