Features
/K6C Integrated with back-thinned type CCD image sensor: Sensitivity is about two orders of magnitude higher than CMOS types. /K6C High resolution 1 nm (C9404CAH) /K6C High throughput due to transmission grating made of quartz /K6C Highly accurate optical characteristics /K6C Easy to install into equipment /K6C Wavelength conversion factor is recorded in internal memory *1
Applications
/K6C Low-light-level measurement such as fluorescence measurement /K6C Detection of saccharic acids in foods /K6C Taste analyzers /K6C Evaluation of light source characteristics such as UV light source MODULE High sensitivity type (integrated with back-thinned type CCD image sensor) C9404CA, C9404CAH, C9405CA Mini-spectrometer TG series TG series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Light to be measured is guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. C9404CA, C9404CAH and C9405CA are high sensitivity mini-spectrometers employing a back-thinned type CCD image sensor. Their sensitivity is about two orders of magnitude higher than CMOS types making them even more ideal for low-light- level measurement. C9404CAH is high resolution type (resolution: 1 nm Typ.). Their products come supplied with free sample software that allows setting measurement conditions, acquiring and saving data, and displaying graphs. Driver software and DLL are also supplied as accessory items to allow the users to configure their own measurement software. PRELIMINARY DATA Jan. 2007 I O ptical characteristics TG-UV-CCD TG-SW NIR- CCDParameter C9404CA C9404CAH C9405CA Unit Spectral response range 200 to 400 500 to 1100 nm Spectral resolution Max. (Spectral response half width) * 2 3 1 * 3 5 * 4 nm Wavelength reproducibility * 5 ±0.1 ±0.2 nm Wavelength temperature dependence 0.02 nm/°C Spectral stray light * 2, *6 -35 dB I Electrical characteristics Parameter Speci fication Unit A/D conversion 16 bit Integration tim e 10 to 10000 ms Interface USB1.1 - USB bus power current consumption 100 mA External power supply 5 V I General ratings / Absol ut e max i mum r at i ngs Parameter Speci fication Unit Dimensions 125.7 (W ) × 115.7 (D) × 75 (H) mm Image sensor Back-t hi nned type CCD image sensor (S10420-1006) - Number of pixels 1024 pixels Slit * 7 (H) × (V ) 140 × 500 10 × 1000 70 × 800 µ m Optical NA 0.11 0.22 - Connector for optical fiber SMA905D - Operating temperature * 8 +5 to +40 °C Storage temperature -20 to +70 °C *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor for converting the A/D converted count into the input light intensity is not provided. *2: Depends on the slit opening. Values were measured with the slit listed i n the table “ I General ratings /Absol ute maximum ratings”. *3: Typical *4: λ =550 to 900 nm *5: Measured under constant light input conditions *6: W hen monochromatic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured in a region of the input wavelength ±20 nm (C9404CA, C9404CAH) or ±40 nm (C9405CA). C9404CA, C9404CAH: 300 nm, C9405CA: 800 nm *7: Entrance slit aperture size *8: No condensation I Output comparison 200 300 500400 600 700 900800 1000 1100 WAVELENGTH (nm) 10-5 10-4 10-3 10-2 10-1 101 100 RELATIVE SENSITIVITY * C9404MC (CMOS TYPE) 200 to 400 nm C9405MC (CMOS TYPE) 500 to 1100 nm C9404CA (CCD TYPE) 200 to 400 nm C9404CAH (CCD TYPE) 200 to 400 nm C9405CA (CCD TYPE) 500 to 1100 nm * A/D count when constant light level enters fiber. (Typ. Ta=25 ˚C) KACCB0157EA I Measurable optical power * Intensity of light incident on mini-spectrometer through slit is constant. (λ=300 nm, Integration time 10 to 10000 ms) 10-15 10-13 10-11 10-9 10-7 LIGHT INTENSITY * (W) C9404CA (CCD TYPE)C9404CA (CCD TYPE) C9404MC (CMOS TYPE) Comparison of CCD type and CMOS type KACCB0158EA
