DRD40 CHINFA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

www.chinfa.com sales@chinfa.com DRD40 SERIESl in r Preim a y Vo MODEL NO. INPUT VOLTAGE OUTPUT WATTAGE OUTPUT VOLTAGE OUTPUT CURRENT EFF. (typ.) EFF. (min.) MODEL LIST INPUT CURRENT (max.)(typ.) Characteristics Conditions min. typ. max. unit Isolation resistance Ambient temperature Input-Output, @ 500VDC Operating at Vi nom MΩ100 -40 o C+ 71 Derating (see derating curve) o % / C2.5o o Vi nom, from +51 C to +71 C Storage temperature Non operational + 85 o C-40 o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Switching frequency Vi nom, Io nom KHz100 Isolation voltage Input-Output 1,500 VDC 95Relative humidity Vi nom, Io nom Vi nom, Io min o Bellcore Issue 6 @40 C, GB % RH Temperature coefficient MTBF o % / C Hours Hours Hours Hours Hours ± 0.03 Altitude during operation m 576,000 560,000 568,000 580,000 605,000 4,850 IEC 60068-2-13 300 12V 15V 24V Dimension L91 x W53 x D56.5 mm Pollution degree 2 Installation position Vertical ( other direction may derating using ) Free air convectionCooling GENERAL Characteristics Conditions min. typ. max. unit Input voltage range 10 32 VDCTa min ... Ta max, Io nom No load input current mAVi nom, Io = 0 Input voltage w/o damage 40 VDCIo nom Startup voltage VDCIo nom 9.6 Input filter Pi type INPUT SPECIFICATIONS Single Output Models 10-32 VDC 1.6 A 3.8 ADRD40-05 + 5 VDC30 WATTS 6 A 81%79% 10-32 VDC 10-32 VDC 10-32 VDC 10-32 VDC 1.8 A 4.5 A

2.1 A 5 A

+ 9 VDC + 12 VDC + 15 VDC + 24 VDC

36 WATTS

40 WATTS

3.4 A 2.7 A 1.7 A 82% 84% 84% 85% 80% 82% 82% 83%

FEATURES

DC - DC DIN RAIL MOUNTABLE POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT ‧3:1 WIDE INPUT RANGE ‧SHORT CIRCUIT PROTECTION ‧INTERNAL INPUT FILTER ‧REMOTE ON / OFF ‧LOW PROFILE ‧3 YEARS WARRANTY EN 60950-1 a UL 60950-1 C US IND. CONT. EQ. UL 508 2016.05.25 P1

sales@chinfa.comwww.chinfa.com o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Characteristics Conditions min. unittyp. max. Vi nom, Io max % Minimum load Vi nom % Output voltage accuracy Line regulation % Load regulation Io nom, Vi min ...Vi max Startup time %± 1Vi nom, Io min ...Io nom Vi nom, Io nom ms50 ± 1 Transient recovery time ms Ripple & noise Power back immunity Capacitor load Vi nom, Io nom, BW = 20MHz Vi nom, Io nom Vi nom, Io nom mV 12V, 15V DC ON indicator threshold at start up (Green LED) Vi nom, Io nom Vi nom, Io nomDC LOW indicator threshold after start up (Red LED) Characteristics Conditions min. typ. max. unit 100 VDC7.5 3,500 1,000 Vi nom, 1~0.5 Io nom μ F μ F 0 +1 Voltage trim range Vi nom, 0.8 Io nom 5V 12V 15V 24V VDC VDC VDC VDC VDC 4.75 8.55 11.4 14.25 22.8 5.5 9.9 13.8 16.5 27.6 9V VDC15 12V VDC18 15V VDC22 24V VDC35 9V 2,200 μ F 24V 470 μ F 3.5 6.8 VDC VDC 4.5 8.1 9 VDC12V 10.8 19.2 3.5 6.8 19.2 4.5 8.1 10.8 VDC VDC VDC 13.5 21.6 VDC VDC VDC VDC 12V 15V 15V 24V 24V 13.5 21.6 Efficiency Vi nom, Io nom, Po / Pi Up to 85%, See model list and typ efficiency curve Vi nomRated continuous loading 5V 12V 15V 24V OUTPUT SPECIFICATIONS Rated over load protection Over voltage protection 110 145 %Vi nom (see typ current limited curve) Vi nom,0.8 Io nom (Auto Recovery) 5V 5.75 6.5 VDC 9V 10.35 11.7 VDC 12V 14.4 16.2 VDC 15V 17.25 19.5 VDC 24V 28.8 32.4 VDC Output short circuit Degree of protection IP20 Current limited (Auto-recovery) Input fuse Internal surge voltage protection T6.3A / 125VDC internal VaristorIEC 61000-4-5 Remote ON / OFF OFF : -0.3 ~ 2VDC applied, reference to input GND ON : opened or 8 ~ 10VDC applied, reference to input GND CONTROL AND PROTECTION 6 A @ 5Vdc / 5.4 A @ 5.5 Vdc 4 A @ 9Vdc / 3.6 A @ 9.9 Vdc 3.4 A @ 12Vdc / 2.9 A @ 13.8 Vdc 2.7 A @ 15Vdc / 2.4 A @ 16.5 Vdc 1.7 A @ 24Vdc / 1.45 A @ 27.6 Vdc 2016.05.25 P2

