6000X KEYSIGHT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 45

Technical content

InfiniiVision 6000 X-Series Oscilloscopes Data Sheet

02 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Need more memory, bandwidth, analysis capability, or bits? Consider the Infiniium S-Series – 500 MHz, 1 GHz, 2 GHz, 2.5 GHz, 4 GHz, 6 GHz, 8 GHz – 20 GSa/s – 100 Mpts standard, up to 800 Mpts optional (half channel) – 4 channels + 16 digital channels (MSO or upgrade) – 10 bits of vertical resolution – Industry’s largest 15-inch touch display – Widest range of applications including serial compliance, jitter analysis and more See www.keysight.com/find/S-Series for details. Table of Contents

03 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet In the past, if you wanted an oscilloscope with exceptional performance, you could expect to pay a premium. Not anymore. The InfiniiVision 6000 X-Series oscilloscopes combine price and performance to set a new standard in the portable oscilloscope world. Imagine a 6 GHz bandwidth oscilloscope that sees and triggers on everything, helps you visualize complex waveforms and grows with your projects. The InfiniiVision 6000 X-Series oscilloscopes are designed for the most demanding engineers who want bandwidth, visualization power and the flexibility that comes with integrated capabilities — but with portability, a familiar embedded OS user interface, and an affordable price. New bandwidth standard: Capture higher- frequency waveforms An oscilloscope’s bandwidth determines the maximum frequency content it can acquire and visualize. In today’s budget-challenged environment, engineers frequently are forced to make compromises between more bandwidth and limited budget. The

6000 X-Series delivers the answer with an affordable 6-GHz

bandwidth and an incredibly low noise floor of 210 µVrms at 1 mV/div to help you make the most accurate measurements. New visualization standard: Isolate waveforms of interest The new InfiniiVision 6000 X-Series’ 450,000 waveforms-per- second update rate coupled with the exclusive hardware-based zone touch trigger provide unprecedented visualization power to help you isolate your waveforms of interest. Add a whole new depth of “visualization” to your designs with features like the industry’s first 12-inch multi-touch capacitive touch screen with gesture support, the first embedded-OS-oscilloscope optional jitter/real-time eye analysis, and standard histogram and color grade. New integration standard: Make your job easier The 6000 X-Series has 7-in-1 integration, combining digital channels, serial protocol analysis, a built-in dual-channel waveform generator, frequency response analysis, built-in digital multimeter, and built-in 10-digit counter with totalizer. It also integrates multi-language voice control for the first time in an oscilloscope. It weighs only 6.8 kg, measures only 15.4 cm deep, and consumes only 200 W, making the 6000 X-Series the world’s most environmentally-friendly multi-GHz portable oscilloscope. The InfiniiVision 6000 X-Series sets the new standard. Key features of the 6000 X-Series oscilloscopes New bandwidth standard: – Portable, 6-GHz, 20-GSa/s – 210-µVrms noise floor at 1 mV/div (6 GHz) – 115-µVrms noise floor at 1 mV/div (1 GHz) New visualization standard: – > 450,000 wfms/sec update rate – Hardware zone touch trigger – 12.1-inch capacitive multi-touch screen – Histogram, color grade, jitter analysis (option), real-time eye diagram analysis (option), and more New integration standard: – 7 instruments in 1 (now with 10-digit counter) – Standard multi-language voice control – Bandwidth and options are upgradable New Standard for Price Performance: Bandwidth, Visualization, and Integration

04 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Overview of the Keysight InfiniiVision X-Series oscilloscopes InfiniiVision 6000 X-Series 4000 X-Series 3000T X-Series 2000 X-Series 1000 X-Series Analog channels 2 or 4 2 or 4 2 or 4 2 or 4 2 Digital channels (MSO) 16 16 16 8 External trigger can be used as a 3rd digital channel Bandwidth (upgradable) 1, 2.5, 4, 6 GHz 200, 350, 500 MHz, 1,

1.5 GHz

100, 200, 350, 500 MHz, 1 GHz 70, 100, 200 MHz 50, 70, 100 MHz Max sampling rate 20 GSa/s 5 GSa/s 5 GSa/s 2 GSa/s 2 GSa/s Max memory depth 4 Mpts 4 Mpts 4 Mpts 100 kpts (standard)

1 Mpts (option)

450,000 waveforms/sec > 1,000,000 waveforms/sec > 1,000,000 waveforms/sec > 50,000 waveforms/sec > 50,000 waveforms/sec Display 12.1 inches, capacitive, multi-touch, gesture enabled 12.1 inches, capacitive 8.5 inches, capacitive 8.5 inches 7 inches Zone trigger Standard Standard Standard No No Voice control Standard No No No No 20-MHz function/ arbitrary waveform generator Dual-channel AWG (option) Dual-channel AWG (option) Single-channel AWG (option) Single-channel function (option) Single-channel function (standard on G models) Integrated DVM Standard Standard Standard Standard Free with registration Integrated hardware counter (standard) 10-digit frequency, period, or totalizer counter 5-digit frequency or period counter (8 digits with external 10 MHz clock reference) 8-digit frequency, period, or totalizer counter 5-digit frequency counter 8-digit frequency counter Search and navigate Standard with lister Standard with lister Standard with lister Standard No Segment memory Standard Standard Standard Option Standard on DSO models Mask/limit test Option Option Option Option Standard on DSO models Serial protocol analysis options I 2C/SPI, UART, CAN/CAN-FD, LIN, FlexRay, SENT, I2S, MIL-S T D15 5 3 / ARINC429, USB 2.0, CXPI, Manchester/NRZ, USB PD I 2C/SPI, UART, CAN/CAN-FD, LIN, FlexRay, SENT, I2S, MIL-S T D15 5 3 / ARINC429, USB 2.0, CXPI, Manchester/NRZ, USB PD I 2C/SPI, UART, CAN/ CAN-FD, LIN, FlexRay, SENT, I2S, MIL- STD1553/ARINC429, CXPI, Manchester/ NRZ, USB PD I 2C/SPI, UART, CAN/ LIN (will not operate simultaneously with digital channels) I2C/SPI, UART, CAN/ LIN Advanced analysis options Power analysis, USB 2.0 signal quality test, HDTV analysis, FRA Power analysis, USB 2.0 signal quality test, HDTV analysis, FRA, NFC Power analysis, HDTV analysis, FRA, NFC No FRA Color grade Standard No No No No Histogram Standard No No No No Spectrum analysis Standard enhanced FFT Standard enhanced FFT Standard enhanced FFT Standard Standard Multi-domain analysis Gated FFT Gated FFT Gated FFT No No Jitter analysis Option No No No No Real-time eye diagram Option No No No No Advanced math Standard, display four functions simultaneously Standard, display one function Standard, display one function No No Connectivity Standard USB 2.0, LAN, video (GPIB option), USB mouse and keyboard support Standard USB 2.0, LAN, video (GPIB option), USB mouse and keyboard support Standard USB 2.0 (LAN/video/GPIB option), USB mouse and keyboard support Standard USB 2.0 (LAN/video/GPIB option), USB keyboard support Standard USB 2.0, USB keyboard support New Standard for Price Performance: Bandwidth, Visualization, and Integration

6 GHz Noise floor: 210 µVrms at 1 mV/div

set the best bandwidth for your application. software license installation.

