DTW LINKCOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

  • AC Input 100~277VAC
  • Built-in Active PFC Function
  • Protection: SCP / OVP / OTP
  • Optional Auxiliary Output 3.3V or 5V (BLE models not applicable)
  • 0-10V or BLE Dimming Control / Dim-to-off
  • High Operating Ambient Temp.: 0 ℃~+50 ℃
  • Surge protection: L-N 1KV
  • Safety: UL 8750
  • EMI: FCC Part 15 Class B / CE
  • Warranty: 3 years (refer to warranty policy)
  • RoHS Compliant 0-10V Dimming Control Models 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC BLE Dimming Control Models PRODUCT SPECIFICATION MODEL DC OUTPUT POWER (W) DC OUTPUT VOLTAGE (V) OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE EFFICIENCY (Typ.) Power Factor (Typ.) 0~10V Dimmable / BLE Dimmable 22.5 DTW010U351FFA0 10.5 0.35
  • Built-in Dim to Warm / Brt. Adj / BLE (BLE models only) ±10% 1 ±10% ±10% ±10% ±13% Power Supply DTW Series DTW025U751FFA0 PRODUCT SPECIFICATION EFFICIENCY (Typ.) ±13% FEATURES: Power Factor (Typ.) 12.6 0.75
  • Comply with Indoor DC OUTPUT VOLTAGE (V) 21-30 MODEL DC OUTPUT POWER (W) OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE DTW020U501FFA0 21 ±10% 21-36 0.35 DTW025U701FFA0 25.2 0.7 ±10% DTW013U351FFA0 DTW030U102FFA0 30 21-30 ±13% 0.2 DTW030U701FFA0 29.4 0.7 21-30 21-36 21-36 DTW015U351FFA0 DTW015U501FFA0 18 0.5 0.3 21-42 0.5 21-42 14.7 21-42 0.35 28 28-56 0.5 ±13% ±13% ±10% 11.2 28-56 16.8 28-56 DTW030U501FFA0 DTW010U201FFA0 DTW020U301FFA0 100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC Model Number Code Units Vac Hz A A mA DTW020U301BFN0 16.8 28-56 0.3 ±13% DTW030U501BFN0 28 28-56 0.5 ±10% DTW030U701BFN0 29.4 21-42 0.7 ±10% DTW010U201BFN0 11.2 28-56 0.2 ±13% DTW020U501BFN0 21 21-42 0.5 ±10% DTW015U351BFN0 14.7 (W) (V) (A) DTW015U501BFN0 18 TOLERANCE DTW025U701BFN0 25.2 21-36 0.7 ±10% 21-42 0.35 ±13% DTW013U351BFN0 12.6 21-36 0.35 ±13% 21-36 0.5 ±10% 21-30 0.75 ±10% DTW030U102BFN0 30 21-30 1 ±10% DTW025U751BFN0 DTW010U351BFN0 10.5 21-30 0.35 22.5 ±13% Max. Conditions/Description Input Voltage Range 90 305 Input Frequency Range 47 63 Input Current 0.39 100VAC in Inrush Current 10 230VAC in,25 ℃ Cold start Leakage Current 0.75 277VAC in Power Factor (PF) 0.9 100-277VAC,100% load Total Harmonics Distortion (THD) 20 Typ. Input Specifications Min. D T W Series □ □ □ Pout 010 = 10W 020 = 20W U Safety U = UL □ □ □ Iout 701 = 700mA 501 = 500mA F / B Dimming control function F = 0~10V B = Bluetooth F A /N Auxiliary Voltage A = Aux 5V N =non Aux Linkcom Manufacturing Co., Ltd.

