FEATURES

AC - DC DIN RAIL MOUNTABLE POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT ‧UL / cUL / TUV / CE ‧UNIVERSAL INPUT 85~264VAC ‧SHORT CIRCUIT PROTECTION ‧INTERNAL INPUT FILTER ‧2 YEARS WARRANTY MODEL NO. INPUT VOLTAGE OUTPUT WATTAGE OUTPUT VOLTAGE OUTPUT CURRENT + 5 VDC + 12 VDC + 24 VDC Single Output Models 85~264 VAC 85~264 VAC 85~264 VAC 85~264 VAC 6000 mA 2500 mA 1250 mA 625 mA EFF. (typ.) 77% 82% 83% 83% EFF. (min.) 79% 84% 86% 86%

30 WATTS

Switching frequency Vi nom, Io nom KHz Characteristics Conditions min. typ. max. unit Isolation resistance Ambient temperature Input-Output, @ 500VDC Operating at Vi nom MΩ100 -40 o C o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Storage temperature Non operational o C-40 95Relative humidity Vi nom, Io nom Vi nom, Io min o Bellcore Issue 6 @40 C, GB % RH20 Temperature coefficient MTBF Altitude during operation o % / C Hours Hours m ± 0.03 5V model 12V model 24V model 48V model Hours Hours Conditions min. typ. max. unit Isolation voltage Input-Output 3000 / 4242 VAC / VDC Input-FG VAC / VDC 135 Derating (see derating curve) o % / C2.5o o Vi nom, from +61 C to +71 C 551000 582000 588000 609000 sales@chinfa.comwww.chinfa.com 2011.02.14 + 71 + 85 Dimension Spring terminal type L90 x W40.5 x D114 mm Free air convectionCooling Pollution degree 2 GENERAL IND. CONT. EQ. UL 508 HR Class I, Div 2 HR UL 60950-1 EN 60950-1 a HR UL 1310 EN 61558-1 EN 61558-2-17 4850IEC 60068-2-13

sales@chinfa.comwww.chinfa.com 2011.02.14 DRAN30 SERIES Characteristics Conditions min. unittyp. max. Vi nom, Io max % Minimum load Vi nom % Output voltage accuracy (Adjusted before shipment) Line regulation %Io nom, Vi min ...Vi max Vi nom,

0.8 Io nom

+ 1 ± 0.5 5.5 Line frequency Vi nom, Io nom 63 Hz47 8.5 5.6 5.5 4.9 Inrush current Power dissipation Leakage current 20 / 40 A W W W W Vi : 115 / 230 VAC , Io nom Vi : 230 VAC, Io nom Input-Output Input-FG mA mA o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Characteristics Conditions min. typ. max. unit Characteristics Conditions min. unittyp. max. Turn on time ms ms Vi nom, Io nom Vi nom, Io nom with 3500 F CAPμ Ripple & noise mV50Vi nom, Io nom, BW = 20MHz Fall time Transient recovery time ms ms Vi nom, Io nom Vi nom, 1~0.5 Io nom VDC VDC DC ON indicator threshold at start up (Green LED) Vi nom, Io nom 3.5 9.0 VDC VDC Capacitor load Vi nom, Io nom 1000 2000 150 24V model 48V model 5V model 12V model 0.25 3.5 Load regulation %Vi nom, Io min ...Io nom ± 0.5 VDC VDC VDC Hold up time 20 / 30 msVi : 115 / 230 VAC , Io nom ms ms Vi nom, Io nom Vi nom, Io nom with 3500 F CAPμ 150 500 24V model 48V model 5V model 12V model 7.5 3500 24V model 48V model 5V model 12V model Efficiency Vi nom, Io nom, Po / Pi Up to 86%, See model list and typ efficiency curve Internal surge voltage protection VaristorIEC 61000-4-5 Input fuse T2A / 250VAC internal Rated over load protection 110 140 %Vi nom (see typ current limited curve) Power back immunity Vi nom, Io nom 1 second Rated continuous loading 24V model 48V model 5V model 12V model OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS 24V model 48V model 5V model 12V model 6 A @ 5Vdc / 5.4 A @ 5.5 Vdc 2.5 A @ 12Vdc / 2.1 A @ 14 Vdc 1.25 A @ 24Vdc / 1.05 A @ 28 Vdc 0.625 A @ 48Vdc / 0.54 A @ 55 Vdc CONTROL AND PROTECTION Vi : 115 / 230 VAC, Io nom Vi : 85 VAC, Io nom Input current Rated input current 800 Io nomRated input voltage VAC240100

