Mini-spectrometer RC series Compact and low cost, OEM model (C9409MA) C9407MA, C9409MA PRELIMINARY DATA Jan. 2007 HAMAMATSU mini-spectrometer RC series is a compact polychromator integrated with a reflection grating and a CMOS linear image sensor. Two models are available: a mini-spectrometer module (C9407MA) equipped with a driver circuit, and a mini-spectrometer head (C9409MA) for OEM applications, which contains an optical system and an image sensor in a tiny case measuring only 28 × 28 × 28 mm. Light guided into the mini-spectrometer head is dispersed into to a spectrum which is then photoelectrically converted and output as video signals. The mini-spectrometer module has a USB port that connects to a PC for spectrum data collection. The mini-spectrometer module comes supplied with free sample software that allows setting measurement conditions, acquiring and saving data, and displaying graphs. Driver software and DLL are also supplied as accessory items to allow the users to configure their own measurement software. Features Applications /K6C Installation into measurement equipment /K6C Chemical measurement /K6C Visible light source testing /K6C Color measurement, etc. /K6C OEM model /K6C Integrating optical system and image sensor into a compact case: 28 × 28 × 28 mm /K6C Low cost C9409MA (Head) /K6C Integrating spectrometer head and drive circuit /K6C Spectral measurement using PC /K6C No external power supply required: USB bus power /K6C A/D conversion: 16-bit /K6C Wavelength conversion factor *1 is recorded in internal memory. C9407MA (Module) I Selection guide Product No. Product type Spectral response range (nm) Spectral Resolution (nm) Interface Light input method C9407MA RC-VIS-MOS (Module) 340 to 780 9 USB1.1 fiber C9409MA RC-VIS-MOS (Head) 340 to 780 9 - fiber *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. Calculation factor for converting the A/D converted count into the input light intensity is not provided. Structure of C9409MA C9409MA is offered in small size, low-cost units achieved by integrating optical components into a glass body. The reflec- tive grating mounted on the glass body is a plastic-molded replica grating. GRATING IMAGE SENSOR FOCUSING FUNCTIONCOLLIMATING FUNCTION GLASS BODY FIBER SLIT KACCC0348EB I Optical component layout C9409MA OEM model
Mini-spectrometer RC series C9407MA, C9409MA 14 28 320 FLEXIBLE BOARD(2 ×) M2.6 DEPTH 5 I Optical characteristics RC-VIS-MOS RC-VIS-MOSParameter C9407MA (Spectrometer module) C9409MA (Spectrometer head) Unit Spectral response range 340 to 780 nm Spectral resolution Max. (Spectral response half width)*2 9 nm Wavelength reproducibility *3 ±0.5 nm Wavelength temperature dependence 0.05 nm/°C Spectral stray light *2 *4 -30 dB Broadband stray light *2 *5 -25 dB *2: Depends on the slit opening. Values were measured with the slit listed in the table “ I General ratings / Absolute maximum ratings”. *3: Measured under constant light input conditions. *4: When light at 550 nm is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured in a region of the input wavelength ±40 nm. *5: The ratio of the transmittance in the transmitting wavelength region of an optical filter (OG530) to that in the blocking region. I Electrical characteristics Parameter C9407MA (Spectrometer module) C9409MA (Spectrometer head) Unit A/D conversion 16 - bit Integration time 5 to 10000 - ms Interface USB1.1 - - I General ratings/Absolute maximum ratings Parameter C9407MA (Spectrometer module) C9409MA (Spectrometer head) Unit Dimensions 73 (W) × 53 (D) × 46 (H) 28 (W) × 28 (D) × 28 (H) mm Built-in head C9409MA - - Image sensor CMOS linear image sensor (S8378-256N) - Number of pixels 256 pixels Slit *6 70 (H) × 550 (V) µm Optical NA 0.22 - Fiber core diameter 600 µm Optical fiber connector SMA905 - Operating temperature *7 +5 to +40 °C Storage temperature -20 to +70 °C *6: Entrance slit aperture size of the incorporated image sensor. *7: No condensation C9409MA I Dimensional outlines (unit: mm) C9409MA C9409MA(4 ×) M2.6 DEPTH 3 50.011.5 73.0 340 30.011.5 53.0 C9407MA KACCA0147EC KACCA0149EC OEM model OEM model OEM model