Mini-spectrometer TG series C9404CA, C9404CAH, C9405CA WAVELENGTH (nm) AD COUNTS 100 1000 10000 200 250 300 350 400 100000 C9404CA C9404CAH ENTRANCE SLIT FOCUSING LENS IMAGE SENSOR COLLIMATING LENS TRANSMISSION GRATING USB CABLE AC ADAPTER PC MINI- SPECTROMETER QUARTZ CELL (For holding liquid sample) FIBER HIGH POWER UV-VIS FIBER LIGHT SOURCE (Deuterium lamp and Halogen lamp) L10290 I Connection example (transmission light measurement) Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources al- lows a flexible measurement setup. KACCC0355EA I Optical component layout TM series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical charac- teristics. KACCC0256EA I Spectral resolution vs. wavelength WAVELENGTH (nm) SPECTRAL RESOLUTION (nm) 200 300 400 500 600 700 800 900 1100 (Typ. Ta=25 ˚C) 1000 C9405CA (Slit width 70 µm, Optical NA 0.22) C9404CA (Slit width 140 µm, Optical NA 0.11)C9404CAH (Slit width 10 µm, Optical NA 0.11) KACCB0160EA I Measurement example Line spectra from low-pressure mercuy lamp were mea- sured with C9404CA (TG-UV-CCD), C9404CAH (TG-UV- CCD). KACCB0166EA
Mini-spectrometer TG series C9404CA, C9404CAH, C9405CA 125.7 115.7 75.0 I Dimensional outline (unit: mm) KACCA0202EA I Dedicated software package (supplied with unit) Installing the dedicated software package (containing sample software, device driver, DLL)*9 into your PC allows running the following basic tasks:
- Measurement data acquisition and save
- Measurement condition setup
- Module information acquisition (wavelength conversion factor, polychromator type, etc.)
- Graphic display
- Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: T wo or more mini-spectrometers can be connected and used with one PC simultaneously. *9: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1a or later) Device driver and DLL for controlling hardware are also provided. Y ou can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic.*
10 The DLL provides functions such as USB port open/close, measurement condition setup, measurement
data and module information acquisition. *10: Operation of the device driver and DLL has been verified only with Microsoft Visual C++ ® and Visual Basic®. Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries.
Mini-spectrometer TG series C9404CA, C9404CAH, C9405CA HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K. Cat. No. KACC1131E01 Jan. 2007 DN Type No. Type Spectral resolution Max. (nm) Image sensorSpectral response range (nm) C10082CA C10082CAH C10082MD C10083CA C10083CAH C10083MD C9404CA C9404CAH C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB TM-UV/VIS-CCD TM-VIS/NIR-CCD TM-VIS/NIR-CCD TM-VIS/NIR-MOS TG-UV-CCD TG-UV-MOS TM-UV/VIS-CCD TM-UV/VIS-MOS High sensitivity TG-SWNIR-CCD TG-SWNIR-MOS TG-cooled NIR-I TG-NIR TG-UV-CCD TG-cooled NIR-II TM seriesTG seriesTG series (λ=320 to 900 nm) (λ=320 to 900 nm) (λ=550 to 900 nm) (λ=550 to 1100 nm) Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor CMOS linear image sensor NMOS linear image sensor InGaAs linear image sensor 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Type No. Type Image sensorSpectral response range (nm) C9409MA RC-VIS-MOS 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 OEM model Spectrometer head C9407MA RC-VIS-MOS Spectrometer module * Typ. 340 to 780 340 to 780 1100 to 2200 900 to 1700 500 to 1100 320 to 1000 200 to 400 200 to 800 /K6E Mini-spectrometer line-up Non-cooled type Low noise (cooled type) Low noise (cooled type) Spectral resolution Max. (nm) High resolution Wide dynamic range High resolution Wide dynamic range High sensitivity High resolution Wide dynamic range Wide dynamic range High sensitivity High sensitivity RC series RC series I Accessories
- USB cable
- Dedicated software (sample software, device driver, DLL)
- AC adapter (for power supply) I Options (sold separately) Optical fibers for light input Type. No Product name Applicable mini-spectrometer Core diameter (µm) Specification A9762-01 Fiber for UV/visible range (resistance to UV) C9404CA (TG-UV-CCD) C9404CAH (TG-UV-CCD) 600 A9763-01 Fiber for visible/near infrared range C9405CA (TG-SWNIR-CCD) 600 N.A.=0.22, length 1.5 m, connectorized SMA905D at both ends