6000 X-Series, the multi-GHz bandwidth no longer necessitates

portability and performance at the same time. Figure 6. Measuring the noise floor of a 6-GHz scope at 1 mV/div. Figure 5. The new 6-GHz front-end design. Figure 7. You can set the hardware bandwidth limit control interface per Figure 8. One- gigahertz-per-inch form factor: 6 GHz, 6 inches deep.

6000 X-Series can be set up to easily trigger on one or two zone

words, if you can see it, you can trigger on it. Figure 11. Draw a zone (box) around the anomaly. Figure 12. Hardware zone triggers immediately. Figure 13. Setting up the zone trigger in addition to a CAN bus error Figure 14. Now you have isolated steering errors from all other CAN bus

6000 X-Series’ color grade operates like a separate function with

Figure 15. Color grade and histogram on a jittery clock edge. Figure 16a. Color grade and histogram on an FFT function.

Figure 22. Segmented memory graphical representation. segment relative to the first trigger event. 640 Gpts of memory is required to do similar analysis. with the color grade and histogram features as well. Figure 23. Segmented memory and color grade. Figure 24. Segmented Figure 25. Segmented memory + serial bus decode + zone trigger.

200 CAN steering and airbag errors over a 30-second time span

duration equates to 192 Mpts of traditional memory.

Figure 31. DVM display. these quick characterization measurements at your fingertips. Vin) and phase logarithmically.

traditional analog oscilloscope. See www.keysight.com/find/DSOX6VID for more information. select the optimal bandwidth for your measurement.

1 MΩ 20 MHz, 200 MHz

3 GHz 2

1 Hz through bandwidth of

  1. With 2.5 GHz, 4 GHz, or 6 GHz licensed 6000 X-Series only.
  2. With 4 GHz or 6 GHz licensed 6000 X-Series only.

8-bit vertical resolution of the 6000 X-Series oscilloscopes. and effectively increases vertical resolution up to 12 bits. Figure 45. Triggering on a 1080p/60 signal.

back) and device ports (one on back) make PC connectivity easy. adapter is also available (N4865A). control your 6000 X-Series with a mobile device from anywhere. www.keysight.com/find/benchvue . Figure 52. Connectivity section on the back panel.

28 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Designed for Touch. 12.1-inch capacitive multi-touch screen with gesture support sets a new visualization standard. Not a touch screen fan? You can turn off the touch screen. Zone touch trigger. If you can see it, you can trigger on it by drawing a zone box. 7-in-1 instrument sets a new integration standard: oscilloscope channels, digital channels, serial protocol analysis, dual- channel WaveGen, frequency response analysis, digital voltmeter, and 10-digit counter-totalizer. Fully upgradable , including bandwidth. Standard color grade and histogram on a waveform, measurement, or math function adds statistical view. Jitter and real-time eye diagram analysis is available for the first time ever in an embedded-OS-platform oscilloscope. Dual-channel WaveGen function/arbitrary generator allows you to generate differential, clock and data, two channel modulation, and IQ signals. Modulation capability included. Both USB keyboard and mouse are supported in 6000 X-Series for additional ease of use. The portable oscilloscope class-leading

6 GHz upgradable bandwidth expands your

application coverage including PCI Express. New Standard for Price Performance: Bandwidth, Visualization, and Integration

29 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Wide coverage of application and serial protocol solutions including USB 2.0 signal quality analysis . Four AutoProbes (active and current probes) are supported simultaneously for demanding applications. 450,000 waveforms per second update rate minimizes the dead-time for maximum probability of capturing infrequent events and anomalies. Multi-language voice control enables hands-free operation while you are holding probes. Using docking panels with the capacitive touch screen adds a new dimension of usability. Move automatic measurements, cursors information, event lister, histogram, navigation, DVM, and the counter pane anywhere on the screen. Transparent panes are supported. Standard advanced math displays four functions simultaneously for the most sophisticated signal analysis. Display up to 10 measurements with statistics simultaneously without compromising other key information. Supports 56 automatic measurements and gating by cursors . Industry’s only integrated digital voltmeter and 10-digit counter with totalizer . Independent knobs per channel for fast operation. All front-panel knobs are push-able for access to common controls such as fine and coarse control. Standard segment memory with event lister is powered by MegaZoom IV smart memory technology to intelligently capture only the signals of interest.