www.chinfa.com sales@chinfa.com CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safely and firmly on the rail; no tools required even to remove INSTALLATION Ventilation / Cooling Normal convection All sides 25m/m free space For cooling recommended Connector size range AWG24-12 (0.2~2.5mm ) flexible / solid cable -Connector can withstand torque at maximum 6 pound-inches. 7 m/m stripping at cable end recommends.o Use copper conductors only, 60/75 C GENERAL TOLERANCE ±0.30[0.01] ±0.50[0.02] DRD40 SERIES PIN NO. Designation Description 1, 2 3, 4 OUTIN + Positive output terminal - Negative output terminal OTHER DC ON Vout ADJ. DC LO Operation indicator LED Trimmer-potentiometer for Vout adjustment DC Low indicator LED ON / OFF Remote ON / OFF terminal Positive input terminal Negative input terminal 91.00 [3.58] 32.40 [1.28] 48.90 [1.93] 56.50 [2.22] 51.50 [2.02] 45.00 [1.77] 53.00 [2.09] 91.00 [3.58] DC LO Vout ADJ. DC ON 1234 + + 6 7 ON / OFF PHYSICAL CHARACTERISTICS 91 x 53 x 56.5 mm (3.58 x 2.09 x 2.22 inches)Case size PlasticCase material Packing 0.24kg ; 64 / 14kg / 2.28CUFT 180gWeight o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION UL / cUL TUV UL 508 EN 60950-1 CE EN 61000-6-3, EN 55022 Class B EN 61000-4-5, EN 61000-4-6, EN61000-4-8, ENV 50204, EN 61204-3 Vibration resistance Shock resistance APPROVALS AND STANDARDS meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) UL 60950-1CTUVUS EN 61000-6-2, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4 MECHANISM & PIN CONFIGURATION mm [inch] PIN ASSIGNMENT meet IEC 60068-2-6 (Mounting on rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) 2016.05.25 P3

sales@chinfa.comwww.chinfa.com DERATING CURVE CIRCUIT SCHEMATIC DRD40 SERIES ‧Block diagram for DRD40 series Vo - Vo +Vi + Fuse Switching Device Line Filter Rectifier Opto - Isolation Output Level Detection DC ON (Green LED) DC LO (Red LED) Opto - Isolation Over Voltage Detection Vi - Efficiency Vs Output Load DRD40-12 Efficiency Vs Input Voltage DRD40-12 Input Voltage (V) Efficiency [ % ] 14 16 18 22 24 26 28 30 3210 Io : Full Load Efficiency [ % ] 20 30 40 50 60 70 80 90 100 Output Load (%) Vi : 24VDC DERATING AND EFFICIENCY CURVE ON / OFF PWM controller Vout ADJ. Reference & Error Amp. o Temperature [ C ] 100 71-40 Power out [ % ] Input Voltage : >28V but 32V Safe Operating Area o Temperature [ C ] 100 71-40 Power out [ % ] Input Voltage : 10V ~ 28V Safe Operating Area 100 Power out [ % ] 80 o Ta : 50 C Input Voltage [ V ] Safe Operating Area 12 20 2016.05.25 P4