Features

Plug-in design• Shorting spring on mounting plate for pre-installation continuity • check Captive mounting screw• Torx screw for tamper resistance• Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115• Automatic selection of 12- or 24-volt operation at 15 and 15/75 • candela Minimal intrusion into the back box• Rotary switch for tone selection• Two volume settings• Electrically compatible with existing SpectrAlert products• Listed for ceiling or wall mounting• SpectrAlert Advance selectable-output chimes and chime/ strobes are private mode notification appliances used to alert trained personnel to investigate possible emergency situations and to take appropriate action. Security guard and nurse workstations are ideal locations for chime products. SpectrAlert Advance chimes and chime/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance Series of notification appliances is designed to simplify your installations, with features such as plug-in designs, instant feedback messages to ensure correct installation of individual devices, and seven field-selectable candela settings for chime/ strobes. More specifically, when installing SpectrAlert Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon, single-gang, or double-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the chime or chime/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device is rotated into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captive mounting screw. SpectrAlert Advance products allow you to choose:

  • 12 or 24 volts
  • At 24 volts, 15, 15/75, 30, 75, 95, 110, or 115 candela by way of rear- mounted slide switch and front view window
  • Select chime tones and volume using a simple rotary switch Selectable Output Chimes and Chime/Strobes SpectrAlert® Advance selectable-output chimes and chime/strobes are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:188 (chime/strobes) 7125-1653:189 (chimes)S4011

SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance chimes and chime/strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, single-gang 2 × 4 × 17/8-inch back box, or double-gang back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Chime/ strobes shall have field-selectable candela settings of 15, 15/75, 30, 75, 95, 110 and 115. Chime/Strobe Combination The chime/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and UL 464. The chime/strobe shall comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The chime shall have two audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. Synchronization Module The module shall be a System Sensor Sync•Circuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and chimes at temporal three. Also, while operating the strobes, the module shall silence the chimes on chime/strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage Range2 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) Input terminal wire gauge 12 to 18 AWG Chime/strobe dimensions (including lens) 5.6 in L × 4.7 in W × 2.5 in D (142 mm L × 119 mm W × 64 mm D) Chime dimensions 5.6 in L × 4.7 in W × 1.3 in D (142 mm L × 119 mm W × 33 mm D) BBS-2 (red back box skirt) 5.9 in L × 5.0 in W × 2.2 in D (151 mm L × 128 mm W × 56 mm D) BBSW-2 (white back box skirt) 5.9 in L × 5.0 in W × 2.2 in D (151 mm L × 128 mm W × 56 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2. CHS products will operate at 12 V nominal only for 15 and 15/75 cd.

Setting Repetition Rate dB Level 1 1 Second Chime High 2 1 Second Chime Low 3 ¼ Second Chime High 4 ¼ Second Chime Low

5 Temporal Chime High

6 Temporal Chime Low

9 One Test Chime/coded High

UL Max. Chime Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR

1 Second Chime High 34 50 58 51

1 Second Chime Low 30 51 51 54

¼ Second Chime High 34 51 50 50 ¼ Second Chime Low 31 51 50 52 Temporal Chime High 30 50 48 54 Temporal Chime Low 30 47 50 51

5 Second Whoop High 32 52 34 54

5 Second Whoop Low 30 40 34 52

Coded High 48 49 50 50 * Chime and Chime/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 1 Second Chime High 58 59 61 61 2 1 Second Chime Low 53 54 55 55 3 ¼ Second Chime High 63 64 66 66 4 ¼ Second Chime Low 58 59 60 60

5 Temporal Chime High 62 64 68 69

6 Temporal Chime Low 55 57 60 60

7 5 Second Whoop High 68 71 75 77 8 5 Second Whoop Low 62 64 67 68

9 One Test Chime/coded High 57 55 51 57

Chime tone selection is accomplished by using the rotary switch on the back of the product. The current draw and sound measurements for various chime tone settings are listed below. UL Max. Chime/Strobe Current Draw (mA RMS) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115

1 Second Chime High 131 142 65 76 94 160 185 207 213

1 Second Chime Low 131 142 64 75 92 157 183 203 212

1/4 Second Chime High 129 142 66 75 95 159 184 205 212 1/4 Second Chime Low 129 142 64 74 91 155 181 204 211 Temporal Chime High 125 142 64 74 91 156 181 205 211 Temporal Chime Low 129 141 65 75 92 155 180 200 209

5 Second Whoop High 133 145 70 81 99 165 189 210 217

5 Second Whoop Low 130 143 66 77 95 160 186 206 214

One Time Chime * 127 141 64 76 93 156 182 203 210 FWR Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115

1 Second Chime High 128 150 72 82 98 158 183 202 210

1 Second Chime Low 127 150 71 81 97 157 182 202 210

1/4 Second Chime High 129 149 72 82 99 160 183 203 211 1/4 Second Chime Low 128 149 71 81 97 154 179 196 205 Temporal Chime High 128 148 71 81 97 157 179 199 206 Temporal Chime Low 125 147 71 81 97 156 180 200 206

5 Second Whoop High 136 152 84 93 110 170 193 212 220

5 Second Whoop Low 132 150 77 86 102 161 184 203 214

One Time Chime * 127 147 72 82 97 157 181 200 210 *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. *Chime/Strobes cannot be powered with a coded supply.

3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0396-003 • 12/07 • #1890 SpectrAlert Advance Dimensions Model Description CHR Chime, Red CHW Chime, White CHSR Chime/Strobe, Red CHSW Chime/Strobe, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White SpectrAlert Advance Ordering Information 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝4.7˝ 5.6˝ 1.3˝ 5.0˝ 2.2˝ 5.9˝ Chime Chime/Strobe BBS-2/BBSW-2 CHSR Red Chime Strobe CHSW White Chime Strobe CHR Red Chime CHW White Chime