30 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Configure your InfiniiVision 6000 X-Series Oscilloscope Step 1. Choose your number of channels InfiniiVision 6000 X-Series oscilloscopes Input channels DSOX6002A 2 DSOX6004A 4 MSOX6002A 2 + 16 MSOX6004A 4 + 16 Step 2. Choose your bandwidth Bandwidth options 1 GHz 2.5 GHz 4 GHz 6 GHz For 2 channel models Default DSOX6B10T252BW DSOX6B10T402BW DSOX6B10T602BW For 4 channel modes Default DSOX6B10T254BW DSOX6B10T404BW DSOX6B10T604BW * Examples If you want 1 GHz, 4 + 16 channel, the model configuration will be MSOX6004A only If you want 4 GHz, 4 + 16 channel, the model configuration will be MSOX6004A and DSOX6B10T404BW Step 3. Tailor your oscilloscope with measurement applications to save time and money Bandwidth, feature, and application upgrades Model number Application bundle Software application bundle DSOX6APPBNDL (includes DSOX6EMBD, DSOX6COMP, DSOX6USBFL, DSOX6USBH, DSOX6AUTO, DSOX6FLEX, DSOX6AUDIO, DSOX6AERO, DSOX6JITTER, DSOX6WAVEGEN2, DSOX6PWR, DSOX6MASK, DSOX6USBSQ, DSOX6VID, DSOX6SENSOR, DSOX6CXPI, DSOX6NRZ, DSOX6FRA) Serial protocols MIL-STD 1553 and ARINC 429 serial triggering and analysis DSOX6AERO Audio serial triggering and analysis (I 2S) DSOX6AUDIO Automotive serial triggering and analysis (CAN, CAN-dbc, CAN-FD, LIN) DSOX6AUTO Computer serial triggering and analysis (RS232/UART) DSOX6COMP Embedded serial triggering and analysis (I 2C, SPI) (SPI requires 4, 2+16, or 4+16 channel 6000 X-Series) DSOX6EMBD FlexRay serial triggering and analysis DSOX6FLEX SENT (Single Edge Nibble Transmission) triggering and analysis DSOX6SENSOR CXPI triggering and decode DSOX6CXPI USB 2.0 Full/Low Speed serial decode and triggering DSOX6USBFL USB 2.0 Hi-Speed serial decode and triggering DSOX6USBH USB PD serial decode and triggering DSOX6UPD User-definable Manchester/NRZ triggering and decode DSOX6NRZ Measurement applications Jitter and real time eye diagram analysis DSOX6JITTER Mask limit testing DSOX6MASK Frequency Response Analysis (FRA) DSOX6FRA Power analysis application DSOX6PWR USB 2.0 signal quality test DSOX6USBSQ Enhanced video/TV application package DSOX6VID Dual channel WaveGen 20 MHz AWG DSOX6WAVEGEN2 Productivity tools Infiniium offline oscilloscope analysis software N8900A User-defined Application (UDA) PC software N5467B/C BenchVue oscilloscopes application BV0004B

31 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Configure your InfiniiVision 6000 X-Series Oscilloscope (Continued) Step 4. Choose your probes. For a complete list of compatible probes, see Keysight document 5968-8153EN Probes Standard/Optional N2894A passive probe 700 MHz, 10:1, 9.5 pF, 10 MΩ Included standard; 1 per channel N2756A 16 digital channel MSO cable Included standard on MSOX models and DSOX6MSO N2870A passive probe 35 MHz, 1:1, 1 MΩ Optional 10076B high-voltage passive probe (4 kV) Optional N2796A active single-ended probe 2 GHz, 1 pF, 1 MΩ with AutoProbe Optional N2797A active single-ended probe 1.5 GHz, extreme temperature Optional N2750A InfiniiMode differential probe 1.5 GHz, 700 fF, 200 kΩ with AutoProbe Optional N2751A InfiniiMode differential probe 3.5 GHz, 700 fF, 200 kΩ with AutoProbe Optional N2752A InfiniiMode differential probe 6.0 GHz, 700 fF, 200 kΩ with AutoProbe Optional N2790A differential active probe 100 MHz, ± 1.4 kV, 4 MΩ with AutoProbe Optional N2819A 800-MHz, 10:1 differential probe, 200 kΩ with AutoProbe Optional 1147B AC/DC current probe, 50 MHz, 15 A with AutoProbe Optional N2893A AC/DC current probe, 100 MHz, 15 A with AutoProbe Optional N2820A 2-channel high-sensitivity current probe, 50 µA to 5 A Optional 54855-67604 Precision BNC to SMA adapter Optional N7020A power rail probe 2 GHz, 1:1, 50 kΩ, ± 24 V offset range Optional N2804A high voltage differential probe, 300 MHz, ± 300 V (DC + peak AC), 100:1, 4-MΩ, 4 pF Optional N7040A 23 MHz, 3 kA, AC current probe Optional N7041A 30 MHz, 600 A, AC current probe Optional N7042A 30 MHz, 300 A, AC current probe Optional N7026A 150 MHz, 40 Apk, AC/DC high-sensitivity current probe with AutoProbe Optional Step 5. Choose your accessories and calibration plans Recommended accessories and calibration plans Model number GPIB connection module N4865A Rack mount kit N2111A Soft carrying case N2733B Hard copy manual N2112A Hard transit case - available from Case Cruzer (http://www.casecruzer.com/oscilloscope/3a1311-2710j.html ) 3A1311-2710J ANSI Z540-1-1994 calibration D/MSOX6000-A6J ISO17025 compliant calibration with accreditation D/MSOX6000-AMG After-purchase bandwidth and digital channel upgrades Recommended accessories Model number 1.0 to 2.5 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B10T252BW 1.0 to 4.0 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B10T402BW 1.0 to 6.0 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B10T602BW 2.5 to 4.0 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B25T402BW 2.5 to 6.0 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B25T602BW 4.0 to 6.0 GHz bandwidth upgrade, 2 ch, fixed perpetual license DSOX6B40T602BW 1.0 to 2.5 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B10T254BW 1.0 to 4.0 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B10T404BW 1.0 to 6.0 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B10T604BW 2.5 to 4.0 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B25T404BW 2.5 to 6.0 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B25T604BW 4.0 to 6.0 GHz bandwidth upgrade, 4 ch, fixed perpetual license DSOX6B40T604BW InfiniiVision 6000 X-Series oscilloscope MSO upgrade DSOX6MSO

32 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet DSOX/MSO 6000 X-Series digital storage/mixed signal oscilloscopes

6000 X-Series specification overview

Half channel bandwidth 1 (–3 dB) 1 GHz 2.5 GHz 4 GHz 6 GHz Full channel bandwidth 1 (–3 dB) 1 GHz 2.5 GHz 4 GHz 4 GHz Full channel equivalent time bandwidth 1 (–3 dB) N/A N/A N/A 6 GHz Calculated rise time (10 to 90%) ≤ 350 ps ≤ 140 ps ≤ 112.5 ps ≤ 75 ps Input channels DSOX6002A 2 DSOX6004A 4 MSOX6002A 2 + 16 MSOX6004A 4 + 16 Maximum sample rate 20 GSa/s half channels, 10 GSa/s full channels Maximum memory depth Standard 4 Mpts, Standard segment memory Display size and type 12.1-inch capacitive multi-touch/gesture-enabled display Waveform update rate > 450,000 waveforms per second Typical noise floor at 1 mV/div, 50 Ω 115 μVrms 150 μVrms 150 μVrms 210 μVrms Vertical system analog channels Hardware bandwidth limits

1 MΩ 20 MHz, 200 MHz (selectable per channel)

50 Ω 20 MHz, 200 MHz, 1.5 GHz, 3 GHz (selectable per channel) Input coupling AC, DC Input impedance Selectable: 1 MΩ ± 1% (14 pF), 50 Ω ± 3% Input sensitivity range 1 MΩ 1 mV/div to 5 V/div 2 (200 MHz bandwidth limit at ≤ 2 mV/div) 50 Ω 1 mV/div to 1 V/div 2 Vertical resolution 8 bits (measurement resolution is 12 bits with averaging) Maximum input voltage 1 MΩ 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk Frequency derating (assumes sine wave input): 400 Vpk until 40 kHz Then derates at 20 db/dec until 6 Vpk 50 Ω 50 Ω: ± 5Vpk max DC vertical gain accuracy 1 ± 3 div: 1.5% of full scale (typical) ± 4 div: 2.5% of full scale (warranted) 2 DC vertical offset accuracy ± 0.1 div ± 2 mV ± 1% of offset setting (valid for an offset of ≤ ± 12 divisions) Channel-to-channel isolation ≥ 100:1 (DC to 1 GHz), ≥ 30:1 (> 1 GHz) Offset range 1 MΩ ± 5 V (1 to < 10 mV/div), ± 20 V (10 to ≤ 200 mV/div), ± 100 V (> 200 mV/div) 50 Ω ± 12 div or ± 0.8 V, whichever is smallest (≤ 100 mV/div) ± 12 div or ± 4 V, whichever is smallest (> 100 mV/div) Dynamic range 1 MΩ ± 8 divisions from center screen (≤ 100 mV/div), 2nd harmonic distortion of - 40 dbc ± 4 divisions from center screen (> 101 mV/div), 2nd harmonic distortion of - 23 dbc (For a 10:1 probe on the 1 MΩ input, vertical scaling is multiplied by 10) 50 Ω ± 8 divisions from center screen Noise floor at 50 Ω 1 GHz 2.5 GHz 4 GHz 6 GHz 1 mV/div 115 µVrms 150 µVrms 150 µVrms 210 µVrms 10 mV/div 330 µVrms 355 µVrms 350 µVrms 395 µVrms 100 mV/div 3.15 mVrms 3.25 mVrms 3.20 mVrms 3.35 mVrms 1 V/div 31.5 mVrms 32.5 mVrms 32 mVrms 33.5 mVrms ESD tolerance ± 2 kV (on input BNCs) 1. D enotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 °C from firmware calibration temperature. 2. 1 mV/div is a magnification of 2 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting. Performance Characteristics

33 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Performance Characteristics (Continued) DSOX/MSO 6000 X-Series digital storage/mixed signal oscilloscopes (Continued) Vertical system digital channels Digital input channels 16 digital (D0 to D15. Pod 1: D7 ~ D0, Pod 2: D15 ~ D8) Thresholds Threshold per pod Threshold selections TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod) User-defined threshold range ± 8.0 V in 10-mV steps Maximum input voltage ± 40 V peak Threshold accuracy 1 ± (100 mV + 3% of threshold setting) Maximum input dynamic range ± 10 V about threshold Minimum voltage swing 500 mVpp Input impedance 100 kΩ ± 2% at probe tip Input capacitance ~8 pF Vertical resolution 1 bit Horizontal system analog channels 1 GHz 2.5 GHz 4 GHz 6 GHz Time base range 500 ps/div to 50 s/div 100 ps/div to 50 s/div 100 ps/div to 50 s/div 100 ps/div to 50 s/div Time base accuracy 1 ± 1.6 ppm + aging factor (1 year: ± 0.5 ppm, 2 years: ± 0.7 ppm, 5 years: ± 1.5 ppm, 10 years: ± 2.0 ppm) Time base resolution 2.5 ps Time base delay time range Pre-trigger Greater of 1 screen width or 50 µs Post-trigger 1 s to 500 s Channel-to-channel deskew range ± 100 ns Δ time accuracy (using cursors) Same channel: ± (time base accuracy x reading) ± (0.0016 x screen width) ± 10 ps Channel-to-channel: ± (time base accuracy x reading) ± (0.0016 x screen width) ± 15 ps Modes Main, zoom, roll, XY XY On channels 1 and 2 only. Z blanking on ext trigger input, 1.4 V threshold Bandwidth: maximum bandwidth. Phase error at 1 MHz: < 0.5 degree Horizontal system digital channels Minimum detectable pulse width 2 ns Channel-to-channel skew 2 ns (typical); 3 ns (maximum) 1. D enotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 °C from firmware calibration temperature.

34 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Acquisition system 1 GHz 2.5 GHz 4 GHz 6 GHz Maximum analog channels sample rate 20 GSa/s half channel interleaved, 10 GSa/s all channel Analog channels equivalent sample rate Not available 400 GSa/s Maximum analog channels record length ≤ 2 GSa/s 4 Mpts half channel interleaved, 2 Mpts all channel > 2 GSa/s 1 Mpts half channel interleaved, 500 kpts all channel Maximum digital channels sample rate 2 GSa/s half pods interleaved, 1 GSa/s all pods Maximum digital channels record length 4 Mpts half pods interleaved, 2 Mpts all pods Acquisition mode Normal Default mode Peak detect Analog channels: Capture glitches as narrow as 500 ps (half channel), 1 ns (all channel) Digital channels: Capture glitches as narrow as 500 ps (half pods), 1 ns (all pods) Averaging Selectable from 2, 4, 8, 16, 64, ... to 65,536 High resolution Real-time boxcar averaging reduces random noise and effectively increases vertical resolution 12 bits: ≥ 20 μs/div at 2 GSa/s or ≥ 50 μs/div at 1 GSa/s Segmented Segmented memory optimizes available memory for data streams that have long dead times between activity. Maximum segments = 1000. Re-arm time = As fast as 1 μs (minimum time between trigger events) Data acquisition mode Real time Default mode (> 135,000 waveforms/sec) Max update rate Enhanced real-time mode for the fastest waveform update rate of > 450,000 waveforms/sec. Up to 2 GSa/s. Returns to a normal real-time mode at > 2 GSa/s Equivalent Available with 6-GHz bandwidth license. The time base must be at 20 ns/div or faster. 2.5-ps fine interpolator resolution yields a maximum effective sample rate of 400 GSa/s Time mode Normal Default mode Roll Displays the waveform moving across the screen from right to left. Available at time bases 50 ms/div or slower XY Shows the volts-versus-volts display. Time base can be set from 200 ns/div to 50 ms/div Trigger system Trigger sources Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1, 2, or Mod (FM/FSK)) Trigger modes Normal Requires trigger event for oscilloscope to trigger Auto Triggers automatically but not synchronized to the input in absence of trigger event Single Front panel button that triggers only once on a trigger event. Press Single button again for oscilloscope to find another trigger event, or press Run front panel button to trigger continuously in either Auto or Normal mode Force Front panel button forces a synchronous trigger Trigger coupling DC DC-coupled trigger AC AC-coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external) HF reject High-frequency reject, cutoff frequency ~ 50 kHz LF reject Low-frequency reject, cutoff frequency ~ 50 kHz Noise reject Adds hysteresis to the trigger circuitry; selectable OFF or ON, decreases sensitivity 2x Trigger holdoff range 40 ns to 10.00 s Performance Characteristics (Continued)