V s V A Units Units %RH %RH g 0.03 Auxiliary Output Voltage Auxiliary Output Source Current 0 0~10V Dimmable / BLE Dimmable 5 ± 10% Tolerance (Available for customization) Non-condensing 90 Min. Max. Conditions/Description Line Regulation Typ. Load Regulation Output Current Regulation ±13 Ripple and Noise (pk-pk) 2 20MHz Bandwidth. See note (3) Ripple Current <30% of rated output current *Measured at electronic load LED mode and nominal input voltage with DC10V dimming. Turn-on Delay Time 1 Measured at 100-277VAC and at full load Protection Functions Min. Max. Conditions/Description Short Circuit Protection will restart automatically after the fault condition is removed Over Voltage Protection will restart automatically after the fault condition is removed Over Temp Protection (Tc) will restart automatically after the fault condition is removed Environmental Conditions Min. Max. Conditions/Description Operating Temperature (Ta) 0 50 Non-condensing Operating Case Temperature (Tc) 75 Case temperature measured at the case hot spot Measured at 100Vac,Ta 50 ℃ Operating Humidity 10

80 Non-condensing

Storage Humidity 10 95 Non-condensing Life Time Measured at 277Vac, 56,000 hours at Ta 50°C for DTW030U112FFA0. Dimensions(L*W*H) 95 * 69 * 29 mm 3.74 * 2.72 * 1.14 inch Weight RF Electromagnetic Field Susceptibility Electrical Fast Transient

8 KV air discharge, 4 KV contact discharge

Typ. Comply with IEC 61000-4-3 Comply with EN 61000-3-2 EMC Compliance and Safety EMC Compliance Voltage Fluctuations & Flicker Electrostatic Discharge (ESD) Comply with EN 61000-3-3 Storage Temperature Comply with IEC 61000-4-2 Comply with EN 55015 (CISPR15) 110 Conducted and Radiated Emmission Harmonic Current Emissions Typ. Output Specifications -20 (1) All parameters not specially mentioned are measured 230VAC input. (2) All specifications Typical @25 ℃, unless otherwise noted, at normal line and load. *Please contact sales@linkcom.com.tw , sales@linkcomusa.com for more information Safety Conducted RF Disturbances Surge Immunity Comply with IEC 61000-4-5 (4) Specified for free-air convection cooling. Power Frequency Magnetic Field Voltage Dips Comply with IEC 61000-4-6 Comply with IEC 61000-4-8 Comply with IEC 61000-4-11 EMS Standards UL Comply with UL 8750 *REFERENCE: www.linkcom.com.tw Notes (3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. L-N 1KV Linkcom Manufacturing Co., Ltd.

DIMENSIONS (0-10V Dimming Control Models) *The above mechanical diagram is for reference only. The actual product should be in accordance with the specification 0~10V Dimmable / BLE Dimmable DERATING CURVE for approval. *REFERENCE: www.linkcom.com.tw Linkcom Manufacturing Co., Ltd.

Output Current vs. Load (DTW030U102FFA0) Efficiency vs. Load (DTW030U102FFA0) 0~10V Dimmable / BLE Dimmable 0.400 0.500 0.600 0.700 0.800 0.900 1.000 1.100 70% 75% 80% 85% 90% 95% 100% 105% Output Current (A) Load (%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 80% 90% 100% Efficiency (%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 THD vs. Load (DTW030U102FFA0) 60% 70% 70% 75% 80% 85% 90% 95% 100% 105% Load (%) Vin=200 Vin=230 Vin=277 10% 20% 30% 70% 75% 80% 85% 90% 95% 100% 105% THD (%) Load (%) THD vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 Linkcom Manufacturing Co., Ltd.

PF vs. Load (DTW030U102FFA0) Dimming Performance (DTW030U102FFA0) Brightness DC 10V, CCT DC 0V~10V (CCT adjustment) 0~10V Dimmable / BLE Dimmable 0.60 0.70 0.80 0.90 1.00 70% 75% 80% 85% 90% 95% 100% 105% Power Factor Load (%) PF vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=277 50% 60% 70% 80% 90% 100% Output Current (%) CCT Changing Performance CCT DC 0V/10V Dim DC 0V~10V (brightness adjustment) 10% 20% 30% 40% 0 1 2 3 4 5 6 7 8 9 10 Output Current (%) Vdc (V) 120V Cold 120V Warm 277V Cold 277V Warm 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0 1 2 3 4 5 6 7 8 9 10 Output Current (%) Vdc (V) Dimming Performance 120V Cold 120V Warm 277V Cold 277V Warm Linkcom Manufacturing Co., Ltd.