264 VAC85AC in

21.6 4.5 10.8 μ F Absolute input max. range Ta min ... Ta max, Io nom

www.chinfa.com sales@chinfa.com 2011.02.14 o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Over voltage protection Vi nom, Io nom (Auto Recovery) Power Rdy (for 24V model only) Threshold voltage of contact closed (at start up) VDC VDC VDC VDC VDC 6.0 6.8 Characteristics Conditions min. typ. max. unit 24V model 48V model 5V model 12V model 15 16.5 30 33 60 66 DC ON Vout ADJ. N L 6 7 8 - - ++ Rdy 5 1234 40.50 [1.59] 90.00 [3.60] 114.00 [4.49] DRAN30 SERIES MECHANISM & PIN CONFIGURATIONmm [inch] CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safeIy and firmly on the rail. INSTALLATION Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range Spring terminal: 2 AWG24-14 (0.2~2mm ) flexible / solid cable, 10 m/m stripping at cable end recommendso Use copper conductors only, 60 / 75 C PHYSICAL CHARACTERISTICS 90 x 40.5 x 114 mm (3.6 x 1.59 x nches)4.49 iCase size PlasticCase material Packing 0.35 kg ; 40 / 15 kg / 2.16 CUFT 270 gWeight 18.8 19.6 Output short circuit Fold forward Degree of protection UL / cUL TUV EN 60950-1, CB scheme EN 61558-1, EN 61558-2-17 (meet EN 60204-1) CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 CCC GB4943, GB9254, GB17625.1 Vibration resistance Shock resistance APPROVALS AND STANDARDS CONTROL AND PROTECTION IP20 UL 508 Listed UL 60950-1, UL 1310 Class 2 Power (only 5V w/o Class 2) Recognized ISA 12.12.01(Class I, Division 2, Groups A, B, C and D) meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) GENERAL TOLERANCE ±0.30[0.01] ±0.50[0.02]

‧Block diagram for DRAN30 series DRAN30 SERIES Fig. 1 Rdy connection RL > 700ohm a ) Relay Rdy Rdy - Vout - Vout 2.2K 0.5W 5.1V 0.3W b ) 5V signal TYP. CURRENT LIMITED CURVE DERATING CURVE o Temperature [ C ] 100 71-40 Power out [ % ] TYP. EFFICIENCY CURVE DRAN30-24 DRAN30-24 Power out [ % ] 10 10025 EFFICIENCY [ % ] 7550

230 Vac

115 Vac

Output Voltage [ % ] 100 130 140 150 160 170 180 190 www.chinfa.com sales@chinfa.com 2011.02.14 INOTHER OUT PIN NO. Designation Description DC OK output for relay (not connect except 24V model) Positive output terminal Positive output terminal Negative output terminal Negative output terminal Ground this terminal to minimize high-frequency emissions Input terminals (neutral conductor, no polarity at DC input) Input terminals (phase conductor, no polarity at DC input) Operation indicator LED Trimmer-potentiometer for Vout adjustment RDY N L Vout ADJ. DC ON 120 Note: 1) for 24V Model Only Vo - Vo + Vout ADJ. DC ON (Green LED)1) RDY (Open Collector) L N Fuse Switching Device Line Filter Inrush Current Limiter and Rectifier Rectifier Opto - Isolation Opto - Isolation Output Level Detection Reference & Error Amp. Over Voltage Detection Y Y Y PWM Controller Output Current [ % ]