35 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Trigger system Trigger jitter < 1.0-ps rms with the jitter-free trigger < 3.0-ps rms without the jitter-free trigger Trigger bandwidth Edge 500 MHz, 1 GHz, 2.5 GHz models: bandwidth of oscilloscope. 4-GHz and 6-GHz models: 3.5 GHz Other modes Bandwidth of oscilloscope or 1 GHz, whichever is smaller Trigger sensitivity (internal)

1 GHz bandwidth ≤ 10 mV/div DC to 1 GHz Greater of 1 div or 5 mVpp

10 mV/div DC to 1 GHz 0.6 div 2.5, 4, and 6 GHz bandwidth ≤ 10 mV/div DC to 2 GHz Greater of 1 div or 5 mVpp 2.0 to 3.5 GHz Greater of 1.5 div or 5 mVpp > 10 mV/div DC to 2 GHz 0.6 div 2.0 to 3.5 GHz 1.0 div Trigger sensitivity (external) ± 1.6 V 40 mVpp DC to 100 MHz, 70 mVpp 100 to 200 MHz ± 8 V 200 mVpp DC to 100 MHz, 350 mVpp 100 to 200 MHz Trigger level range Any channel ± 6 div from center screen External 8-V range = ± 8 V; 1.6-V range = ± 1.6 V 1. D enotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 °C from firmware calibration temperature. Trigger type selections InfiniiScan Zone (hardware zone qualifier) Trigger on user-defined zones drawn on the display. Applies to one analog channel at a time. Specify zones as either “must intersect” or “must not intersect.” Up to two zones. > 160,000 wfm/ sec update rate Supported modes: Normal, peak detect, high resolution, max update rate Also works simultaneously with the serial decodes and mask/limit test Edge Trigger on a rising and falling edge of any source, alternating or either edge of analog and digital channels Edge then edge (B trigger) Arm on a selected edge, wait a specified time, then trigger on a specified count of another selected edge. Minimum 4 ns Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value, or inside a time range – Minimum duration setting: 2 ns – Maximum duration setting: 10 s – Range minimum: 10 ns Pattern Trigger when a specified pattern of high, low, and don’t-care levels on any combination of analog, digital, or trigger channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as a valid trigger condition – Minimum duration setting: 2 ns – Maximum duration setting: 10 s Or Trigger on any selected edges from available sources (analog and digital channels only). Bandwidth is 500 MHz Performance Characteristics (Continued)

36 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Trigger type selections (Continued) Rise/fall time Trigger on rise time or fall time edge speed violations (< or >) based on user-selectable threshold. Select from (< or >) and time settings range between – Minimum: 1 ns – Maximum: 10 s Nth edge burst Trigger on the nth (1 to 65535) edge of a pulse burst. Specify idle time (10 ns to 10 s) for framing Runt Trigger on a position runt pulse that fails to exceed a high-level threshold. Trigger on a negative runt pulse that fails to drop below a low-level threshold. Trigger on either polarity runt pulse based on two threshold settings. Runt triggering can also be time-qualified (< or >) with a minimum time setting of 2 ns Setup and hold Trigger on setup/hold violations. Setup time can be set from –7 s to 10 s. Hold time can be set from 0 s to 10 ns. Minimum window (setup time + hold time) must be 3 ns or greater Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM, PAM-M) Enhanced video (HDTV) (Option) Trigger on lines and fields of enhanced and HDTV standards (480p/60, 567p/50, 720p/50, 720p/60, 1080p/24, 1080p/25, 1080p/30, 1080p/50, 1080p/60, 1080i/50, 1080i/60) ARINC429 (Option) Trigger and decode on ARINC429 data. Trigger on word start/stop, label, label + bits, label range, error conditions (parity, word, gap, word or gap, all), all bits (eye), all 0 bits, all 1 bits CAN (Option) Trigger on CAN (controller area network) version 2.0A,2.0B, and CAN-FD (Flexible Data-rate) signals. Trigger on the start of frame (SOF), the end of frame (EOF), data frame ID, data frame ID and data (non-FD), data frame ID and data (FD), remote frame ID, remote or data frame ID, error frame, acknowledge error, from error, stuff error, CRC error, spec error (ack or form or stuff or CRC), all errors, BRS Bit (FD), CRC delimiter bit (FD), ESI bit active (FD), ESI bit passive (FD), overload frame., message, message and signal (non-FD), message and signal (FD, first 8 bytes only) FlexRay (Option) Trigger on frame ID or specific error condition, along with cycle-base and repetition-cycle filtering. Can also trigger on specific events such as BSS, TSS, FES, and wake up I²C (Option) Trigger at a start/stop condition or user-defined frame with address and/or data values. Also trigger on missing acknowledge, address with no acq, restart, EEPROM read, and 10-bit write I²S (Option) Trigger on 2’s complement data of audio left channel or right channel (=, ≠, <, >, > <, < >, increasing value, or decreasing value) LIN (Option) Trigger on LIN (Local Interconnect Network) sync break, sync frame ID, frame ID and data , parity error, or checksum error MIL-S T D15 5 3 (Op t ion) Trigger on MIL-STD 1553 signals on data word start/stop, command/status start/stop, RTA, RTA + 11 bits, and error conditions (parity, sync, Manchester) SPI (Option) Trigger on SPI (Serial Peripheral Interface) data pattern during a specific framing period. Supports positive and negative Chip Select framing as well as clock Idle framing and user-specified number of bits per frame. Supports MOSI and MISO data UART/RS232/422/485 (Option) Trigger on Rx or Tx start bit, stop bit, data content, or parity error USB (Option) Trigger on start of packet (SOP), end of packet (EOP), suspend*, resume*, reset*, packets (token, data, handshake, or special), and errors (PID, CRC5, CRC16, glitch, bit stuff*, SE1***). Supports USB 2.0 low- speed, full- speed, and hi-speed implementations. (Hi-speed is supported on ≥ 1-GHz models only) SENT (Option) Trigger and decode on SENT bus. start of fast channel message, start of slow channel message, fast channel SC and data, slow channel message ID, slow channel message ID and data, tolerance violation, fast channel CRC error, slow channel CRC error, all CRC errors, pulse period error, successive sync pulses error (1/64) User-definable Manchester/NRZ (Option) Trigger on start of frame (SOF), bus value, and Manchester errors CXPI (Option) Trigger on the start of frame (SOF), the end of frame (EOF), PTYPE, frame ID, data and info frame ID, data and info frame ID (long frame), CRC field error, parity error, inter-byte space error, inter-frame space error, framing error, data length error, sample error, all errors, sleep frame, wakeup pulse USB PD (Option) Trigger on preamble, EDP, ordered sets, preamble errors, CRC errors, header content (control messages, data messages, extended messages and value in HEX) 1. Suspend, resume, reset, bit stuff error, and SE1 error are USB 2.0 low- and full-speed only. Performance Characteristics (Continued)