Mini-spectrometer RC series C9407MA, C9409MA I Connection example (transmission light measurement) Light to be measured is guided into the entrance port of RC series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable mea- surement are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup. USB CABLE PC MINI- SPECTROMETER C9407MA QUARTZ CELL (For holding liquid sample) FIBER VISIBLE FIBER LIGHT SOURCE (Halogen lamp) KACCC0260EB I Light input method For C9407MA and C9409MA, an SMA connector (plug) is attached with the other end of the optical fiber. Light can be easily guided by hooking up this connector to the SMA recep- tacle of an external unit. If the optical fiber connected to C9407MA and C9409MA is shorter than needed, an optical fiber of the desired length can be added by connecting a relay unit. I Electrical connection with a external circuit (C9409MA) The flexible printed circuit board protruding from the head or module is used make electrical connections to an external circui t. 4 ± 0.5 6 ± 0.5 THICKNESS: 0.3 Unit: mm 10.5 ± 0.2 KACCC0261EA
- Mating connectors: FH12-20S-0.5SV vertical type [Made by HIROSE electric] FH12 52745-2090 horizontal type [Made by MOLEX]Pin No. Te rm in al name I/O Discription Pin No. Te rm in al name I/O Discription NC - No connection NC - No connection NC - No connection GAIN I Gain setting NC - No connection A.GND - Analog GND EOS O EOS (end of scan) signal A.GND - Analog GND A.GND - Analog GND ST I Sensor scan start signal A.GND - Analog GND CLK I Sensor scan sync signal H-CMOS compatible VIDEO O Video signal output SDA O Thermosensor output signal A.GND - Analog GND SCL I Thermosensor driver signal A.GND - Analog GND D.GND - Digital GND +5 V I Power supply of image sensor: +5 V VCC I Power supply of thermosensor: +3.3 V SMA CONNECTOR (PLUG) C9409MA Note: Refer to the “CMOS linear image sensor S8377/S8378 series” datasheet for information on the operating conditions.
Mini-spectrometer RC series C9407MA, C9409MA I Dedicated software (C9407MA) Installing the dedicated software package (containing sample software, device driver, DLL) *10 into your PC allows running the following basic tasks:
- Measurement data acquisition and save
- Measurement condition setup
- Module information acquisition (wavelength conversion factor, polychromator type, etc)
- Graphic display
- Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: This product cannot operate with the software that comes with the mini-spectrometer TM or TG series. *10: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1 or later) Device driver and DLL for controlling hardware are also provided. You can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic *11. The DLL provides functions such as USB port open/close, measurement condition setup, measurement data and module information acquisition. *11: Operation of the device driver and DLL has been verified only with Microsoft Visual C++ ® and Visual Basic®. Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries. I Measurement examples (1) White LED and 3-color LED measurements (C9407MA) KACCB0100EA (2) Reflected light from color paper (C9407MA) Relative reflectance with 100 % being equal to reflectance of white plate WAVELENGTH (nm) AD COUNT 340 35000 30000 25000 20000 15000 10000 5000 390 440 490 540 590 640 790 690 740 WHITE LED 3-COLOR LED WAVELENGTH (nm) RELATIVE REFLECTANCE (%) 340 100 390 440 490 540 590 790 640 690 740 BLUE GREEN RED KACCB0102EA I Accessories (C9407MA)
- USB cable
- Dedicated software (sample software, device driver, DLL)
Mini-spectrometer RC series C9407MA, C9409MA HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K. Cat. No. KACC1136E01 Jan. 2007 DN 5 Type No. Type Spectral resolution Max. (nm) Image sensorSpectral response range (nm) C10082CA C10082CAH C10082MD C10083CA C10083CAH C10083MD C9404CA C9404CAH C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB TM-UV/VIS-CCD TM-VIS/NIR-CCD TM-VIS/NIR-CCD TM-VIS/NIR-MOS TG-UV-CCD TG-UV-MOS TM-UV/VIS-CCD TM-UV/VIS-MOS High sensitivity TG-SWNIR-CCD TG-SWNIR-MOS TG-cooled NIR-I TG-NIR TG-UV-CCD TG-cooled NIR-II TM seriesTG seriesTG series (λ=320 to 900 nm) (λ=320 to 900 nm) (λ=550 to 900 nm) (λ=550 to 1100 nm) Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor NMOS linear image sensor InGaAs linear image sensor 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Type No. Type Image sensorSpectral response range (nm) C9409MA RC-VIS-MOS 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 OEM model Spectrometer head C9407MA RC-VIS-MOS Spectrometer module * Typ. 340 to 780 340 to 780 1100 to 2200 900 to 1700 500 to 1100 320 to 1000 200 to 400 200 to 800 /K6E Mini-spectrometer line-up Non-cooled type Low noise (cooled type) Low noise (cooled type) Spectral resolution Max. (nm) High resolution Wide dynamic range High resolution Wide dynamic range High sensitivity High resolution Wide dynamic range Wide dynamic range High sensitivity High sensitivity RC series RC series