AC - DC DIN RAIL MOUNTABLE POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT www.chinfa.com sales@chinfa.com 2011.02.14 MODEL LIST + 12 VDC + 24 VDC Single Output Models 85~264 VAC 85~264 VAC 85~264 VAC 2500 mA 1250 mA 625 mA 84% 86% 86% 82% 83% 83% MODEL NO. INPUT VOLTAGE OUTPUT WATTAGE OUTPUT VOLTAGE OUTPUT CURRENT EFF. (typ.) EFF. (min.) + 5 VDC85~264 VAC 6000 mA 79%30 WATTSDRAN30-05A 77% DRAN30 SERIES Switching frequency Vi nom, Io nom KHz Characteristics Conditions min. typ. max. unit Isolation resistance Ambient temperature Input-Output, @ 500VDC Operating at Vi nom MΩ100 -40 o C o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Storage temperature Non operational o C-40 95Relative humidity Vi nom, Io nom Vi nom, Io min o Bellcore Issue 6 @40 C, GB % RH20 Temperature coefficient MTBF o % / C Hours Hours ± 0.03 5V model 12V model 24V model 48V model Hours Hours Conditions min. typ. max. unit Isolation voltage Input-Output 3000 / 4242 VAC / VDC Input-FG VAC / VDC 135 Derating (see derating curve) o % / C2.5o o Vi nom, from +61 C to +71 C 551000 582000 588000 609000 + 71 + 85 Dimension Screw terminal type L90 x W40.5 x D114 mm Altitude during operation m Free air convectionCooling Pollution degree 2 GENERAL IND. CONT. EQ. UL 508 HR Class I, Div 2 HR UL 60950-1 EN 60950-1 a HR UL 1310 EN 61558-1 EN 61558-2-17 4850IEC 60068-2-13 ‧UL / cUL / TUV / CE ‧UNIVERSAL INPUT 85~264VAC ‧SHORT CIRCUIT PROTECTION ‧INTERNAL INPUT FILTER ‧2 YEARS WARRANTY

Line frequency Vi nom, Io nom 63 Hz47 8.5 5.6 5.5 4.9 Inrush current Power dissipation Leakage current 20 / 40 A W W W W Vi : 115 / 230 VAC , Io nom Vi : 230 VAC, Io nom Input-Output Input-FG mA mA Characteristics Conditions min. typ. max. unit 24V model 48V model 5V model 12V model 0.25 3.5 Vi : 115 / 230 VAC, Io nom Vi : 85 VAC, Io nom Input current Rated input current 800 Io nomRated input voltage VAC240100 Absolute input max. range DRAN30 SERIES Characteristics Conditions min. unittyp. max. Vi nom, Io max % Minimum load Vi nom % Output voltage accuracy (Adjusted before shipment) Line regulation %Io nom, Vi min ...Vi max Vi nom, + 1 ± 0.5 5.5 o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Characteristics Conditions min. unittyp. max. Turn on time ms ms Vi nom, Io nom Vi nom, Io nom with 3500 F CAPμ Ripple & noise mV50Vi nom, Io nom, BW = 20MHz Fall time Transient recovery time ms ms Vi nom, Io nom Vi nom, 1~0.5 Io nom DC ON indicator threshold at start up (Green LED) Vi nom, Io nom Capacitor load Vi nom, Io nom 1000 2000 150 Load regulation %Vi nom, Io min ...Io nom ± 0.5 VDC VDC VDC Hold up time 20 / 30 msVi : 115 / 230 VAC , Io nom ms ms Vi nom, Io nom Vi nom, Io nom with 3500 F CAPμ 150 500 24V model 48V model 5V model 12V model 7.5 3500 24V model 48V model 5V model 12V model Efficiency Vi nom, Io nom, Po / Pi Up to 86%, See model list and typ efficiency curve Internal surge voltage protection VaristorIEC 61000-4-5 Input fuse T2A / 250VAC internal Rated over load protection 110 140 %Vi nom (see typ current limited curve) Power back immunity Vi nom, Io nom 1 second Rated continuous loading 24V model 48V model 5V model 12V model OUTPUT SPECIFICATIONS 24V model 48V model 5V model 12V model 6 A @ 5Vdc / 5.4 A @ 5.5 Vdc 2.5 A @ 12Vdc / 2.1 A @ 14 Vdc 1.25 A @ 24Vdc / 1.05 A @ 28 Vdc 0.625 A @ 48Vdc / 0.54 A @ 55 Vdc CONTROL AND PROTECTION www.chinfa.com sales@chinfa.com 2011.02.14 Vi nom Rise time VDC VDC VDC VDC VDC VDC 3.5 9.0 VDC VDC 21.6 4.5 10.8 μ F INPUT SPECIFICATIONS Ta min ... Ta max, Io nom