37 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Search, navigate, and lister Type Edge, pulse width, rise/fall, runt, frequency peak, serial bus 1, serial bus 2 Copy Copy to trigger, copy from trigger Frequency peak Source Math functions Max number of peaks 11 Control Threshold, excursion, results order (frequency or amplitude) Result display Event lister or navigation. Manual or autoscroll via navigation or touch event lister entry to jump to a specific event Waveform measurements DC vertical accuracy/cursors 2 Single cursor accuracy: ± [DC vertical gain accuracy + DC vertical offset accuracy + 0.21% full scale] Dual cursor accuracy: ± [DC vertical gain accuracy + 0.42% full scale] 1 Number of measurements 56 automatic measurements, maximum of 10 displayed at a time Cursors 2 pairs of XY cursors Automatic measurement of positions, ΔX, 1/ΔX, ΔY, and ΔY/ΔX Automatic measurements Measurements continuously updated with statistics. Cursors track last selected measurement. Select up to 10 measurements from the list below: Snapshot Makes a snapshot of 31 most popular measurements. Touchable target to populate the measurement side bar Voltage/current Peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, preshoot, average- N cycles, average-full screen, DC RMS-N cycles, DC RMS-full screen, AC RMS-N cycles, AC RMS-full screen (standard deviation), ratio-N cycles, ratio-full screen Time Period, frequency, counter, + width, - width, burst width, + duty cycle, - duty cycle, bit rate, rise time, fall time, delay, phase, X at min Y, X at max Y Count Positive pulse count, negative pulse count, rising edge count, falling edge count Mixed Area-N cycles, area-full screen Jitter Option DSOX6JITTER required Data TIE, clock TIE, N-period, period-period, + width to + width, - width to - width Real-time eye Option DSOX6JITTER required Eye width, eye height Dual-channel (requires N2820A probe) Charge-N cycles, charge-full screen, peak-peak, amplitude, DC RMS-N cycles, DC RMS-full screen, AC RMS- N cycles, AC RMS-full screen (standard deviation), average-N cycles, average-full screen, base Automatic measurement logging Available via BV0004B BenchVue Counter Built-in frequency counter (see “Precision counter/totalizer section” for the 10-digit counter) Source Any analog and digital channel Resolution 5 digits Max frequency 1 GHz (1.2 GHz typical) 1. D enotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and ± 10 °C from firmware calibration temperature. 2. 1 mV/div is a magnification of 2 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting. Performance Characteristics (Continued)

38 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Waveform math Number of math functions Four, displays all four simultaneously. Can be cascaded Arithmetic Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root, absolute value, common logarithm, natural logarithm, exponential, base 10 exponential, low-pass filter, high-pass filter, averaged value, magnify, max hold, min hold, measurement trend, chart logic bus (timing or state), clock recovery Enhanced FFT Record size Up to 1-Mpts resolution via precision mode Window types Hanning, flat top, rectangular, Blackman-Harris, Bartlett Display Color grade or monochrome Waveforms FFT, max hold, min hold, average Peak search Max 11 peaks, threshold and excursion control Waveform analysis Mask/limit test (Option) Standard mask/limit test capability provides pass/fail comparison of a signal under test to a predefined mask template or automask template. Predefined mask templates or edits to an automask template can be made via a text editor. > 130,000 mask tests per second (waveform update rate) Histogram Provides a statistical view of a waveform or a measurement Source Any analog channels, math functions, reference waveforms, measurements Types Horizontal, vertical, or measurement Measurements Hits, peak, max, min, peak to peak, mean, median, mode, bin width, standard deviation, 1~3 sigma Modes All modes supported except zoom, ZY, and roll Color grade Provides a 3-dimensional view of waveform intensity Source Any analog channels, math functions, reference waveforms, real-time eye Color themes Temperature and intensity Modes All modes supported except zoom, ZY, and roll Jitter (Option) Measures the variance of a measurement over time Jitter measurement floor 600 fs rms at 6 GHz sine wave (typical) Source Any analog channels, math functions, and reference waveforms Clock recovery Constant frequency, first-order phase lock loop (PLL), second-order PLL, explicit Data rate: Fully automatic, semi-automatic, manual Real-time eye (Option) Provides the color graded eye pattern analysis based on the recovered clock. Data bits are folded on top of each other per clock cycle to give a 3-dimensional view Source Any analog channels, math functions, and reference waveforms Clock recovery Constant frequency, first-order phase lock loop (PLL), second-order PLL, explicit Data rate: Fully automatic, semi-automatic, manual Color mode Color grade Measurements Eye height, eye width Precision mode Increase the analysis record length. Minimum: 100 kpts; maximum 1 Mpts Performance Characteristics (Continued)

