Dimensions ( W × H × D ) Weight Input Voltage Input Current Output Voltage Output Current Current Fluctuation (p-p) Current Drift at + 25 °C Heater Voltage Heater Current Warm-up Time Trigger Voltage With Load Without Load Output Voltage Output Current Operation Storage 160 300 – 15 0.5 –0.1 See below See below 25 – 5 600 – 50 0 to +40 -40 to +60 V A Max. V dc Typ. V dc Min. mA % Max. %/h Max. s V peak mm kg
20 CFM of Forced Air Cooling
100 × 118 × 36.2 0.17 24 – 2.4 (dc) M7628 Unit 113 × 122 × 220 2.7 90 to 115 / 180 to 250 (ac) ( Automatic) DEUTERIUM LAMP
RELATED PRODUCTS
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. © 2000 Hamamatsu Photonics K.K. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. HEATER VOLTAGE AND CURRENT Warm-up Voltage (V dc) Current (A dc) Operation Applicable LampsType Number C7860/M7628-2510 C7860/M7628-2517A C7860/M7628-3000A C7860/M7628-1035A C7860/M7628-1070 C7860/M7628-1555 A NOTE: A C7860 series are manufactured only when the order is placed. 2.5 – 0.15 2.5 – 0.15 3 – 0.15 10 – 0.5 10 – 0.5 15 – 0.75 0.8 1.2 0.5 Voltage (V dc) Current (A dc) 1 – 0.05 1.7 – 0.1 3.5 – 0.2 7 – 0.35 5.5 – 0.3 1.8 3.3 0.3 0.3 L6565, L7293, L7303, L6999, L7307, L7174 L7297, L7298, L6303, L6304, L7304, L7306 L6566, L6305, L6306 L7291, L7294, L6307, L6308, L7292 L7296, L7295, L6309, L6310 L6311, L6312
FEATURES
n Designed based on EN/UL standard (M7628) The C7860 designed based on EN standard only. n Constant Current Power Supply POWER SUPPLY C7860/OEM POWER SUPPLY M7628 Left: C7860, Right: M7628
DEUTERIUM LAMP POWER SUPPLY C7860/M7628 SERIES TLSOA0057EA TLSOA0061EA n Dimensional Outline (Unit: mm) 1. High voltage is used to operate the lamp. Use extreme caution to prevent electric shocks. 2. The guarantee period will be one year after shipment. The area of guarantee is limited to replacement of the faulty lamp. Faults resulting from natural disasters and incorrect usage will also be excluded from guarantee. Precautions When Using Deuterium Lamps 102 7.7 118 36.2 MAX. 1.5 6.2 86.47 100 28.5 9.58.1 #6-32 SCREW TERMINALS, 8 PLACES 4-M3 MAXIMUM COMPONENT HEIGHT POSITION DEUTERIUM LAMP (1) ANODE (2) APERTURE (3) HEATER (4) GROUND (GND) (5) +24 VDC ±10 % (6) +24 RETURN (GND) (7) +5 VDC (+) (8) +5 RETURN (-) DISABLE INPUT CIRCUIT DISABLE FUNCTION DISABLE = +5 V BETWEEN PINS 7 & 8 POLARITY AS INDICATED, LOAD = 2 mA ENABLE = 0 V BETWEEN PINS 7 & 8 OR PINS 7 & 8 OPEN OPTO COUPLER 1.8 k INPUT POWER DISABLE These product conforms to SAFETY/ EN61010-1 of the European Union. The M7628 is recognized upon UL 1950 (File No.191652). 200113 122 FRONT VIEW SIDE VIEW TOP VIEW REAR VIEW C7860 M7628
NOTE: A A8087 cable should be necessary for connection between C7860 series and E8039.
APPLICATIONS
n Light sources in various experiments n Light sources in spectrophotometry n High Safety, Interlock Function n No Optical Alignment Required n Easy Replacement of Optional Parts DEUTERIUM LAMP HOUSING E8039 Parameter Suitable Lamp Lamp Power Consumption Spectral Distribution Anode Current Tube Drop Voltage Material Dimension Optical Axis Height Optional Parts SMA Fiber Guide Adaptor with Lens (for thin diameter fiber) Collimating Lens (Material: Fused Silica, Dimension: 10 mm, Focal Point: 20 mm, Light output: collimating) Power Supply C7860 series, Connection cable A8087 and Lamp L6999-51 are optional. L2D2 L6999-51 Approx. 30 185 to 400 300 Fused Silica 72 (include feet height) Forced Air Cooling (Built-in cooling fan) 0 to +40 +5 to +35 30 to 90 120 × 107 × 140 (exclude projection part) Approx. 2.3 C7860-2510 A Lamp Output Window Cooling Function Operating Ambient Temperature Recommended Operating Temperature Operating Humidity Dimensions ( W × H × D ) Weight Suitable Power Supply Type No. Description/Value W nm V dc Typ. mA dc mm mm mm kg Unit This lamp housing was designed to allow easy operation of deuterium lamps such as L2D2 lamps and provide full lamp performance. It accommodates a lamp with a flange so that no optical alignment is required. The built-in interlock and forced-air cooling functions ensure high safety. Collimating lenses and fiber guide adaptors are also available as easy-to-replace options, which easily attach to the light exit and allow obtaining the desired light beam. Compact case allows easy handling and installation. Lamp housing design allows the L2D2 lamp to fully achieve its highly stable operation (fluctuation(p-p) within 0.05%). The interlock function turns off the lamp if the cover comes off. The surface temperature of the lamp housing is maintained below +50 °C. Designed to accommodate an L2D2 lamp with a flange which eliminates arc point shift. Absolutely no optical alignment is required over the life of the lamp or when replacing the lamp. As easy-to-replace options, collimating lenses and fiber guide adaptors that easily attach to the light exit are available, allowing you to obtain the desired light beam.
DEUTERIUM LAMP HOUSING E8039 TLSO1036E03 OCT. 2000 IP Printed in Japan (1000) TLSOA0062EA n Dimensional Outlines (Unit: mm) 1. High voltage is used to operate the lamp. Use extreme caution to prevent electric shocks. 2. The guarantee period will be one year after shipment. The area of guarantee is limited to replacement of the faulty lamp. Faults resulting from natural disasters and incorrect usage will also be excluded from guarantee. Precautions When Using Deuterium Lamps 1409 ARC POINT OUTPUT WINDOW LAMP REPLACEMENT PORT 1079.5 120 HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it HOMEPAGE URL http://www.hamamatsu.com