www.chinfa.com sales@chinfa.com 2011.02.14 DC ON Vout ADJ. N L 6 8 - - ++ Rdy 40.50 [1.59] 90.00 [3.60] 114.00 [4.49] 1234 o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION Over voltage protection Vi nom, Io nom (Auto Recovery) Power Rdy (for 24V model only) VDC VDC VDC VDC 6.0 6.8 Characteristics Conditions min. typ. max. unit 24V model 48V model 5V model 12V model 15 16.5 30 33 60 66 DRAN30 SERIES MECHANISM & PIN CONFIGURATIONmm [inch] PHYSICAL CHARACTERISTICS 90 x 40.5 x 114 mm (3.6 x 1.59 x nches)4.49 iCase size PlasticCase material Packing 0.35 kg ; 40 / 15 kg / 2.16 CUFT 270 gWeight Output short circuit Fold forward Degree of protection UL / cUL TUV EN 60950-1, CB scheme CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 CCC GB4943, GB9254, GB17625.1 Vibration resistance Shock resistance APPROVALS AND STANDARDS CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safeIy and firmly on the rail. INSTALLATION Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range Screw terminal: 2 AWG26-12 (0.2~2.5mm ) flexible / solid cable, connector can withstand torque at maximum 5 pound-inches. 4~5 m/m stripping at cable end recommendso Use copper conductors only, 60 / 75 C IP20 CONTROL AND PROTECTION UL 508 Listed UL 60950-1, UL 1310 Class 2 Power (only 5V w/o Class 2) Recognized ISA 12.12.01(Class I, Division 2, Groups A, B, C and D) EN 61558-1, EN 61558-2-17 (meet EN 60204-1) meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) GENERAL TOLERANCE ±0.30[0.01] ±0.50[0.02] Threshold voltage of contact closed (at start up) 18.8 19.6 VDC

‧Block diagram for DRAN30 series Note: 1) for 24V Model Only Fig. 1 Rdy connection RL > 700ohm a ) Relay Rdy Rdy - Vout - Vout 2.2K 0.5W 5.1V 0.3W b ) 5V signal PIN ASSIGNMENT DRAN30 SERIES INOTHER OUT PIN NO. Designation Description DC OK output for relay (not connect except 24V model) Positive output terminal Positive output terminal Negative output terminal Negative output terminal Ground this terminal to minimize high-frequency emissions Input terminals (neutral conductor, no polarity at DC input) Input terminals (phase conductor, no polarity at DC input) Operation indicator LED Trimmer-potentiometer for Vout adjustment RDY N L Vout ADJ. DC ON TYP. CURRENT LIMITED CURVE DERATING CURVE o Temperature [ C ] 100 71-40 Power out [ % ] TYP. EFFICIENCY CURVE DRAN30-24A DRAN30-24A Power out [ % ] 10 10025 EFFICIENCY [ % ] 7550 Output Current [ % ] Output Voltage [ % ] 100 130 140 150 160 170 180 190 www.chinfa.com sales@chinfa.com 2011.02.14 120 Note: 1) for 24V Model Only Vo - Vo + Vout ADJ. DC ON (Green LED)1) RDY (Open Collector) L N Fuse Switching Device Line Filter Inrush Current Limiter and Rectifier Rectifier Opto - Isolation Opto - Isolation Output Level Detection Reference & Error Amp. Over Voltage Detection Y Y Y PWM Controller