39 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Precision counter/totalizer (Specifications are typical) (option) Counter Source Any analog channel or trigger qualified event Resolution 10 digits (8 digits for trigger qualified event) Max frequency Up to 3.2 GHz (4 GHz typical). With Hi-speed USB 2.0 decoding, 1 GHz (1.2 GHz typical) Trig-qual events 1/(trigger holdoff time) for trigger qualified events (max 25 MHz, minimum dead time of 40 ns) Measurement Frequency, period, totalize Totalizer Counter size 64-bit totalizing counter Edge Rise or fall Gating Positive or negative level. Select from analog channels except the source Time reference Internal or external 10 MHz reference clock Integrated digital voltmeter (Specification are typical) (option) Source Analog channels only (1 ~ 4) Functions ACrms, DC, DCrms, frequency Resolution ACV/DCV: 3 digits Counter frequency: 5.5 digits Measuring rate 100 times/second Auto ranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements Range meter Graphical display of most recent measurement, plus extreme over the previous 3 seconds Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Option) WaveGen outputs/ Output modes Two (front-panel BNC connectors) Both waveform generator outputs can be frequency tracked, amplitude tracked, or completely tracked. Phase adjustable. A generator’s output can be inverted to create a differential signal Output modes: Normal (continuous) or single-shot (limited to arbitrary, sine, ramp, sine cardinal, exp rise/fall, cardiac, Gaussian pulse) Waveforms Sine, square, ramp, pulse, DC, noise, sine cardinal (sinc), exponential rise, exponential fall, cardiac, Gaussian pulse, and arbitrary Modulation Modulation is available on channel 1 only. Modulation is not available when tracking mode is enabled Modulation types: AM, FM, FSK Carrier waveforms: sine, ramp, sine cardinal, exponential rise, exponential fall, and Cardiac.C176 Modulation source: Internal (no external modulation capability) AM: Modulation: Sine, square, ramp Modulation frequency: 1 Hz to 20 kHz Depth: 0 to 100% FM: Modulation: Sine, square, ramp Modulation frequency: 1 Hz to 20 kHz Minimum carrier frequency: 10 Hz Deviation: 1 Hz to carrier frequency or (2e12/carrier frequency), whichever is smaller FSK: Modulation: 50% duty cycle square wave FSK rate: 1 Hz to 20 kHz| Hop frequency: 2x FSK rate to 10 MHz 1. Only the following combination of wave shapes can be frequency tracked or completely tracked: a . Sine, ramp, sine cardinal, cardiac, and Gaussian pulse. b . Square wave, and pulse. c . Exponential rise and exponential fall. d . Arbitrary. Performance Characteristics (Continued)

40 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued) Sine Frequency range 0.1 Hz to 20 MHz Amplitude flatness ± 0.5 dB (relative to 1 kHz) Harmonic distortion –40 dBc Spurious (nonharmonics) –40 dBc Total harmonic distortion 1% SNR (50 Ω load, 500 MHz BW) 40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp < 0.1V) Square wave/pulse Frequency range 0.1 Hz to 10 MHz Duty cycle 20 to 80% Duty cycle resolution Larger of 1% or 10 ns Rise/fall time 19 ns (10 to 90%) Overshoot < 2% Asymmetry (at 50% DC) ± 1% ± 5 ns Jitter (TIE RMS) 500 ps Ramp/triangle wave Frequency range 0.1 Hz to 200 kHz Linearity 1% Variable symmetry 0 to 100% Symmetry resolution 1% Pulse Frequency range 0.1 Hz to 10 MHz Pulse width 20 ns minimum Pulse with resolution 10 ns Edge time Fixed at 19 ns (not variable) Overshoot < 2% Noise Bandwidth 20 MHz typical Sine cardinal (sinc) Frequency range 0.1 Hz to 1.0 MHz Exponential rise/fall Frequency range 0.1 Hz to 5.0 MHz Cardiac Frequency range 0.1 Hz to 200.0 kHz Gaussian pulse Frequency range 0.1 Hz to 5.0 MHz Arbitrary Waveform length 1 to 8,192 points Amplitude resolution 10 bits (including sign bit) 1 Repetition rate 0.1 Hz to 12 MHz Sample rate 100 MSa/s Filter bandwidth 20 MHz Frequency Sine wave and ramp accuracy 130 ppm (frequency < 10 kHz) 50 ppm (frequency > 10 kHz) Square wave and pulse accuracy [50 + frequency/200] ppm (frequency < 25 kHz) 50 ppm (frequency ≥ 25 kHz) Resolution 0.1 Hz or 4 digits, whichever is larger 1. Full resolution is not available at output due to internal attenuator stepping. Performance Characteristics (Continued)

41 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued) Amplitude Range: Minimum 20 mVpp if |offset| ≤ 0.5 Vpp into Hi-Z 1 10 mVpp if |offset| ≤ 0.5 Vpp into 50 Ω 1 Range: Maximum 10 Vpp except, 9 Vpp if sinc or cardiac, 7.5 Vpp if Gaussian pulse into Hi-Z; 5 Vpp/4.5 Vpp into 50 Ω Resolution 100 μV or 3 digits, whichever is higher Accuracy 1.5% (frequency = 1 kHz) DC offset Range ± 5 V into Hi-Z, except ± 4 V if sine wave, ± 2.5 V if sinc, cardiac, or Gaussian pulse into Hi-Z ± 2.5 V into Hi-Z, except ± 2 V if sine wave, ± 1.25 V if sinc, cardiac, or Gaussian pulse into 50 Ω Resolution Larger of 250 uV or 3 digits Accuracy (waveform modes) ± 1.5% of offset setting ± 1% of amplitude ± 1 mV Accuracy (DC mode) ± 1.5% of offset setting ± 3 mV Main output Impedance 50 Ω typical Isolation Not available, main output BNC is grounded Protection Overload automatically disables output Trigger output Trigger output available on trig-out BNC Quick action customization key Quick measure all Displays a popup containing a snapshot of all the single waveform measurements Quick measure statistics reset Resets all measurement statistics and the measurement count Quick mask statistics reset Resets mask statistics and counters Quick histogram statistics reset Zeros the histogram counters Quick print Print the current screen image Quick save Saves the current setup, screen image, or data file as specified in the settings menu Quick email Emails the current setup, screen image, or data file as specified in the settings menu Quick recall Recalls setup, mask, or reference waveform Quick freeze display Freezes the display without stopping running acquisitions or unfreezes the display if currently frozen. Waveform intensity preserved Quick trigger mode Toggles the trigger mode between auto and normal Quick clear display Clears the display Display characteristics Display 12.1-inch capacitive multi-touch/gesture enabled color TFT LCD Display mode Zone/zoom/annotation mode and waveform placement mode Resolution 800 (H) x 600 (V) pixel format (screen area) Graticules 8 vertical divisions by 10 horizontal divisions with intensity controls Format YT and XY Maximum waveform update rate > 135,000 wfm/s (real time) > 450,000 wfm/s (real time max update rate) Persistence Off, infinite, variable persistence (100 ms to 60 s) Intensity gradation 256 intensity levels 1. Sinc, cardiac and Gaussian pulse: ± 1.25 V into Hi-Z; ± 625 mV into 50 Ω. Performance Characteristics (Continued)

