FEATURES

AC - DC DIN RAIL MOUNTABLE BATTERY CHARGER INDUSTRIAL CONTROL EQUIPMENT www.chinfa.com sales@chinfa.com MODEL NO. INPUT VOLTAGE OUTPUT WATTAGE OUTPUT VOLTAGE OUTPUT CURRENT + 13.6 VDC + 27.2 VDC + 13.6 VDC + 27.2 VDC Single Output Models 90~264 VAC 90~264 VAC 90~264 VAC 90~264 VAC 2.5 A 1.25 A 4.5 A 2.5 A EFF. (typ.) 86% 88% 86% 88% EFF. (min.) 84% 86% 84% 86%

34 WATTS

61 WATTS

68 WATTS

12 : 13.6V OUT / 24 : 27.2V OUT ‧UNIVERSAL INPUT 90~264VAC ‧SHORT CIRCUIT PROTECTION ‧INTERNAL INPUT FILTER ‧2 YEARS WARRANTY ‧CHARGER FOR LEAD-ACID BATTERIES ‧BATTERY POLARITY PROTECTION Switching frequency Vi nom, Io nom KHz Isolation resistance Ambient temperature Input-Output, @ 500VDC Operating at Vi nom MΩ100 -40 o C+ 51 Storage temperature Non operational + 85 o C-40 95Relative humidity Vi nom, Io nom Vi nom, Io min o Bellcore Issue 6 @40 C, GB % RH20 Temperature coefficient MTBF 10050 o % / C± 0.03 Hours Hours Hours Hours 30W 12V model 24V model 60W 12V model 24V model Isolation voltage Input-Output 3000 / 4242 VAC / VDC 668000 688000 568000 588000 Characteristics Conditions min. typ. max. unit o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION mAltitude during operation 4850 L91 x W90 x D57 mmDimension Free air convectionCooling GENERAL a IEC 60068-2-13 2011.01.27

Characteristics Conditions min. typ. max. unit Ta min ... Ta max, Io nom

264 VAC90

Line frequency Vi nom, Io nom 63 Hz47 Inrush current Leakage current 30 / 60 A W W Vi : 115 / 230 VAC , Io nom Input-Output mA Vi : 115 /230 VAC, Io nom Vi : 90 VAC, Io nom Input current Rated input current Io nomRated input voltage VAC100 240 Power dissipation Vi : 230 VAC, Io nom 30W model 60W model 5.5 10.9 0.25 680 / 430 mA mA mA mA 30W model 30W model 60W model 60W model Rdy off: Threshold after start up 24V model 12V model VDC VDC7 Over voltage protection Vi nom, Io nom (Shut down protection) 24V model 12V model VDC VDC15 Characteristics Conditions min. typ. max. unit Vi nom, Io max % Minimum load Vi nom % Output voltage accuracy Line regulation % Load regulation Vi nom, Io nom %Vi nom, Io min ...Io nom Io nom, Vi min ...Vi max ± 1 Characteristics Conditions min. unittyp. max. Hold up time 10 / 30 msVi : 115 / 230 VAC , Io nom DC ON indicator threshold at start up (Green LED) Vi nom, Io nom Ripple & noise Power back immunity mV100 Vi nom, Io nom Rise time Fall time Transient recovery time ms ms 150 VDC VDC7 Turn on time 1800 Vi nom, Io nom ms150 Vi nom, Io nom 24V model 12V model 24V model 12V model o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION DBR30/60W SERIES Input fuse T2A / 250 VAC internal Internal surge voltage protection VaristorIEC 61000-4-5 Rated over load protection 105 110 %Vi nom Power Rdy Rdy on: Threshold at start up 24V model 12V model VDC VDC10 www.chinfa.com sales@chinfa.com Vi nom, 1~0.5 Io nom Vi nom, Io nom, BW = 20MHz VDC VDC ± 1 ± 1 Degree of protection Battery polarity protection Output short circuit Hiccup mode IP20 Yes CONTROL AND PROTECTION OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS ms 2011.01.27 Absolute input max. range

CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 Vibration resistance Shock resistance meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) www.chinfa.com sales@chinfa.com 90.00 [3.54] 91.00 [3.58] 32.25 [1.27] 49.00 [1.93] 57.00 [2.24] 52.50 [2.07] 45.00 [1.77] MECHANISM & PIN CONFIGURATION mm [inch] CONSTRUCTION Easy snap-on mounting onto the DIN-Rail (TS35/7.5 or TS35/15), unit sits safely and firmly on the rail; no tools required even to remove INSTALLATION Ventilation / Cooling Normal convection All sides 25m/m free space For cooling recommended Connector size range AWG24-12 (0.2~2.5mm ) flexible / solid cable -Connector can withstand torque at maximum 6 pound-inches. 7m/m stripping at cable end recommends.o Use copper conductors only, 60/70 C PHYSICAL CHARACTERISTICS 91 x 90 x 57 mm (3.58 x 3.54 x 2.24 inches)Case size PlasticCase material Packing 0.33kg ; 40 / 14kg / 2.28CUFT 270gWeight o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed SPECIFICATION GENERAL TOLERANCE ±0.30[0.01] ±0.50[0.02] DBR30/60W SERIES DC ON DBR30-24 BAT FAIL APPROVALS AND STANDARDS 2011.01.27 LVD EN 60950-1

www.chinfa.com sales@chinfa.com DBR30/60W SERIES TYP. CURRENT LIMITED CURVE Output Current [ % ] Output Voltage [ % ] 100 95 100 105 110 115 120 CIRCUIT SCHEMATIC ‧Block diagram for DBR30/60W series Vo - Vo +L N Fuse Switching Device Line Filter Inrush Current Limiter and rectifier Rectifier Opto - Isolation Output Level Detection Reference & Error Amp. DC ON(Green LED) PFM Controller BAT FAIL(Red LED) RDY(Relay Contact) PIN ASSIGNMENT PIN NO. Designation Description OUTINOTHER 1, 2 RDY A normal open relay contact for DC ON level control - Negative output terminal3 + Positive output terminal4

5 L Input terminals (phase conductor, no polarity at DC input)

6 N Input terminals (neutral conductor, no polarity at DC input)

Battery reverse indicator LED P42011.01.27