ORIGINAL INSTRUCTIONS DL0323 INSTRUCTIONS OPERATION & MAINTENANCE 12V BATTERY/ALTERNATOR TESTER MODEL NO: CBAT2 PART NO: 6260106
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SAFETY INSTRUCTIONS 1. Clarke International are not liable for any damages or consequences resulting from:
- Connection and installation errors. Damage to the device due to mechanical influences or voltage surges or any modification to the device. Any unauthorized manipulation to the product which would lead to cancellation of the guarantee. Use of the device for purposes other than described in this instruction manual. Any influenc e of fluids. 2. DO NOT use the device in a moist or wet environment. 3. DO NOT use the tester close to flammable materials. 4. DO NOT use the tester in an explosive environment. 5. Make sure the device is alwa ys positioned in a safe place. The device must be placed out of reach of children. DO NOT expose the device to direct sunlight or other heat source. 6. Store the tester in a safe, dry place after use. 7. DO NOT try to use other cables with this product. WARNING: HIGH VOLTAGES ARE PRESENT AT THE FOLLOWING POINTS: - THE IGNITION COILS, DISTRIBUTOR CAP, IGNITION CABLE, SPARK PLUGS. CAUTION: PLEASE READ THESE INSTRUCTIONS AS WELL AS THOSE IN YOUR VEHICLE HANDBOOK VERY CAREFULLY BEFORE USING THE TESTER, KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 8. DO NOT open the case, contains no replaceable parts inside the product. 9. If the device malfunctions, please consult your dealer. 10. DO NOT use the device while the vehicle is in motion, the tester is not suitable for permanent installation in a motor vehicle. 11. Make sure the vehicle is se curely parked and the handbrake applied before using the tester. For vehicles with automatic transmissions the “park position” must be engaged and the hand brake must be engaged. 12. DO NOT use other measuring devices when using the tester. 13. Seek professional help if you ar e unsure about anything related to the electrical system in your vehicle. 14. When using the crocodile clips fo r testing, the red clip must be clamped to the positive pole (+ or Red) of the battery, and the black clip must be clamped to the negative pole (- or black). DO NOT reverse the connections. 15. If the outer insulation of the cable is damaged, it may cause a short circuit. Stop using it immediately and contact your Clarke dealer. OTHER INFORMATION 1. The Battery Tester is suitable for all types of 12V lead acid batteries (vehicle batteries). 2. The device is NOT suitable for commercial purposes. 3. The device is NOT calibrated.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DISPLAY IDENTIFICATION
1 LCD Display Screen 7 Alternator Test Indicator -
2 Battery Test Indicator - Lo w 8 Battery Test Start Button
3 Battery Test Indicator -
9 Alternator Test Start Button
4 Battery Test Indicator - High 10 12V Cigarette Lighter Test
5 Alternator Test Indicator -
11 Crocodile Clips Test Lead
6 Alternator Test Indicator -
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com OPERATION FUNCTION DESCRIPTION 1. Testing of all 12V vehicle lead-acid batteries. 2. Shows real-time voltage and batte ry charge with the results shown as LOW/MID/FULL. 3. Test charging system with th e results shown as LOW/OVER/ CHARGE, and displays the charging voltage in real time. 4. Two options available for connecting: Directly plug into the vehicles 12V cigarette lighter socket. Connect directly to the batte ry terminals with attached crocodile clips test lead. 5. Protection of reverse polarity connection and over-current, with built in fuse. PRECAUTIONS 1. DO NOT test a battery within a short period of time after charging or use, as the result maybe inaccurate. 2. Perform the test when the battery is in a cold state, when the voltage is stable. 3. Make sure all electrical equipm ent is turned off when testing. 4. Keep the vehicle stationary during testing. DO NOT test while the vehicle is being driven. BATTERY TEST 1. Make sure that the vehicle ig nition is in the off position. 2. Connect the tester to the batte ry via the crocodile clips or cigarette lighter test lead and the battery voltage value will be shown on the LED screen. Testing with the Crocodile Te st Lead: Connect the red clamp to the positive (+/red) terminal on the car battery, then connect the black clamp to the negative (-/black) terminal.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com Testing with the Cigarette Lighte r Test Lead: Insert the cigarette lighter test lead into the 12V DC cigarette lighter socket of the vehicle. 3. Turn off all electrical equipm ent and wait for the voltage to stabilize. 4. Press the Battery button to enter th e battery test function. This will show on the LED screen the voltage value and the test result. If the LOW light is on, it means t hat the battery power is very low and needs to be charged as soon as possible. Voltage: <11.8V. If the MID light is on, it means the battery power is lower and needs to be charged. Voltage: <11.8V MID <12.5V If the FULL light is on, it means the battery is fully charged. Voltage: >12.5V 5. Once completed, remove the black clamp from the negative (-/black) terminal on the car battery then remove the red clamp from the positive (+/red) terminal or unplug the cigarette lighter test lead. CHARGING SYSTEM (ALTERNATOR) CHECK 1. Connect the tester to the batte ry via the crocodile clips or cigarette lighter test lead and the battery voltage value will be shown on the LED screen. Testing with the Crocodile Test Lead: Connect the red clamp to the positive (+/red) terminal on the car battery, then connect the black clamp to the negative (-/black) terminal. Testing with the Cigarette Lighte r Test Lead: Insert the cigarette lighter test lead into the 12V DC cigarette lighter socket of the vehicle. 2. Start the engine and keep the ve hicle out of gear or in neutral 3. Turn off all electrical equipm ent, including headlights, air- conditioning, glass heating, etc. 4. Increase the engine speed to 2500RPM or above. 5. Press the Alternator button to enter the charging system test mode. At this time the LED screen will show the charging voltage value and the test result.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com If the OVER light is on, it me ans that the alternator output voltage is high. Voltage >15V If the LOW light is on, it means that the alternator output voltage is low. Voltage: <13.5V If the CHARGE light is on, it means the charging system is normal. Voltage: <13.5 CHARGE < 15V 6. Once completed, remove the black clamp from the negative (-/black) terminal on the car battery then remove the red clamp from the positive (+/red) terminal or unplug the cigarette lighter test lead. MAINTENANCE CLEANING Before cleaning, disconnect th e device from the electrical system. DO NOT use any liquid cleaning product. DO NOT use any inflammable cleaning product. DO NOT submerge the device or spill any liquids over it. If needed, clean the device wi th a light, damp, soft cloth.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SPECIFICATION Product Description Alternator and Battery Tester Part number 6260106 Operating Temp. Range -20c - 70c Input Voltage 6V -25V (12V System) Measurement (H x W x D) 110 x 60 x 15 mm Product Weight 130g Compatible Battery Types 12V Lead Acid Batteries: WET (Flooded) MF (Maintenance Free) EFB (Enhanced Flooded) AGM (Absorbed Glass Mat) GEL VRLA (Valve Regulated Lead Acid) Lead Calcium SLA (Sealed Lead Acid) 12V LiFePO4 (Lithium Iron Phosphate)
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY - UKCA
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY - CE