42 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Connectivity USB 2.0 hi-speed host port USB 2.0 hi-speed host ports x3, two front and one real panel. Supports memory devices, printers, keyboards, mice, and USB microphones USB 2.0 hi-speed device port One USB 2.0 hi-speed device port on rear panel. USB Test and Measurement Class (USBTMC) compatible LAN port 10/100/1000 Base-T port on rear panel. LXI IPv6 extended function Web remote control VNC Web interface (via major Web browsers) Video-out port VGA out on rear panel. Connect oscilloscope display to an external monitor or projector GPIB port N4865A GPIB-to-LAN adapter (option) 10-MHz reference BNC connector on the rear panel Support mode Output and input off, output on (10-MHz out) input on (10-MHz in) In mode 50 Ω, 356 mVpp to 4.48 Vpp (–5 dBm to 17 dBm), 6.32-Vpp max (20-dBm max) Recommended input signal accuracy: better than ± 10 ppm Out mode 50 Ω, 1.65 Vpp square wave Trigger out BNC connector on the rear panel. Supported modes: triggers, mask, waveform generator 1 sync pulse, and waveform generator 2 sync pulse General and environmental characteristics Power line consumption Maximum 200 W Power voltage range 100-120 V, 50/60/400 Hz; 100-240 V, 50/60 Hz ± 10% auto ranging Temperature Operating 0 to +50 °C Non-operating –40 to +70 °C Humidity Operating 90% RH (non-condensing) at 40 °C Non-operating 90% RH (non-condensing) at 65 °C Altitude Operating Up to 4,000 m (15,000 ft.) Non-operating Up to 15,300 m (50,000 ft.) Electromagnetic compatibility Meets EMC Directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN 61326-1:2006 Group 1 Class A requirement CISPR 11/EN 55011 IEC 61000-4-2/EN 61000-4-2 IEC 61000-4-3/EN 61000-4-3 IEC 61000-4-4/EN 61000-4-4 IEC 61000-4-5/EN 61000-4-5 IEC 61000-4-6/EN 61000-4-6 IEC 61000-4-11/EN 61000-4-11 Canada: ICES-001:2004 Australia/New Zealand: AS/NZS Safety UL61010-1 3rd edition, CAN/CSA_22.2 No. 61010-1-12, IEC61010-1 3rd edition Vibration Meets IEC60068-2-6 and MIL-PRF-28800; class 3 random Shock Meets IEC 60068-2-27 and MIL-PRF-28800; class 3 random; (operating 30 g, ½ sine, 11-ms duration, 3 shocks/axis along major axis, total of 18 shocks) Mean Time Before Failure (MTBF) > 120,000 hours Dimensions 425 mm W x 288 mm H x 148 mm D Weight Net: 6.8 kg (15 lbs.), Shipping: 11.3 kg (25 lbs.) Performance Characteristics (Continued)

43 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet Non-volatile storage Reference waveform display Four internal waveforms or USB thumb drive. Displays up to 4 reference waveforms simultaneously Data/file save Setup/image Setup (*.scp), 8 or 24-bit bitmap image (*.bmp), PNG 24-bit image (*.png) Waveform data CSV data (*.csv), ASCII XY data (*.csv), binary data (*.bin), lister data (*.csv), reference waveform data (*.h5), multichannel waveform data (*.h5), arbitrary waveform data (*.csv) Application data Mask (*.msk), power harmonics data (*.csv), USB signal quality (*.html and *.bmp) Analysis results (*.csv) Cursor data, measurement results, histogram statistics, mask test statistics, color grade bin, search, segmented timestamps Max USB flash drive size Supports industry standard flash drives Set ups without USB flash drive 10 internal setups Set ups with USB flash drive Limited by size of USB drive Included standard with oscilloscope Calibration Certificate of calibration, 2-year calibration interval Probe One per channel, N2894A 700-MHz passive probe (10:1 attenuation) N2756A 16-digital-channel MSO cable (1 per oscilloscope included on all MSO models and DSOX6MSO upgrade option) Interface language support/built-in help English, Chinese (simplified and traditional), French, German, Italian, Japanese, Korean, Portuguese, Russian, and Spanish localized front-panel overlays, interface, and built-in help system Voice control support English (American), English (British), English (Indian), Chinese Simplified (Mainland), Chinese Simplified (Cantonese), Chinese Traditional (Taiwan), Chinese Traditional (Cantonese), French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish (Latin America) and Spanish (Castilian) Power cord Localized power cord Front-panel protection Front-panel cover Documentation CD containing localized user’s guide, service guide, and programmer’s manual Related literature Publication title Publication number Jitter Analysis - Application Note 5991-4000EN Automotive Serial Bus Testing Using Keysight’s InfiniiVision X-Series and Infiniium S-Series Oscilloscopes - Application Note 5991-4038EN Physical Layer Testing of the USB 2.0 Serial Bus Using InfiniiVision 6000 X-Series and Infiniium Series Oscilloscopes - Application Note 5991-4167EN Evaluating Oscilloscopes for Low-Power Measurements - Application Note 5991-4268EN InfiniiVision and Infiniium Oscilloscopes - Product Fact Sheet 5991-4273EN Evaluating Current Probe Technologies for Low-Power Measurements - Application Note 5991-4375EN Performance Characteristics (Continued)

44 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA ®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. The business that became Keysight was a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials Download your next insight Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. – Electronic design automation (EDA) software – Application software – Programming environments – Productivity software

45 | Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2014 - 2017 Published in USA, November 7, 2017 5991-4087EN www.keysight.com Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—one- stop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/6000X For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System