OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS DL0722 - ISS 3 VENTILATION FAN MODEL NO: CAM200B, 250B & 300B PART NO: 3230442, 3230452 & 3230462

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE Ventilation Fan which is designed for indoor use in an industrial environment. Read this manual carefully, in doing so you guarantee the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. SAFETY RULES Make sure that you read, understand and comply with the following rules. POSITIONING

  • This fan is designed for indoor use only.  Be aware that the suction capability is considerable. Do not position the fan where it will blow dust, chips or hazardous fumes at people.  DO NOT place the fan close to any wet surface. DO NOT place against any surface such as a wall, door or furniture etc.  DO NOT place the fan on a raised su rface or anywhere it could topple over.  Only use the fan in a level position.  Take care to ensure that the intake grille cannot be blocked by curtains or other fabrics. Do not allow loose clothing, long hair, jewellery etc. to be drawn into the intake side of the fan.  Do not operate the fan in explosive atmospheres such as in the presence of flammable liquids, gasses or dust such as in a paint spray booth. Electric motors create sparks which may ignite dust or fumes.  DO NOT cover the fan or obstruct the air inlet and outlet sections of the ventilator.  DO NOT get the fan wet or use in areas of high condensation.  DO NOT allow the power cable to touch hot surfaces.  Do not use this fan with a progra mmable timer used to switch it on automatically. PERSONNEL SAFETY  DO NOT use the fan when you are tired or under the influence of alcohol, drugs or intoxicating medication.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com  DO NOT stand on the fan.  DO NOT use the fan with wet hands or when there is water on the power cable.  Young children must be kept away unless continuously supervised. ELECTRICAL SAFETY  Inspect the power cabl e / plug for damage/looseness. Do not use the fan if the power cable is damaged.  Make sure that the voltage on the product label is the same as the voltage of the power supply. If in doubt, consult a qualified electrician.  Do not abuse the electrical cable. Do not use the cable for pulling or unplugging the fan.  Keep the cable away from sources of heat, oil, sharp edges or moving parts. Damaged or tangled cables increase the risk of electric shock.  Do not use extension cables with this fan. SERVICE & REPAIRS  Check that the fan is in good work ing order. Take immediate action to have it repaired or any damaged parts replaced.  DO NOT attempt to repair the fan yo urself. Always contact the Clarke service department who will use recommended parts only. Unapproved parts may be dangerous and will invalidate your warranty. ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be discarded with general household waste but according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognized disposal facility. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused, tampered with, or not used for the purpose for which it was intended. Faulty goods must be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ELECTRICAL CONNECTIONS Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage. This product may be fitted with a non-rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or damaged, the plug must not be used until a suitable replacement is obtained. If the plug has to be changed because it is not suitable for your socket, or due to damage, it should be cut off and a replacement fitted, following the wiring instructions shown below. The old plug must be disposed of safely, as insertion into a mains socket could cause an electrical hazard. If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug, proceed as follows.  The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Black.  The wire which is coloured Brown must be connected to the terminal which is marked L or coloured Red.  The wire which is coloured Yellow and Green must be connected to the terminal which is marked E or or coloured Green. We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD) If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself. WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY. WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: Blue = Neutral Brown = Live Yellow and Green = Earth Plug must be BS1363/A approved. Always fit a 10 Amp fuse. Ensure that the outer sheath of the cable is firmly held by the clamp Neutral (Blue) Live (Brown) Earth (Green and Yellow)

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CONNECTING DUCTWORK These ventilation fans will be used with Clarke retractable ducting available in 5 metre lengths as follows. 1. Before use, attach the ducting to the discharge end of the ventilation fan as shown, secured with the tie cord provided. 2. Place the ventilation fan in a level position on a flat surface and at a safe distance from flammable materials. 3. The ventilation fan is operated by the ON/OFF switch located under the handle. 4. Connect the ventilation fan to a suitable power supply. MAINTENANCE  Clean the with a soft damp cloth, Do not use solvents or abrasives.  If used in spaces with high dust content, clean the guards and fan blades by vacuuming or wiping. Remove the end guard to gain access to the blades.  REPLACE GUARDS BEFORE RE-C ONNECTING TO MAINS SUPPLY.  No other maintenance is required, should you discover any problem with the ventilation fan return it to the Clarke service department for repair. To fit model Diameter Part No CAM200B 8” 3230443 CAM250B 10” 3230453 CAM300B 12” 3230463 WARNING: ALWA YS DISCONNECT FROM THE POWER SUPPLY BEFORE PERFORMING ANY CLEANING OR MAINTENANCE TASKS. THIS SHOULD BE CARRIED OUT BY THE CLARKE SERVICE DEPARTMENT.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com FAILURE TO OPERATE SPECIFICATIONS Problem Possible Cause Remedy Fan does not operate although plugged in with the switch on Plug is loose/bad connection Pull the plug out & check the connection of the plug and socket Fuse blown or circuit breaker trips Replace if necessary and investigate cause. If fuse blows repeatedly, consult your Clarke dealer No power at socket outlet Insert the plug in a functioning power socket Abnormal noise Fan is not level Stand fan on a level surface Model CAM200B CAM250B CAM300B Air Inlet Size 8 inch 10 inch 12 inch Power supply 230V/50Hz 230V/50Hz 230V/50Hz Air Output: (m 3/h) 1500 m3/h 2700 m 3/h 3900 m 3/h Total Pressure 245 Pa 295 Pa 385 Pa Duty Cycle Classification: S1 (continu ous) S1 (continuous) S1 (continuous) Electrical Insulation Class I I I Product Weight 9.4 kg 11.2 kg 15.3 kg Sound Pressure Level 65 dB(A) 71 dB(A) 74.1 dB(A) Rpm 2800 2800 2800 Rated pressure 1.2 MP a 1.2 MPa 1.2 MPa Rated flow rate 879 m 3/h 1698 m 3/h 2379 m 3/h Rated motor input power 180W 300W 500W Specific Ratio (EU no 327/2011) 0.805 0.88 0.83

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY